Factory ACSR AAC AAAC Overhead Bare Conductor
Factory ACSR AAC AAAC Overhead Bare Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
Tel: 0086 532 85611663 Phone: 0086 15192706553
__________________________________________________________________________________________
Product Description
ACAR Aluminum Conductor Alloy Reinforced Aerial Bundle Cable
1. Specification
| JL All Aluminum Conductor Basic parameter | ||
| Specification | Outer Diameter of Cable | Approximate weight |
| 10 | 4.05 | 27.95 |
| 16 | 5.13 | 45.00 |
| 25 | 6.39 | 69.59 |
| 35 | 7.50 | 96.14 |
| 40 | 8.10 | 112.08 |
| 50 | 9.00 | 138.35 |
| 63 | 10.20 | 176.64 |
| 70 | 10.80 | 199.28 |
| 95 | 12.50 | 265.80 |
| 100 | 13.0 | 279.49 |
| 120 | 14.3 | 338.18 |
| 125 | 14.5 | 349.36 |
| 150 | 15.8 | 413.65 |
| 160 | 16.4 | 447.18 |
| 185 | 17.5 | 511.47 |
| 200 | 18.3 | 558.98 |
| 210 | 18.8 | 586.93 |
| 240 | 20.0 | 667.98 |
| 250 | 20.5 | 698.73 |
| 300 | 22.4 | 832.88 |
| 315 | 23.0 | 880.39 |
| 400 | 26.0 | 1117.96 |
| 450 | 27.6 | 1260.50 |
| 500 | 29.1 | 1405.84 |
| 560 | 30.7 | 1565.15 |
| 630 | 32.7 | 1763.58 |
| 710 | 34.7 | 1984.38 |
| 800 | 36.8 | 2238.72 |
| JL/G1A JL/G2A JL/G3A JL1/G1A JL1/G2A JL1/G3A JL2/G1A JL2/G2A JL2/G3A &JL3/G1A JL3/G2A JL3/G3A Aluminum Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.68 | 240/30 | 21.6 | 932.18 |
| 16/3 | 5.55 | 66.23 | 240/40 | 21.7 | 975.04 |
| 25/4 | 6.90 | 102.35 | 240/55 | 22.4 | 1117.98 |
| 35/6 | 8.16 | 143.40 | 250/25 | 21.5 | 892.12 |
| 40/6 | 8.73 | 164.01 | 250/40 | 22.2 | 1020.00 |
| 50/8 | 9.60 | 198.46 | 300/15 | 23.0 | 950.86 |
| 50/30 | 11.6 | 375.35 | 300/20 | 23.1 | 995.25 |
| 65/10 | 11.0 | 259.24 | 300/25 | 23.8 | 1069.16 |
| 70/10 | 11.4 | 279.25 | 300/40 | 23.9 | 1145.53 |
| 70/40 | 13.6 | 516.07 | 300/50 | 24.3 | 1223.68 |
| 95/15 | 13.6 | 384.61 | 300/70 | 25.2 | 1415.26 |
| 95/20 | 13.9 | 414.19 | 315/22 | 23.9 | 1055.27 |
| 95/55 | 16.0 | 714.12 | 400/20 | 26.9 | 1299.71 |
| 100/17 | 13.8 | 411.31 | 400/25 | 26.6 | 1309.52 |
| 120/7 | 14.5 | 384.69 | 400/35 | 26.8 | 1364.35 |
| 120/20 | 15.1 | 472.61 | 400/50 | 27.6 | 1526.85 |
| 120/25 | 15.7 | 532.00 | 400/65 | 28.0 | 1629.04 |
| 120/70 | 18.0 | 903.79 | 400/95 | 29.1 | 1876.79 |
| 125/7 | 14.9 | 404.07 | 450/30 | 28.6 | 1503.20 |
| 125/20 | 15.6 | 588.54 | 450/60 | 29.3 | 1721.49 |
| 150/8 | 16.0 | 468.73 | 500/35 | 30.1 | 1670.57 |
| 150/20 | 16.7 | 556.46 | 500/45 | 30.0 | 1706.92 |
| 150/25 | 17.1 | 607.47 | 500/65 | 30.9 | 1905.37 |
| 150/35 | 17.5 | 682.39 | 560/40 | 31.8 | 1869.84 |
| 160/9 | 16.8 | 517.20 | 560/70 | 32.7 | 2122.01 |
| 185/10 | 18.0 | 591.98 | 630/45 | 33.8 | 2100.58 |
| 185/25 | 18.9 | 713.67 | 630/55 | 34.3 | 2233.15 |
| 185/30 | 18.9 | 739.53 | 630/80 | 34.7 | 2386.32 |
| 185/45 | 19.6 | 857.27 | 710/50 | 35.9 | 2369.95 |
| 200/11 | 18.8 | 646.60 | 710/90 | 36.8 | 2688.85 |
| 210/10 | 19.0 | 659.36 | 720/50 | 36.2 | 2421.77 |
| 210/25 | 20.0 | 798.05 | 800/55 | 38.4 | 2719.46 |
| 210/35 | 20.4 | 864.06 | 800/70 | 38.6 | 2821.09 |
| 210/50 | 20.9 | 969.34 | 800/100 | 39.1 | 3038.27 |
| All Aluminum Alloy Conductor Basic parameter | |||||
| JLHA1 JLHA2 | JLHA3 JLHA4 | ||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 16 | 5.13 | 45.11 | 25 | 6.39 | 69.77 |
| 20 | 5.49 | 51.56 | 35 | 7.50 | 96.39 |
| 25 | 6.39 | 69.77 | 40 | 8.10 | 112.37 |
| 30 | 6.87 | 80.70 | 50 | 9.00 | 138.71 |
| 35 | 7.56 | 97.79 | 70 | 10.8 | 199.79 |
| 45 | 8.67 | 128.62 | 95 | 12.5 | 266.48 |
| 50 | 9.06 | 140.39 | 100 | 13.0 | 280.21 |
| 70 | 10.7 | 196.43 | 120 | 14.3 | 339.06 |
| 75 | 10.9 | 202.87 | 125 | 14.5 | 350.27 |
| 95 | 12.5 | 266.48 | 150 | 15.8 | 414.72 |
| 120 | 13.9 | 322.25 | 185 | 17.5 | 512.79 |
| 145 | 15.5 | 400.71 | 200 | 18.3 | 560.43 |
| 150 | 15.9 | 420.32 | 210 | 18.8 | 588.45 |
| 185 | 17.6 | 515.59 | 240 | 20.0 | 669.71 |
| 210 | 18.8 | 588.45 | 250 | 20.5 | 700.54 |
| 230 | 19.7 | 644.49 | 275 | 21.6 | 773.39 |
| 240 | 20.1 | 672.51 | 280 | 21.7 | 781.80 |
| 300 | 22.5 | 837.84 | 300 | 22.4 | 835.04 |
| 360 | 24.7 | 1014.37 | 315 | 23.0 | 882.67 |
| 400 | 26.0 | 1120.86 | 335 | 23.8 | 941.52 |
| 465 | 27.9 | 1288.98 | 340 | 23.9 | 952.73 |
| 500 | 29.1 | 1401.07 | 400 | 26.0 | 1120.86 |
| 520 | 29.5 | 1451.51 | 425 | 26.8 | 1193.71 |
| 580 | 31.2 | 1611.23 | 450 | 27.6 | 1263.77 |
| 630 | 32.7 | 1768.15 | 500 | 29.1 | 1409.48 |
| 650 | 33.0 | 1807.38 | 530 | 30.0 | 1487.94 |
| 720 | 35.0 | 2031.55 | 560 | 30.7 | 1569.20 |
| 800 | 36.8 | 2244.51 | 630 | 32.7 | 1768.15 |
| 675 | 33.8 | 1888.64 | |||
| 710 | 34.7 | 1989.52 | |||
| 800 | 36.8 | 2244.51 | |||
| JL(JL1,JL2,JL3)/LHA1 Aluminum Conductor Alloy Reinforced Basic parameter |
||
| Specification | Outer Diameter of Cable | Approximate weight |
| 25/20 | 8.34 | 118.92 |
| 40/30 | 10.5 | 187.47 |
| 60/45 | 13.2 | 297.71 |
| 80/50 | 14.9 | 368.16 |
| 105/60 | 16.8 | 470.27 |
| 130/140 | 21.4 | 758.42 |
| 135/80 | 18.9 | 593.36 |
| 135/140 | 21.6 | 772.42 |
| 135/145 | 21.7 | 780.81 |
| 165/170 | 23.8 | 940.34 |
| 165/175 | 23.9 | 951.53 |
| 170/95 | 21.1 | 739.68 |
| 210/220 | 26.8 | 1192.21 |
| 210/230 | 27.6 | 1262.18 |
| 235/250 | 28.7 | 1368.52 |
| 260/275 | 30.2 | 1516.85 |
| 265/60 | 23.4 | 906.83 |
| 270/420 | 34.2 | 1937.11 |
| 307/470 | 36.3 | 2177.85 |
| 335/80 | 26.4 | 1155.14 |
| 345/530 | 38.5 | 2454.98 |
| 365/165 | 30.0 | 1485.29 |
| 375/85 | 27.9 | 1293.28 |
| 415/95 | 29.5 | 1441.20 |
| 455/205 | 33.5 | 1854.52 |
| 465/110 | 31.2 | 1616.24 |
| 465/210 | 33.8 | 1885.28 |
| 505/65 | 31.1 | 1594.69 |
| 515/230 | 35.6 | 2092.27 |
| 535/240 | 36.2 | 2159.39 |
| 570/390 | 40.3 | 2677.54 |
| 580/260 | 37.7 | 2352.41 |
| 630/430 | 42.5 | 2979.70 |
| 650/295 | 40.0 | 2640.52 |
| 665/300 | 40.5 | 2710.44 |
| 705/485 | 45.0 | 3343.43 |
| 745/335 | 42.8 | 3029.31 |
| 790/540 | 47.5 | 3732.32 |
| 800/550 | 47.9 | 3785.48 |
| JLHA3/G1A (G2A ,G3A)&JLHA4/G1A (G2A ,G3A) Aluminum Alloy Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.75 | 240/40 | 21.7 | 976.77 |
| 16/3 | 5.55 | 66.35 | 240/55 | 22.4 | 1119.73 |
| 35/6 | 8.16 | 143.66 | 300/15 | 23.0 | 953.01 |
| 50/8 | 9.60 | 198.81 | 300/20 | 23.4 | 1014.02 |
| 50/30 | 11.6 | 375.72 | 300/25 | 23.8 | 1071.37 |
| 70/10 | 11.4 | 279.74 | 300/40 | 23.9 | 1147.70 |
| 70/40 | 13.6 | 516.58 | 300/50 | 24.3 | 1225.85 |
| 95/15 | 13.6 | 385.29 | 300/70 | 25.2 | 1417.47 |
| 95/20 | 13.9 | 414.88 | 400/20 | 26.9 | 1302.65 |
| 95/55 | 16.0 | 714.82 | 400/25 | 26.6 | 1312.36 |
| 120/7 | 14.5 | 385.63 | 400/35 | 26.8 | 1367.18 |
| 120/20 | 15.1 | 473.45 | 400/50 | 27.6 | 1529.74 |
| 120/25 | 15.7 | 532.89 | 400/65 | 28.0 | 1631.93 |
| 120/70 | 18.0 | 904.67 | 400/95 | 29.1 | 1879.75 |
| 150/8 | 16.0 | 469.77 | 460/60 | 29.8 | 1778.19 |
| 150/20 | 16.7 | 557.51 | 500/35 | 30.1 | 1674.19 |
| 150/25 | 17.1 | 608.54 | 500/45 | 30.0 | 1710.46 |
| 150/35 | 17.5 | 683.45 | 500/65 | 31.0 | 1920.55 |
| 185/10 | 18.0 | 593.31 | 630/45 | 33.8 | 2105.13 |
| 185/25 | 18.9 | 715.03 | 630/55 | 34.3 | 2237.78 |
| 185/30 | 18.9 | 740.84 | 630/80 | 34.5 | 2365.74 |
| 185/45 | 19.6 | 858.61 | 710/50 | 35.9 | 2375.08 |
| 210/10 | 19.0 | 660.83 | 710/90 | 36.8 | 2693.98 |
| 210/25 | 20.0 | 799.56 | 720/50 | 36.2 | 2427.02 |
| 210/35 | 20.4 | 865.59 | 800/55 | 38.2 | 2688.92 |
| 210/50 | 20.9 | 970.85 | 800/70 | 38.6 | 2826.94 |
| 240/30 | 21.6 | 933.95 | 800/100 | 39.1 | 3041.69 |
2. Our Factory
3. Our Honor
4. Contact Details
Jessica Wang | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
Tel: 0086 532 85611663
Phone: 0086 15192706553
Website: taifengcable.en.
We are China Factory ACSR AAC AAAC Overhead Bare Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundle Cable Products
ABC Cable Low Voltage Aerial Bundle Cable with Steel Messenger
Astmb-232 Triplex Service Drop-Aluminum Conductor Aerial Bundle Cable Hippa Shrimp
PVC XLPE Insulated Duplex, Triplex, Quadruplex Cable Overhead ABC Cable
ABC Cable, Insulated Aerial Cable, Aerial Bundled Cable
2018 Jinshui Brand Aerial Bundle Cable ABC Cable
Astmb-232 Duplex Service Drop Aluminum Aerial Bundle Cable Collie Shepherd Whippet
Popular taifengcable Products
PV-1f 4AWG Sunlight Resistant Electric Solar Panels PV Solar Power Cable
Copper Conductor PVC Insulated 1.5 2.5 6mm2 Industrial Applications House Building Wire
High Performance 450/750V Flexible Copper Conductor with PVC Jacket/Sheath Control Cable
11kv Single Core XLPE Insulated Copper Wire Shield Aluminum Power Cable
Low Smoke Halogen Free XLPE Insulated PVC Sheathed Power Cable
Low Voltage PVC/XLPE Insulated Aluminum/Copper Conductor 4*120mm2 Aerial Bundle Conductor Cable
Popular Triplex Cable Products
0.6/1 Kv ABC– Aerial Bundled Cables– NFC 33-209 (AL/XLPE) ABC Cable for Electric Power Transmission
Triplex Sevice Drop (ABC) Cable
XLPE Insulated Service Cable (SDW)
Stranded Aluminium Conductor 11kv ABC Cable
Medium Voltage XLPE Insulated Parallel and Twisted Aerial Bundled Cable, ABC Cable, Electrical Cable
Jlha1 Jlha2 Jlha3 Jlha4 AAAC All Aluminum Alloy Conductor Aerial Bundle Cable
Popular Twisted Aluminum Cable Products
NFC Cable Aerial Bundled Cable with Insulation PE/XLPE
Aluminum Twisted Cable 1+1 with PE Insulation Low Volatge
Aluminum Product Overhead Power Cable
0.6/1kv Twisted Aluminum Conductor ABC Cable
Duplex Triplex Quadruplex Service Drop Aluminum Conductor ABC Cable
0.6/1kv Twisted Aluminum Bouded Cable
Tags: Aerial Bundle Cable, taifengcable, Triplex Cable, Twisted Aluminum Cable