24*1.0 24*1.5 24*2.5 Copper Control Cable PVC Sheathed Cable
24*1.0 24*1.5 24*2.5 Copper Control Cable PVC Sheathed Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application: Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.
Construction- Conductors:Annealed Copper Wire
– Insulation : PVC
– Core Identification : Coloring Method – below 4 cores
(2 cores – Black, White /3 cores – Black, White, Red )
Numbering Method (Above 5 cores)
– Sheath : PVC
Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS
2 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 2 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 98 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 10.0 | 24.5 | 0.0142 | 110 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 10.5 | 18.1 | 0.0135 | 115 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 11.0 | 12.1 | 0.0115 | 135 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 12.0 | 7.41 | 0.0093 | 180 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 14.5 | 4.61 | 0.0092 | 255 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 15.5 | 3.08 | 0.0078 | 320 | 500/D |
3 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
5 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
9 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
11 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 11 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 255 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 315 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 340 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 425 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 605 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 915 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1220 | 500/D |
12 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 12 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 265 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 320 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 345 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 440 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 630 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 950 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1270 | 500/D |
13 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 13 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 295 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 355 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 380 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 485 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 695 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1050 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1405 | 500/D |
14 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 14 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 300 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 360 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 390 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 495 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 715 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1085 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1455 | 500/D |
15 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 15 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 395 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 425 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 545 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 785 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1195 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1600 | 500/D |
16 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 16 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 400 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 435 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 555 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 805 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1230 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1650 | 500/D |
17 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 17 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 355 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 430 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 465 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 595 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 865 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1315 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1785 | 500/D |
18 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 18 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 360 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 435 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 475 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 605 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 885 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1350 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1835 | 500/D |
19 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 19 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 365 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 445 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 480 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 620 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 905 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1385 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1885 | 500/D |
20 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 20 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 390 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 475 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 515 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 665 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 975 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1490 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
21 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 21 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 400 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 490 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 530 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 685 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 1005 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1540 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
22 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 22 | 0.5 | 7/0.30 | 0.8 | 1.8 | 20.0 | 36.0 | 0.0162 | 430 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 520 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 565 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 730 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 265 | 7.41 | 0.0093 | 1070 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1655 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2245 | 500/D |
23 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 23 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.5 | 36.0 | 0.0162 | 440 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 540 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 585 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 755 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 26.5 | 7.41 | 0.0093 | 1105 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1710 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
24 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 24 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 460 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.0 | 24.5 | 0.0142 | 560 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 605 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 24.5 | 12.1 | 0.0115 | 785 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.0 | 7.41 | 0.0093 | 1150 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 34.5 | 4.61 | 0.0092 | 1795 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
25 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 25 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 490 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 595 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 645 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 835 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1225 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1915 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2595 | 500/D |
26 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
27 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
28 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 28 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 535 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 650 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 710 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 915 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1350 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2110 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2885 | 500/D |
29 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 29 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 660 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 715 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 930 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1370 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2145 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2940 | 500 |
We are China 24*1.0 24*1.5 24*2.5 Copper Control Cable PVC Sheathed Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 24*1.0 24*1.5 24*2.5 Copper Control Cable Products
Popular 24*1.0 Control Cable Products
Popular Control Cable Products
Copper Conductor XLPE/PVC Insulated PVC Sheathed Copper Tape Screened, Steel Armored Control Cable.
Yslycy-Oz, Control Cable, 300/500 V, Flexible Cu/PVC/PVC/Tcwb/PVC (VDE 0281-13)
Flame Retardant Plastic Insulated Control Cable
450/750V PVC Insulated Al Foil Sheathed Sta Copper Conductor Electrical Control Cable
Popular zzhongdacable Products
2-2-2 Clam Aluminum Triplex Overhead Conductor Service Drop Cable
Competitive Price 4 Core Power Cable Underground Steel Tape Armoured Power Cables 120mm2
PE Poly XLPE 336.4mcm ACSR Conductor Insulated for 11kv 15kv 25kv 33kv Line
Copper Conductor XLPE PVC 185mm 150mm 120mm 95mm 70mm 3 Core Armoured Cable Price
0.6/1kv Aluminum Core or ACSR Core Single Core Aerial Cable
Fils Souple H07vk H05vk Electrical Wire 1.0 1.5 2.5 4 6
Tags: 24*1.0 24*1.5 24*2.5 Copper Control Cable, 24*1.0 Control Cable, Control Cable, zzhongdacable