Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor
Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
| IEC 61089 | ||||||
| Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
| mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| 10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
| 16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
| 25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
| 40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
| 63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
| 100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
| 125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
| 160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
| 200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
| 250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
| 315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
| 400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
| 450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
| 500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
| 560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
| 900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
| 1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
| 1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
| 1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
| 1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
| ASTM B231/B 231M | |||||||
| Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
| AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
| Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
| Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
| Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
| Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
| Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
| Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
| Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
| Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
| Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
| Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
| Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
| Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
| Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
| Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
| Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
| Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
| Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
| Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
| Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
| Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
| Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
| Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
| Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
| Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
| Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
| Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
| Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
| Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
| Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
| BS 215 Part 1 | |||||||
| Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
| mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
| Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
| Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
| Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
| Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
| Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
| Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
| Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
| Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
| Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
| Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
| Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
| Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
| Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
| Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
| Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
| Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
| Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
| Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
| Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
| Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
| Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
| Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
| Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
| Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
| Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
| Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
| Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
| Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
| Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
| Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
| BS EN 50182 | ||||||
| Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
| mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
| Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
| Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
| Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
| Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
| Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
| Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
| Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
| Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
| Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
| Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
| Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
| Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
| Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
| Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Gnat Conductor Products
AAC Gnat Conductor/AAC AAAC ACSR Conductor Price
795 AAC Gnat Conductor Coreopsis Conductor 55 Sq mm AAAC Conductor Price
AAC Gnat Conductor Bare Overhead Aluminum Conductor
Popular AAC Transmission Line Products
Popular kingyear Products
1272kcmil/Mcm ACSR Bittern Conductor (Al 45/4.27 + St 7/2.85mm)
1kv 11kv 35kv 1X400mm 1X400mm2 XLPE/Cws/Cts/PVC/Awa/PVC Power Cable
Bright Finish 5754 Aluminum Plate/Sheet/Coil/Strip Factory Direct Sale
35kv Single Core High Voltage Copper Conductor XLPE Insulated Electric Urd Power Cable 500mcm
AAAC Conductor Aluminum Alloy Conductor ASTM B399
Popular Overhead Line Conductor Products
Acar Conductor 750 Kcmil 18/19
100mm2 (7/4.26mm) Stranded Aluminum Alloy Wire Overhead Conductor
Quadruplex Cable 3+1 Aluminum Conductor XLPE Insulated
Overhead Line Conductor Aerial Twisted Aluminum ABC Cable
IEC61089 AAC/AAAC/ACSR Conductor High Quality Overhead Conductors Price
Power Transmission Line ACSR Cable ASTM B323-81 ACSR Eagle ASTM B232 30/7
Tags: AAC Gnat Conductor, AAC Transmission Line, kingyear, Overhead Line Conductor