Price 240mm2 AAC Aluminum Conductor Power Cable Bare Conductor AAC Saudi
Price 240mm2 AAC Aluminum Conductor Power Cable Bare Conductor AAC Saudi image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
| IEC 61089 | ||||||
| Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
| mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| 10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
| 16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
| 25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
| 40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
| 63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
| 100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
| 125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
| 160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
| 200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
| 250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
| 315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
| 400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
| 450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
| 500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
| 560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
| 900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
| 1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
| 1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
| 1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
| 1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
| ASTM B231/B 231M | |||||||
| Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
| AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
| Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
| Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
| Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
| Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
| Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
| Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
| Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
| Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
| Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
| Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
| Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
| Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
| Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
| Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
| Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
| Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
| Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
| Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
| Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
| Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
| Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
| Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
| Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
| Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
| Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
| Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
| Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
| Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
| Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
| BS 215 Part 1 | |||||||
| Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
| mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
| Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
| Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
| Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
| Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
| Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
| Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
| Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
| Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
| Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
| Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
| Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
| Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
| Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
| Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
| Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
| Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
| Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
| Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
| Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
| Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
| Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
| Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
| Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
| Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
| Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
| Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
| Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
| Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
| Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
| Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
| BS EN 50182 | ||||||
| Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
| mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
| Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
| Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
| Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
| Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
| Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
| Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
| Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
| Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
| Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
| Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
| Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
| Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
| Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
| Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Price 240mm2 AAC Aluminum Conductor Power Cable Bare Conductor AAC Saudi manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 240mm2 AAC Aluminum Conductor Power Cable Products
Popular AAC Aluminum Conductor Saudi Products
Popular Aluminum Conductor AAC Products
AAAC, ACSR, AAC Aluminum Stranded Conductor ACSR Conductor Sizes
Bare Steel Reinforced Overhead ACSR Conductor
Overhead Bare Aluminum Conductor AAC, AAAC, ACSR, Acar
Overhead Aluminum Conductor AAC ACSR Wire ACSR Conductor
Hard Drawn All Aluminum Conductor AAC
Popular kingyear Products
1000 Series Aluminum Coil with Protective Film for Wall Decoration
2 Core Electrical Wire 1.5mm Cable Electrical Cable Wire Flexible Fireproof Electric Wire
ACSR AAC AAAC Aluminium Alloy Conductor Overhead Bare Conductor Stranded Conductor
1050 1060 3003 Aluminum Disc/Circle/Waferfor Cookware, Kitchen, Lamp Use
450/750V Energy Wire PVC Insulated Electrical Wires
Tags: 240mm2 AAC Aluminum Conductor Power Cable, AAC Aluminum Conductor Saudi, Aluminum Conductor AAC, kingyear