KINGYEAR Cable is one of the leading cable products production enterprise in China,our mainly products are electric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable as below.
The technical data of
PVC/XLPE/HDPE Insulated ABC cable size type overhead sizes as below for reference:| Duplex service drop | |||||||||
| Code Name | Phase conductor | Bare Neutral Message | Nominal Weight ( kg/km ) | Allowable Ampacity | |||||
| Size & No.of wires | Insulation Thick(mm) | Nominal Diameter (mm) | Size & No.of wires | Rated Strength (kg) | XLPE | Aluminum | ( A ) | ||
| Bare | OD | ||||||||
| AAC | |||||||||
| Pekingese | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 255 | 20.8 | 72.9 | 78 |
| Collie | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 255 | 23.8 | 72.9 | 78 |
| Cocker | 6-7 | 1.52 | 4.6 | 7.7 | 6-7 | 255 | 32.7 | 72.9 | 78 |
| Dachshund | 4-Solid | 1.14 | 5.2 | 7.5 | 6-7 | 400 | 26.8 | 114.6 | 103 |
| Spaniel | 4-7 | 1.14 | 5.9 | 8.2 | 6-7 | 400 | 29.8 | 116.1 | 103 |
| Cairn | 4-7 | 1.52 | 5.9 | 8.9 | 6-7 | 400 | 40.2 | 116.1 | 103 |
| Doberman | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 612 | 38.7 | 184.5 | 136 |
| Airedale | 1-19 | 1.52 | 8.4 | 11.5 | 1-7 | – | 56.5 | 233.6 | 158 |
| Basset | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| Malemure | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 903 | 64 | 294.7 | 182 |
| AAAC | |||||||||
| Chihuahua | 6-Solid | 1.14 | 4.1 | 6.4 | 6-7 | 499 | 20.8 | 72.9 | 78 |
| VIzsla | 6-7 | 1.14 | 4.6 | 6.9 | 6-7 | 499 | 23.8 | 72.9 | 78 |
| Harrier | 4-Solid | 1.14 | 5.2 | 7.5 | 4-7 | 798 | 26.8 | 116.1 | 103 |
| Whippet | 4-7 | 1.14 | 5.9 | 8.2 | 4-7 | 798 | 29.8 | 116.1 | 103 |
| Schnauzer | 2-7 | 1.14 | 7.4 | 9.7 | 2-7 | 1270 | 38.7 | 184.5 | 136 |
| Afghan | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| Hocler | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-7 | 2023 | 64 | 296.1 | 182 |
| ACSR | |||||||||
| Setter | 6-Solid | 1.14 | 4.1 | 6.4 | 6/6/01 | 540 | 20.8 | 72.9 | 78 |
| Shepherd | 6-7 | 1.14 | 4.6 | 6.9 | 6/6/01 | 540 | 23.8 | 72.9 | 78 |
| Retriever | 6-7 | 1.52 | 4.6 | 7.7 | 6/6/01 | 540 | 32.7 | 72.9 | 78 |
| Eskimo | 4-Solid | 1.14 | 5.2 | 7.5 | 4/6/01 | 844 | 26.8 | 114.6 | 103 |
| Terrier | 4-7 | 1.14 | 5.9 | 8.2 | 4/6/01 | 844 | 29.8 | 116.1 | 103 |
| Yorkshirc | 4-7 | 1.52 | 5.9 | 8.9 | 4/6/01 | 844 | 40.2 | 116.1 | 103 |
| Chow | 2-7 | 1.14 | 7.4 | 9.7 | 2/6/01 | 1293 | 38.7 | 184.5 | 136 |
| Labrador | 1-19 | 1.52 | 8.4 | 11.5 | 1/6/01 | 1610 | 56.5 | 233.6 | 158 |
| Bloodhound | 1/0-7 | 1.52 | 9.3 | 12.4 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| Bull | 1/0-19 | 1.52 | 9.4 | 12.5 | 1/0-6/1 | 1987 | 64 | 294.7 | 182 |
| Service Drop | :To supply 120 volt aerial service for temporary service at construction sites,outdoor or street lighting.For service at 600 volts or lower at a conductor temperature of 75°C maximum. |
| Triplex Service Drop | To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volt or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene insulation 90°C maximum for crosslinked insulation. |
| Quadruplex Service Drop | Used to supply 3 phase power, usually from a polemounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulation 90°C maximum for crosslinked polyethylene(XLPE) insulated conductors |
Some ABC Aerial Bundled Cable Applications shown as below:
After more than 10 years of development, our customers have spread to more than 40 countries and regions around the world, of which more than 50% are old customers.our power cable,control cable,ABC overhead cable,bare conductor(AAC/AAAC/ACSR) are more favorited by them.We are proud of our good quality-KINGYEAR CABLE.
The packaging of PVC/XLPE/HDPE Insulated ABC cable size type overhead sizes as below,customized is accepted.
If Any interesting of the ectric wire,power cable, control cable,bare conductor(AAC/AAAC/ACSR),ABC overhead cable can email us freely:
price inquiry !!!
∨∨∨
We are China PVC/XLPE/HDPE Insulated ABC Cable Size Type Overhead Sizes manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Size Products
Various Sizes of ABC Cables for Sale
0.6/1kv XLPE Insulated ABC Cable Aluminum Overhead Cable Size
0.6/1kv AAC AAAC Conductor XLPE Insulated NFC Standard ABC Cable
ABC Cable Size 3X70+54.6+16sqmm Aerial Bundle Cable Overhead Cable
Popular ABC Cable Size Type Overhead Products
Popular ABC Cable Sizes Products
AAC/ACSR/AAAC Core Overhead Aerial Bundled Cable ABC Cable
High Quality ABC Cable -Aerial Bundle Cable
Overhead Messenger ABC Cable Aerial Bundled International Stranded Aluminium Conductor
3 X 70 50 Low Voltage Aerial Bundled Cable with Strand Aluminum Conductor
Aluminium Cable 3 Phase Electric Transmission Project Electrical ABC Cable
3+1+K Cores 0.6 / 1kv Aluminum Conductor XLPE Insulation Aerial Bundle Cable
Popular kingyear Products
Rvs Twisted Electric Cable 2 Cores Flexible Wire
Copper 3 Core2 Core PVC Medium Power Cable
OEM Copper Conductor XLPE Insulation Armoured Electrical Cable
AAAC Conductor IEC 61089 All Aluminum Alloy Conductor Stranded Bare Conductor for Overhead Lines
Armoured PVC Insulated Sheathed VV22 Power Cable Manufacturer
Underground Electrical Copper Core XLPE/PVC/PE Insulated High Quality Power Cable
Tags: ABC Cable Size, ABC Cable Size Type Overhead, ABC Cable Sizes, kingyear