Overhead Bare Conductor ACSR Bear

China 
                        Overhead Bare Conductor ACSR Bear
                      manufacture and supplier

Overhead Bare Conductor ACSR Bear image

Get Latest Price Request a quote

Quick Details

Overhead Bare Conductor ACSR Bear

Yifang

AAC

ISO, CCC, CE

Aluminum

Round Wire

Bare

DC Cable

Super-high Voltage Cable

Overhead, Power Station

Yifang

Wooden Drum, Steel-Wooden Drum, Steel Reel

China

Product Details

Overhead Bare Conductor ACSR bear

Productor description:

1.Aluminum conductor and Alumum Alloy Conductor 
(1). All aluminium conductor (AAC) 
(2). All aluminimum alloy conductor(AAAC) 
(3). Aluminum conductor steel reinforced (ACSR) 
(4). Anti-corrosion type ACSR 
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW) 
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE) 
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR) 

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204. 
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182. 
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied. 
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels. 

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 
(AAAC) Conductor as per ASTM-B-399-1992 
(AAAC) Conductor as per BS-3242-1970 
(AAAC) Conductor IS: 398-IV-1994 
(ACSR) as per ASTM-B-233-1992 
(AAC) as per BS-215-1-1970 
(AAC) as per IS-398-1: 1976 
(AAC) as per ASTM-B-231-1990 
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 
(ACSR) BS-215-II-1970 
(AACSR) as per IEC-1089-1191 

AAC(All aluminum conductor) are suited for overhead power line. 

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. 

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power. 

Applications: 
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Construction: 
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. 

Specifications: 
ACSR bare conductor meets or exceeds the following ASTM specifications: 
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes 
B-231 Aluminum Conductors, Concentric-Lay-Stranded 
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) 
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) 

Notes: 
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

What are Aluminium Conductors used for?

Aluminium Conductors are predominantly used in Overhead Line applications and for primary and secondary power distribution. 

The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. The advantage of ACSR is that it has high tensile strength and is lightweight, which means over longer spans it needs less supports. ACSR is available with varying percentages of steel core to achieve different strengths. One of the advantages of this conductor in particular is that the desired strength can be achieved without a loss of ampacity. 

AAC is used mainly in urban areas where the spacing is short and the supports are closer together. The advantage of AAC conductors is that they have a high degree of corrosion resistance; for this reason they are used extensively in coastal areas. AAC Conductors were developed as a consequence of the galvanic corrosion that ACSR conductors are susceptible to. 

AAAC is used as bare overhead conductor for power transmission and distribution lines on aerial circuits that require larger mechanical resistance than AAC. AAAC also has better sag characteristics and a better strength to weight ratio than AAC. AAAC Cables have lower weight per unit length and slightly lower resistance per unit length than ACSR.

What is the difference between ACSR, AAC and AAAC Conductors?

The biggest difference between AAC, AAAC, and ACSR conductors are the materials they are constructed from. AAC is manufactured from electrolytically refined aluminium with a 99.7% minimum purity, AAAC is made from an Aluminium alloy, and ACSR contains a combination of Aluminium reinforced with Steel. 

The second factor that differentiates the three cables is their resistance to corrosion, which is important for the longevity of the cable. ACSR has a poorer resistance to corrosion, as it contains steel, which is prone to rust. AAAC and AAC have a better corrosion resistance, due to the fact that they are largely or completely aluminium. 

In an ACSR the galvanised steel core carries the mechanical load and the high purity aluminium carries the current. These utilise the lower thermal expansion coefficient of steel compared to aluminium, which the aluminium based conductors AAC and AAAC are unable to do.

What do ACSR, AAC and AAAC Conductors have in common?

ACSR, AAC and AAAC are all used in overhead line applications, and although for different specific applications, they are all involved in power distribution.

 Bare conductors are designed and manufactured according to customer’s special request .

 

We are China Overhead Bare Conductor ACSR Bear manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular AAAC Conductor Products

IEC61089 10-100 mm2

Power Transmission Lines AAAC Overhead Line Bare Conductor

Factory Direct ISO Transmission Line Bare Conductor All Aluminum Alloy Conductor AAAC

300mm Bare AAAC Conductor

All Aluminum Alloy Conductor AAAC Bare Conductor with ASTM BS Standard

Electric Wire Cable Overhead AAAC Aluminium Alloy Conductor

Popular AAC Conductor Products

Low-Voltage Overhead Bare Stranded All Aluminum AAC Conductor

Overhead Transmission AAC AAAC ACSR Bare Aluminum Conductor

625mm2 AAC All Aluminum Stranded Overhead Bare Conductor

Overhead All Aluminm Conductor AAC Conductor Price

AAC All Aluminum Conductor Types of 120mm2 Electric Conductors AAC

Stranded Conductor 16mm2 All Aluminum Bare Conductor AAC

Popular ACSR Conductor Products

IEC Standard Bare 250mm2 ACSR Conductor Overhead Conductor

USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Ruddy

Jyxl2015jl01 Jl Jl/G1a ACSR Aluminum Stranded Conductor and Aluminum-Steel Conductor Cable Low

USA Sizes ASTM B232 Overhead Conductor Steel Reinforced ACSR Cuckoo

ACSR Conductor Hawk

ISO Transmission Distribution Line Bare Conductor ACSR

Popular yifangcable Products

5-46kv Utility Shielded Power Cable Icea S-97-682

33kv 1core 150mm2 Awa Copper Cable

AS/NZS 1429 Copper XLPE Power Cable Copper Shielded Cable Armoured Cable

Thhn Core Green Insulated Ground Cable Aluminum Conductor XLPE Insulation Aluminum Alloy Interlocked Armour Cable

Low/Medium/High Voltage Al/Cu Conductor Cable

36kv XLPE Armor Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION