3*25+54.6+1*16 Aluminum Cable Twisted Overhead Cable

China 
                        3*25+54.6+1*16 Aluminum Cable Twisted Overhead Cable
                      manufacture and supplier

3*25+54.6+1*16 Aluminum Cable Twisted Overhead Cable image

Get Latest Price Request a quote

Quick Details

3*25+54.6+1*16 Aluminum Cable Twisted Overhead Cable

OEM

ABC

ISO, CCC

Aluminum and All Alloy Aluminum

Round Wire

No Jacket

XLPE

DC Cable

Low and Medium Voltage Cable

Overhead

NFC 33209

Aluminum and All Alloy Conductor

NO

in Drum or in Pallent

3*70+54.6+1*16

Henan

8544492100

Product Details

Application

Aerial Bundled Cable (ABC cable) has characters of power-transmitting and strong mechanical. In comparison with bare wire, aerial bundled cable (ABC cable) boasts many advantages, such as: small span in laying, higher safe reliability, better atmosphere aging resistence property. Aerial bundled cable has the priority to be used in urban and rural power-transmitting construction project.
 
Advantages

In comparison to bare overhead distribution lines, AB Cables have very high reliability during the services. As the power and neutral conductors are insulated with the best dielectric material, resulting in the following
Less fault rate on account of good protection against line and ground fault by high winds or falling trees or birds especially in hilly areas & forests as encountered in Rural distribution networks
High Insulation resistance to earth in all polluted atmosphere. Negligible currents and low losses
Multiple circuits of Power and Telephone Cables could be strung in the same set of poles or any other supports like walls etc
Better adaptability to run concurrently with existing over-head bare conductor system without any interference
High capacitance and low inductance leading to low impedance of lines
Lower voltage drop, higher current carrying capacities, vis-a-vis better Voltage Regulation
Longer spans and longer distance lines are possible with better systems stability
ABC  Cables are much safer then bare Conductors
It can be over hung in dense vegetation and forests
Additional connections can be easily and quickly made with hot-line connectors
Total lines costs are reduced
Maintenance costs are reduced
Very difficult to tap the AB cables, thus reducing theft which leads to lower distribution loses

Construction

SPEC
mm2
Conductor structure  Insulation
Material
Insulation
Thickness
(mm)
Approx overall diameter
(mm)
Approx weight
(kg/km)
Phase (compacted Al) Neutral
(alloy)
No./mm No./mm
1*16+1*16 7/1.72 7/1.72 XLPE
Or 
PVC
or 
PE 
 
 
1.2 12.5 110.1
1*25+1*25 7/2.15 7/2.15 1.2 14.9 163.9
1*35+1*35 7/2.54 7/2.54 1.4 17.5 229.0
1*50+1*50 7/2.92 7/2.92 1.4 20.1 300.0
1*70+1*70 19/2.15 19/2.15 1.4 23.6 423.2
1*95+1*95 19/2.54 19/2.54 1.6 27.6 585.4
2*16+1*16 7/1.72 7/1.72 1.2 14.2 175.8
2*25+1*25 7/2.15 7/2.15 1.2 16.7 258.4
2*35+1*35 7/2.54 7/2.54 1.4 19.7 361.2
2*50+1*50 7/2.92 7/2.92 1.4 22.5 472.1
2*70+1*70 19/2.15 19/2.15 1.4 26.1 658.3
2*95+1*95 19/2.54 19/2.54 1.6 30.5 908.2
3*16+1*16 7/1.72 7/1.72 1.2 16.3 241.5
3*25+1*25 7/2.15 7/2.15 1.2 19.1 353.6
3*35+1*35 7/2.54 7/2.54 1.4 22.5 493.5
3*50+1*50 7/2.92 7/2.92 1.4 25.7 644.1
3*70+1*70 19/2.15 19/2.15 1.4 29.7 895.2
3*95+1*95 19/2.54 19/2.54 1.6 34.6 1233.5

We are China 3*25+54.6+1*16 Aluminum Cable Twisted Overhead Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 3*25+54.6+1*16 Aluminum Cable Products

  • No related articles
  • Popular NFC 33209 Standard Cable Products

    3*35+54.6+2*16 ABC Aluminum Overhead Cable XLPE/PE Insulated Cable

    4*70 ABC Aluminum Insulated Cable Areal Bundle XLPE Cable

    3*50+54.6+1*16 ABC Aluminum Insulated Cable

    4*10 Aluminum Insulated XLPE/PE ABC Cable Service Aluminum Cable

    Aluminum Cable 4*16 NFC 33209 Standard

    3*95+54.6+2*16 Aluminum Cable ABC Insulated Cable

    Popular Twisted Overhead Cable Products

    3*35+54.6 ABC Aluminum Twisted Overhead Cable

    Popular zzhongdacable Products

    ASTM Standard Soft Medium Hard Drawn Bare Copper Conductor 2AWG 1/0AWG

    Ttu Conductor Mono Polar Tipo Ttu 500 Mcm 600 V 90c

    12kv 33kv Sac Cable Single Core Aluminum Sac Cable 150 185 240mm

    DC Armoured Cable Sta 4 Core 16mm2 Steel Tape Armoured Cable 0.6/1kv LV Power Cable

    2*70+1*54.6 ABC Aluminum Cable XLPE Insulated Cable

    U1000 Arvfv Aluminum Armored Underground Cable 4*70 4*95 4*120 4*150

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION