Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor
Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
Applications:
Concentric lay stranded Aluminium Conductor ( AAC) is made up of one or more strands of hard drawn 1350 aluminum alloy. These conductors are used in low, medium and high voltage overhead lines. AAC has seen extensive use in urban areas where spans are usually short but high conductivity us required. The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas. Because of its relatively poor strength to weight ratio, AAC had limited use in transmission lines and rural distribution because of long spans utilized.
The excellent corrosion resistance of aluminium has made AAC a conductor of choice in coastal areas.Although aluminium-to-copper connections can be made, it is better to use aluminium conductors for service connections, as various forms of covered cable are available for this purpose.
Advantage:
1. high Current Carrying Capacity
2. excellent resistance to corrosion
3. Ideal for use in coastal area
4. suitable for low & medium voltage lines in urban area
Standard
ASTM B231, BS215, IEC 61089, DIN 48201, BS EN 50182
| IEC 61089 | ||||||
| Code Name | Nominal | No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
| mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| 10 | 10 | 7/1.35 | 4.05 | 27.4 | 2 | 2.8633 |
| 16 | 16 | 7/1.71 | 5.13 | 43.8 | 3 | 1.7896 |
| 25 | 25 | 7/2.13 | 6.39 | 68.4 | 4.5 | 1.1453 |
| 40 | 40 | 7/2.70 | 8.1 | 109.4 | 6.8 | 0.7158 |
| 63 | 63 | 7/3.39 | 10.17 | 172.3 | 10.4 | 0.4545 |
| 100 | 100 | 19/2.59 | 12.95 | 274.8 | 17 | 0.2877 |
| 125 | 125 | 19/2.89 | 14.45 | 343.6 | 21.3 | 0.2302 |
| 160 | 160 | 19/3.27 | 16.35 | 439.8 | 26.4 | 0.1798 |
| 200 | 200 | 19/3.66 | 18.3 | 549.7 | 32 | 0.1439 |
| 250 | 250 | 19/4.09 | 20.45 | 687.1 | 40 | 0.1151 |
| 315 | 315 | 37/3.29 | 23.03 | 867.9 | 52 | 0.0916 |
| 400 | 400 | 37/3.71 | 25.97 | 1102 | 64 | 0.0721 |
| 450 | 450 | 37/3.94 | 27.58 | 1239.8 | 72 | 0.0641 |
| 500 | 500 | 37/4.15 | 29.05 | 1377.6 | 80 | 0.0577 |
| 560 | 560 | 37/4.39 | 30.73 | 1542.9 | 89.6 | 0.0515 |
| 630 | 630 | 61/3.63 | 32.67 | 1738.3 | 100.8 | 0.0458 |
| 710 | 710 | 61/3.85 | 34.65 | 1959.1 | 113.6 | 0.0407 |
| 800 | 800 | 61/4.09 | 36.81 | 2207.4 | 128 | 0.0361 |
| 900 | 900 | 61/4.33 | 38.97 | 2483.3 | 144 | 0.0321 |
| 1000 | 1000 | 61/4.57 | 41.13 | 2759.2 | 160 | 0.0289 |
| 1120 | 1120 | 91/3.96 | 43.56 | 3093.5 | 179.2 | 0.0258 |
| 1250 | 1250 | 91/4.18 | 45.98 | 3452.6 | 200 | 0.0231 |
| 1400 | 1400 | 91/4.43 | 48.73 | 3866.9 | 224 | 0.0207 |
| 1500 | 1500 | 91/4.58 | 50.38 | 4143.1 | 240 | 0.0193 |
| ASTM B231/B 231M | |||||||
| Code Name | Nominal Area |
No./Nominal diameter of wires |
Approximate Overall Diameter |
Approximate Weight |
Nominal Breaking Load |
Nominal DC Resistance at 20°C |
|
| AWG or MCM | mm2 | No./mm | mm | kg/km | KN | ohm/km | |
| Peachbell | 6 | 13.3 | 7/1.56 | 4.68 | 36.6 | 2.5 | 2.1477 |
| Rose | 4 | 21.1 | 7/1.96 | 5.88 | 58.2 | 3.9 | 1.3606 |
| Iris | 2 | 33.6 | 7/2.47 | 7.41 | 92.6 | 6 | 0.8567 |
| Pansy | 1 | 42.4 | 7/2.78 | 8.34 | 116.6 | 7.3 | 0.6763 |
| Poppy | 1/0.0 | 53.5 | 7/3.12 | 9.36 | 147.2 | 8.8 | 0.5369 |
| Aster | 2/0.0 | 67.4 | 7/3.50 | 10.5 | 185.7 | 11.1 | 0.4267 |
| Phlox | 3/0.0 | 85 | 7/3.93 | 11.79 | 233.9 | 13.5 | 0.3384 |
| Oxlip | 4/0.0 | 107.2 | 7/4.42 | 13.26 | 295.2 | 17 | 0.2675 |
| Valerian | 250 | 126.7 | 19/2.91 | 14.55 | 348.6 | 20.7 | 0.2274 |
| Sneezewort | 250 | 126.7 | 7/4.80 | 14.4 | 348.8 | 20.1 | 0.2269 |
| Laurel | 266.8 | 135.2 | 19/3.01 | 15.05 | 372.2 | 22.1 | 0.2125 |
| Daisy | 266.8 | 135.2 | 7/4.96 | 14.88 | 372.3 | 21.4 | 0.2125 |
| Peony | 300 | 152 | 19/3.19 | 15.95 | 418.3 | 24.3 | 0.1892 |
| Tulip | 336.4 | 170.5 | 19/3.38 | 16.9 | 469.5 | 27.3 | 0.1686 |
| Daffodil | 350 | 177.3 | 19/3.45 | 17.25 | 487.9 | 28.4 | 0.1618 |
| Canna | 397.5 | 201.4 | 19/3.67 | 18.35 | 554.9 | 31.6 | 0.143 |
| Goldentuft | 450 | 228 | 19/3.91 | 19.55 | 627.6 | 35 | 0.126 |
| Syringa | 477 | 241.7 | 37/2.88 | 20.16 | 664.8 | 38.6 | 0.1192 |
| Cosmos | 477 | 241.7 | 19/4.02 | 20.1 | 664.8 | 37 | 0.1192 |
| Hyacinth | 500 | 253.3 | 37/2.95 | 20.65 | 696.8 | 40.5 | 0.1136 |
| Zinnia | 500 | 253.3 | 19/4.12 | 20.6 | 697.1 | 38.9 | 0.1134 |
| Dahlia | 556.5 | 282 | 19/4.35 | 21.75 | 775.8 | 43.3 | 0.1018 |
| Mistletoe | 556.5 | 282 | 37/3.12 | 21.84 | 775.7 | 44.3 | 0.1016 |
| Meadowsweet | 600 | 304 | 37/3.23 | 22.61 | 836.3 | 47.5 | 0.0948 |
| Orchid | 636 | 322.3 | 37/3.33 | 23.31 | 886.9 | 50.4 | 0.0892 |
| Heuchera | 650 | 329.4 | 37/3.37 | 23.59 | 907.4 | 51.7 | 0.0871 |
| Flag | 700 | 354.7 | 61/2.72 | 24.48 | 975.8 | 57.1 | 0.0811 |
| Varbena | 700 | 354.7 | 37/3.49 | 24.43 | 975.7 | 55.4 | 0.0812 |
| Nasturtium | 715.5 | 362.6 | 61/2.75 | 24.75 | 998.5 | 58.4 | 0.0793 |
| Violet | 715.5 | 362.6 | 37/3.53 | 24.71 | 998.5 | 56.7 | 0.0794 |
| Cattail | 750 | 380 | 61/2.82 | 25.38 | 1046 | 60.3 | 0.0754 |
| Petunia | 750 | 380 | 37/3.62 | 25.34 | 1046 | 58.6 | 0.0755 |
| Lilac | 795 | 402.8 | 61/2.90 | 26.1 | 1110 | 63.8 | 0.0713 |
| Arbutus | 795 | 402.8 | 37/3.72 | 26.04 | 1109 | 61.8 | 0.0715 |
| BS 215 Part 1 | |||||||
| Code name | Nominal | No./Nominal diameter of wires |
Sectional Area | Overall | Weight | Calculated Breaking Load | Max.D.C. Resistance at 20ºC |
| mm² | No./mm | mm² | mm | kg/km | daN | Ω/Km | |
| Midge | 22 | 7/2.06 | 23.33 | 6.18 | 64 | 399 | 1.227 |
| Aphis | 25 | 3/3.35 | 26.44 | 7.22 | 74 | 411 | 1.081 |
| Gnat | 25 | 7/2.21 | 26.85 | 6.63 | 73 | 459 | 1.066 |
| Weevil | 30 | 3/3.66 | 31.56 | 7.89 | 86 | 486 | 0.9082 |
| Mosquito | 35 | 7/2.59 | 36.88 | 7.77 | 101 | 603 | 0.7762 |
| Ladybird | 40 | 7/2.79 | 42.8 | 8.37 | 117 | 687 | 0.6689 |
| Ant | 50 | 7/3.10 | 52.83 | 9.3 | 145 | 828 | 0.5419 |
| Fly | 60 | 7/3.40 | 63.55 | 10.2 | 174 | 990 | 0.4505 |
| Bluebottle | 70 | 7/3.66 | 73.65 | 10.98 | 202 | 1134 | 0.3881 |
| Earwig | 75 | 7/3.78 | 78.55 | 11.34 | 215 | 1194 | 0.3644 |
| Grasshopper | 80 | 7/3.91 | 84.05 | 11.73 | 230 | 1278 | 0.3406 |
| Clegg | 90 | 7/4.17 | 95.6 | 12.51 | 262 | 1453 | 0.2994 |
| Wasp | 100 | 7/4.39 | 106 | 13.17 | 290 | 1600 | 0.2702 |
| Beetle | 100 | 19/2.67 | 106.4 | 13.35 | 293 | 1742 | 0.2704 |
| Bee | 125 | 7/4.90 | 132 | 14.7 | 361 | 1944 | 0.2169 |
| Cricket | 150 | 7/5.36 | 157.9 | 16.08 | 432 | 2385 | 0.1818 |
| Hornet | 150 | 19/3.25 | 157.6 | 16.25 | 434 | 2570 | 0.1825 |
| Caterpillar | 175 | 19/3.53 | 185.9 | 17.65 | 511 | 2863 | 0.1547 |
| Chafer | 200 | 19/3.78 | 213.2 | 18.9 | 587 | 3240 | 0.1349 |
| Spider | 225 | 19/3.99 | 237.6 | 19.95 | 654 | 3601 | 0.1211 |
| Cockroach | 250 | 19/4.22 | 265.7 | 21.1 | 731 | 4040 | 0.1083 |
| Butterfly | 300 | 19/4.65 | 322.7 | 23.25 | 888 | 4875 | 0.08916 |
| Moth | 350 | 19/5.00 | 373.1 | 25 | 1027 | 5637 | 0.07711 |
| Drone | 350 | 37/3.58 | 372.4 | 25.06 | 1027 | 5745 | 0.07741 |
| Locust | 400 | 19/5.36 | 428.7 | 26.8 | 1180 | 6473 | 0.0671 |
| Centipede | 400 | 37/3.78 | 415.2 | 26.46 | 1145 | 6310 | 0.06944 |
| Maybug | 450 | 37/4.09 | 486.1 | 28.63 | 1340 | 7401 | 0.05931 |
| Scorpion | 500 | 37/4.27 | 529.8 | 29.89 | 1461 | 7998 | 0.05441 |
| Cicada | 600 | 37/4.65 | 628.3 | 32.55 | 1732 | 9495 | 0.04588 |
| Tarantula | 750 | 37/5.23 | 794.9 | 36.61 | 2192 | 12010 | 0.03627 |
| BS EN 50182 | ||||||
| Code Name |
Nominal Area |
No. / Dia. of Wire |
Approx. Overall Diameter | Approx. Weight |
Calculated Breaking Load | Max.DC Resistance at 20° C |
| mm2 | No. / mm | mm | kg/km | kN | Ohm/km | |
| Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.6 | 1.748 |
| Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7 | 1.3828 |
| Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.9 | 1.0926 |
| Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.5 | 0.9273 |
| Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.4 | 0.7797 |
| Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.1 | 0.6875 |
| Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.7 | 0.5494 |
| Pine | 71.6 | 7/3.61 | 10.83 | 195.6 | 21.1 | 0.4591 |
| Holly | 84.1 | 7/3.91 | 11.73 | 229.5 | 24.8 | 0.3913 |
| Willow | 89.7 | 7/4.04 | 12.12 | 245 | 26.5 | 0.3665 |
| Oak | 118.9 | 7/4.65 | 13.95 | 324.5 | 35.1 | 0.2767 |
| Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.5 | 0.2192 |
| Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.3 | 0.183 |
| Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.2 | 0.1568 |
| Poplar | 239.4 | 37/2.87 | 20.09 | 659.4 | 70.6 | 0.1387 |
| Sycamore | 303.2 | 37/3.23 | 22.61 | 835.2 | 89.4 | 0.1095 |
| Upas | 362.1 | 37/3.53 | 24.71 | 997.5 | 106.8 | 0.0917 |
| Yew | 479 | 37/4.06 | 28.42 | 1319.6 | 141.3 | 0.0693 |
| Totara | 498.1 | 37/4.14 | 28.98 | 1372.1 | 146.9 | 0.0666 |
| Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.1 | 0.0567 |
| Sorbus | 659.4 | 61/3.71 | 33.39 | 1822.5 | 194.5 | 0.0505 |
| Araucaria | 821.1 | 61/4.14 | 37.26 | 2269.4 | 242.2 | 0.0406 |
| Redwood | 996.2 | 61/4.56 | 41.04 | 2753.2 | 293.9 | 0.0334 |
As a leading manufacture in China,Our customers come from around the world,Welcome to visit us at any time!
Just leave your message if you are interested in our products,We will contact you very soon!
We are China Overhead Line Conductor AAC Transmission Line AAC Gnat Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Gnat Conductor Products
795 AAC Gnat Conductor Coreopsis Conductor 55 Sq mm AAAC Conductor Price
AAC Gnat Conductor Bare Overhead Aluminum Conductor
AAC Gnat Conductor/AAC AAAC ACSR Conductor Price
Popular AAC Transmission Line Products
Popular kingyear Products
1.5mm2 2.5mm2 Multi Core Power Cable 0.6/1kv Copper/Aluminum Core Swa/XLPE Insulated Power Cable
ASTM B232 Overhead Bare Aluminium ACSR Conductor 666.6mcm Flamingo Gannet
11kv Overhead Transmission Line ACSR Conductor Power Cable
3 Core Aluminum Copper Conductor Medium Voltage Armoured XLPE/PVC Insulated Power Cable
Rolled A5056 Aluminum Plate/Sheet/Coil/Strip Fresh Stock
Power Cable VDE Standard Nyy, Nayy, Na2xy, N2xy, N2xry Cable
Popular Overhead Line Conductor Products
100mm2 (7/4.26mm) Stranded Aluminum Alloy Wire Overhead Conductor
Acar Conductor 750 Kcmil 18/19
Tags: AAC Gnat Conductor, AAC Transmission Line, kingyear, Overhead Line Conductor