10kv Copper Conductor Steel Tape Armored Electric XLPE Insulation Open Air, Conduit, Duct PVC Cable
10kv Copper Conductor Steel Tape Armored Electric XLPE Insulation Open Air, Conduit, Duct PVC Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Medium Voltage Cable
1. Application
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.
2. Structure:
1. Conductor shape: Aluminum Or Copper
2. Conductor screen: Semi-conductive material
3. Insulation: XLPE
4. Insulation screen: Semi-conductive material
5. Armoured: Steel wire armour or steel tape armour or alumium wire armour
6 Sheath: PVC or MDPE, HDPE, LDPE
3. Operating characteristics
– Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.
– Max.admissible operating temperature of the conductor:90ºC.
– Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)
– The ambient temperature under installation should not below 0ºC.
– The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a multi-core cable should not less than 15 times of the cable diameter.
4. Table of the voltage, cores and cross-section
| 8.7/10kV,8.7/15kV Single Core Basic Parameters | ||||||||||||
| Nominal Cross Section (mm2 ) |
Thickness of Insulation mm | Thickness of Copper Tape mm | YJV,YJLV | Approx. weight of cable(kg/km) | YJV62,YJLV62 | Approx. weight of cable(kg/km) | ||||||
| Thickness of Sheath mm | Overall Diameter of Cable mm | YJV | YJLV | Thickness of PVC Insulation mm |
Thickness of Non-magnetic Steel tape mm | Thickness of Sheath mm | Overall Diameter of Cable mm | YJV62 | YJLV62 | |||
| 25 | 4.5 | 0.12 | 1.8 | 22.86 | 723 | 574 | 1.2 | 0.2 | 1.8 | 26.06 | 1020 | 871 |
| 35 | 4.5 | 0.12 | 1.8 | 23.86 | 839 | 632 | 1.2 | 0.2 | 1.8 | 27.06 | 1149 | 942 |
| 50 | 4.5 | 0.12 | 1.8 | 24.56 | 967 | 688 | 1.2 | 0.2 | 1.9 | 27.96 | 1299 | 1019 |
| 70 | 4.5 | 0.12 | 1.8 | 26.06 | 1196 | 792 | 1.2 | 0.2 | 1.9 | 29.46 | 1547 | 1143 |
| 95 | 4.5 | 0.12 | 1.8 | 27.76 | 1478 | 917 | 1.2 | 0.2 | 2 | 31.36 | 1866 | 1305 |
| 120 | 4.5 | 0.12 | 1.9 | 29.26 | 1745 | 1038 | 1.2 | 0.2 | 2 | 32.66 | 2138 | 1431 |
| 150 | 4.5 | 0.12 | 1.9 | 30.56 | 2027 | 1154 | 1.2 | 0.2 | 2.1 | 34.16 | 2452 | 1580 |
| 185 | 4.5 | 0.12 | 2 | 32.46 | 2414 | 1323 | 1.2 | 0.5 | 2.2 | 37.26 | 3208 | 2117 |
| 240 | 4.5 | 0.12 | 2.1 | 34.86 | 3018 | 1564 | 1.2 | 0.5 | 2.2 | 39.46 | 3848 | 2395 |
| 300 | 4.5 | 0.12 | 2.1 | 36.76 | 3590 | 1790 | 1.3 | 0.5 | 2.3 | 41.76 | 4507 | 2707 |
| 400 | 4.5 | 0.12 | 2.3 | 39.76 | 4438 | 2136 | 1.3 | 0.5 | 2.4 | 44.56 | 5402 | 3101 |
| 500 | 4.5 | 0.12 | 2.3 | 43.56 | 5608 | 2608 | 1.4 | 0.5 | 2.5 | 48.76 | 6712 | 3712 |
| 630 | 4.5 | 0.12 | 2.5 | 47.06 | 7020 | 3147 | 1.4 | 0.5 | 2.6 | 52.06 | 8182 | 4308 |
| 8.7/10kV,8.7/15kV 3 cores Basic Parameters | ||||||||||||
| Nominal Cross Section (mm2 ) |
Thickness of Insulation mm | Thickness of Copper Tape mm | YJV,YJLV | Approx. weight of cable(kg/km) | YJV22,YJLV22 | Approx. weight of cable(kg/km) | ||||||
| Thickness of Sheath mm | Overall Diameter of Cable mm | YJV | YJLV | Thickness of PVC Insulation mm | Thickness of Galvanized Steel tape mm | Thickness of Sheath mm | Overall Diameter of Cable mm | YJV22 | YJLV22 | |||
| 25 | 4.5 | 0.1 | 2.4 | 45.6 | 2365 | 1916 | 1.4 | 0.5 | 2.5 | 50.6 | 3495 | 3046 |
| 35 | 4.5 | 0.1 | 2.5 | 47.9 | 2733 | 2111 | 1.4 | 0.5 | 2.6 | 52.9 | 3918 | 3295 |
| 50 | 4.5 | 0.1 | 2.6 | 49.6 | 3210 | 2367 | 1.5 | 0.5 | 2.7 | 54.8 | 4463 | 3620 |
| 70 | 4.5 | 0.1 | 2.7 | 53.1 | 3936 | 2719 | 1.5 | 0.5 | 2.8 | 58.3 | 5272 | 4055 |
| 95 | 4.5 | 0.1 | 2.8 | 57.0 | 4854 | 3165 | 1.6 | 0.5 | 3 | 62.6 | 6346 | 4657 |
| 120 | 4.5 | 0.1 | 2.9 | 60.0 | 5677 | 3547 | 1.7 | 0.5 | 3.1 | 65.8 | 7278 | 5148 |
| 150 | 4.5 | 0.1 | 3 | 63.0 | 6613 | 3986 | 1.7 | 0.5 | 3.2 | 68.8 | 8291 | 5664 |
| 185 | 4.5 | 0.1 | 3.1 | 66.8 | 7785 | 4498 | 1.8 | 0.5 | 3.3 | 72.8 | 9600 | 6313 |
| 240 | 4.5 | 0.1 | 3.3 | 72.0 | 9749 | 5371 | 1.9 | 0.5 | 3.5 | 78.2 | 11737 | 7360 |
| 300 | 4.5 | 0.1 | 3.5 | 76.5 | 11580 | 6160 | 2 | 0.8 | 3.7 | 84.1 | 14533 | 9113 |
| 400 | 4.5 | 0.1 | 3.7 | 82.5 | 14229 | 7297 | 2.1 | 0.8 | 3.9 | 90.3 | 17451 | 10519 |
| 500 | 4.5 | 0.1 | 3.9 | 91.1 | 18058 | 9020 | 2.2 | 0.8 | 4.1 | 99.1 | 21656 | 12618 |
| 630 | 4.5 | 0.1 | 4.1 | 98.2 | 22403 | 10737 | 2.4 | 0.8 | 4.4 | 106.8 | 26431 | 14765 |
5. Type and Name
| Type | Designation | Applications | |
| YJV | Copper conductor,XLPE insulated,PVC sheathed power cable | For laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
| YJLV | Aluminum conductor,XLPE insulated,PVC sheathed power cable | ||
| YJY | Copper conductor, XLPE insulated,PE sheathed power cable | ||
| YJLY | Aluminum conductor, XLPE insulated,PE sheathed power cable | ||
| YJV22 | Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | For laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct. | |
| YJLV22 | Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cable | ||
| YJV23 | Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
| YJLV23 | Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cable | ||
| YJV32 | Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. | |
| YJLV32 | Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cable | ||
| YJV33 | Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cable | ||
| YJLV33 | Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable | ||
6. Our Factory
7. Our Honor
8. Contact Details
DAN ZHAO | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
Tel: 0086 532 85611663
Phone: 0086 17863817629
Website: taifengcable.en.
We are China 10kv Copper Conductor Steel Tape Armored Electric XLPE Insulation Open Air, Conduit, Duct PVC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electric Wire Products
High Voltage XLPE/PVC Insulated Electric Wire Power Cable IEC GB BS Standards
CABO BWF PVC FLEXIBLE 1.5mm2 750 V CABLE ABNT NBR NM 247-3
1/2/3/4/5 Core PVC XLPE Insulated Armoured Wet and Dry Locations Sta/Swa Electric Wire Power Cable
XLPE Insulated PVC Sheathed Underground Sta/Swa Electric Wire Cable
Popular Electrical Cable Products
XLPE Insulated Aluminum Tape PVC Power Cable
Electrical Four Cores Medium Voltage Cables Steel Tape Armoured Power Cables
Low Smoke Zero Halogen Flame Retardant Cable
Popular Power Cable Products
Electrical Cable Power Cable Copper Conductor ISO9001 Ce Certificated
30mm2 XLPE 11kv Aluminium PVC 240mm Power Cable
Low Voltage XLPE Insulated PVC Sheathed Sta Aluminum Electric Wire Cable
0.6/1kv XLPE/PVC Insulated and PVC/PE Sheathed Copper/Aluminium Electric Cable, Power Cable.
150mm2 240mm2 300mm2 Low Voltage Aluminum XLPE-PVC 0.6/1kv Power Cable
Popular taifengcable Products
Flexible Mineral Insulated Copper Conductor Fire Resistant Electric Wire Power Cable
XLPE Insulated Steel Tape Armoured Copper/Aluminum Conductor Electric Power Cable
450/750V H07V-K H05V-K PVC Insulated Flexible Moisture Resistant Copper Electrical Wire
XLPE Insulated PVC Sheathed Braid Shield Electric Flexible Use Wire Control Cable
Multi-Conductor Unshielded Steel/Copper Tape Armoured Fixed Installations Control Cable (KVV22)
Bare AAC Conductor/Overhead Aluminum Stranded Wire Electrical Cable
Tags: Electric Wire, Electrical Cable, Power Cable, taifengcable