Product Details

Cable Solidal Aluminium 16sqmm Single core With 4 Insulated Copper Communication Core Overhead Concentric Service Cable

1 Applications

The concentric cable is used as electric service entrance from the power distribution network until the meter panel (especially where it is required to prevent "black" losses or electric power robbery), and as feeder cable from the meters panel until the panel or general distribution panel, just as it is specified in the National Electrical Code.

This type of conductor can be used in dry and wet places, directly buried or outdoors; its maximum temperature of operation is 70 ºC and its voltage of service for all the applications is 600 V.

Standards: IEC BS and so on

Voltage: 600/1000V

Concentric Cable Construction

Conductor

Aluminum conductors, IEC 60228, solid or stranded versions, conductor types

10-16 mm² round, solid conductors.

10-25 mm², stranded conductor.

35-240 mm², sector shaped conductor, stranded

Insulation: XLPE

Inner Sheath: PVC(Polyvinyl Chloride)

Concentric Conductor: Aluminum wires+4 core insulated copper wire

Sheath: PVC(Polyvinyl Chloride)

Minimum Bending Radius

Single Core: 15* overall diameter

Multi Core: 12* overall diameter

These cables are used for power supplies with Protective Multiple Earthing (PME) systems, where a combined Protective Earth (PE) and Neutral (N) – together known as the PEN – connects the combined neutral-and-earth to real earth at multiple locations to reduce the risk of electric shock in the event of a broken PEN.

Construction of One Type Concentric Cable:

 

   1- Phase conductor: Solid aluminum / copper conductor

   2- Phase Insulation: XLPE / PVC 

   3- Pilot Core Conductor: Plain annealed copper wire

   4- Pilot Core Insulation: PE (Poly Ethylene compounds)

   5- Neutral Core: Solid aluminum conductor 

   6- Wraping tape

   7- Ripcord

   8- Outer sheath: PVC / PE 

Concentric Split single phase service cable, 4mm to 35mm Plain annealed stranded copper phase conductor,XLPE insulated surrounded by a concentric layer of plain annealed solid copper neutral conductors.XLPE insulated and plain annealed solid strand bare copper earth conductors,PVC outer sheath. Black.600/1000 voltsgrade to BS7870.

Choose a cable type

CCC Code Conductor size
(MM2)
Stranding Cores Weight
(KG/KM)
Overall
Diameter (MM)
Gland
Size
Cleat Trefoil
Cleat
4SPLITCON 4 7/0.85 1 206 9.6 20S
6SPLITCON 6 7/1.04 1 281 11.4 20
10SPLITCON 10 7/1.35 1 394 12.7 20
16SPLITCON 16 7/1.70 1 583 14.6 25
25SPLITCON 25 *7/2.14 1 843 18.7 32
35SPLITCON 35 7/2.52 1 1300 23 40

 

2.Technical data

Electrical Information

Cable Size (mm2) 10 16
Phase Conductor Resistance (Ohm/km) DC @ 20°C 1,90 1,90
Phase Size (mm2) 7,5 10
Neutral Size (mm3) 10 16
Phase Core Impedance (Z) (Ohm/km) 2,34 1,47
Current Rating* (A) 50 70
Pilot Cores (No. x OD) Solid (mm) 2 x 1,13 2 x 1,13
In air, with 30°C ambient with maximum conductor temperature 90°C

 

Mechanical Information    
Cable Size (mm2) 10 16
Phase Conductor (No. x OD)(mm) 7 x 1,35 7 x 1,67
Nominal Insulation Thickness (mm) 1,0 1,0
Neutral Conductor (No. x OD)(mm) 7 x 1,33 7 x 1,76
Earth Conductor (No. x OD)(mm) 3 x 1,78 3 x 2,20
Nominal Sheath Thickness (mm) 1,6 1,6
Approximate Cable OD (mm) 12,8 14,5
Approximate Cable Mass (kg/km) 320 4

Conductor identification : Brown live/Blue neutral.
Should not be installed at temperatures below 0oc or above + 60oc
.Also available in Violet outer sheath in 6mm, 10mm, 16mm & 25mm.

 Packaging&Delivery

   
Packaging Details:
Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 20 days(detailly depend on the order quantity)
 

Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with Vivian Yuan
Mobile :+86 15838290725

We are China 16sqmm Single Core Cable Solidal Concentric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Airdac Sne Cable Products

Airdac Sne Cable Concentric Cable

10mm2 16mm2 Airdac Sne Concentric Neutral Cable AAAC AAC Conductor

BS Standard Concentric Conductor Combined Neutral and Earth (CNE) with Communication Wire Bare Copper Airdac Sne Cable

16mm2 Aerial Service Concentric Neutral Cable with Pilot Communication Wire

Hongda 2*8 AWG Aluminum Conductor Concentric Service Cable Solidal Cable

10mm 16mm Airdac Sne Concentric Neutral Cable AAAC AAC Conductor

Popular Concentric Cable Products

Copper or Aluminum or 8000 Series Aluminum Alloy Conductor Concentric Cable

600V XLPE Insulated Concentric Cable Aluminium Conductor of Concentric Cable

16mm2 Aerial Service Concentric Neutral Cable with Copper Pilot Communication Wire Sne Cne Airdac Cable Factory Price

Concentric Solidal Cables 16mm2 with 4 Core Copper Communication

Service Entrance Cable Copper Conductor 2 Core Concentric Electric Cable

LV XLPE Insulated Sheath Copper Concentric Cable

Popular Concentric Service Cable Products

35kv Cu Single Core Concentric Cable

5-46kV MV Concentric Cable 2/0AWG Full Natural Cable with Aluminum Conductor

Aluminum or Copper Mv Concentric Neutral Cable 4/0AWG

5kv, 15kv Copper/Aluminium 750mcm Mv Concentric Neutral Cable

Full Neutral, Reduced Neutral 1/3 Neutral, Mv Concentric Cable

PVC XLPE Insulated Aluminum Split Aerial Concentric Service Cable with Communication Wire

Popular zzhongdacable Products

4mm, 10mm Airdac II Cne Cables House Service Connection Cable

18/30 Kv Rhz1-Ol Low Fire Hazard Cables for Power Distribution

Cable Axmk 4X35 4X50 4X95 4X120 0.6/1 Kv XLPE Power Cable

95mm 120mm 150mm 185mm 240mm2 XLPE Insulated PVC Sheath Aluminum Cable

0.6/1kV Single Core Copper XLPE Insulated Power Cable for Underground

Covered Line Wire ACSR/AAC/AAAC XLPE or PE Insulated Aluminum

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION