ASTM Standard XLPE Insulated Service Cable Sdw Cable
ASTM Standard XLPE Insulated Service Cable Sdw Cable image
Get Latest Price Request a quote
Quick Details
Product Details
1. 0.6/1kV, ASTM Standard XLPE Insulated Service Cable Sdw Cable
1.1 Application
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)
1.2 Construction:
| Conductor Phase | Stranded All Aluminium conductor (AAC) |
| Neutral/Messenger | Stranded All Alloy Aluminium Conductor (AAAC) |
| Insulation | Extrude of XLPE, capable for continous operation at maximum cable’s temperature. |
| Item # | Phase conductor size AWG | Phase conductor stranding | Phase conductor Insulation Thickness | Bare Neutral Messenger Size AWG | Bare Neutral Messenger Stranding | Bare Neutral Messenger breaking strength | Weight Per 1000ft-XLP | Weight Per 1000ft-Poly | Ampacity -XLP | Ampacity -Poly |
| Clydesdale | 4 | 7/w | 45 mls | 4 | 7 | 881 Lbs | 208 Lbs | 201.8 Lbs | 100 Amps | 80 Amps |
| Pinto | 4 | 7/w | 45 mls | 4 | 7 | 881 Lbs | 223 Lbs | 207.9 Lbs | 100 Amps | 80 Amps |
| Mustang | 2 | 19/w | 45 mls | 2 | 7 | 1350 Lbs | 333 Lbs | 312.6 Lbs | 135 Amps | 105 Amps |
| Criollo | 1/0 | 19/w | 60 mls | 1/0 | 7 | 1990 Lbs | 529 Lbs | 504.5 Lbs | 180 Amps | 140 Amps |
| Percheron | 2/0 | 19/w | 60 mls | 2/0 | 7 | 2510 Lbs | 649 Lbs | 620.5 Lbs | 205 Amps | 160 Amps |
| Hanoverian | 3/0 | 19/w | 60 mls | 3/0 | 19 | 3310 Lbs | 799 Lbs | 765.6 Lbs | 235 Amps | 185 Amps |
| Oldenburg | 4/0 | 19/w | 60 mls | 4/0 | 19 | 4020 Lbs | 986 Lbs | 946.7 Lbs | 275 Amps | 210 Amps |
| Morochuca | 6 | 7/w | 45 mls | 6 | 6/1 | 1190 Lbs | 152 Lbs | 147.4 Lbs | 75 Amps | 60 Amps |
| Chola | 6 | Solid | 45 mls | 6 | 6/1 | 1190 Lbs | 162 Lbs | 151.7 Lbs | 75 Amps | 60 Amps |
| Morgan | 4 | 7/w | 45 mls | 4 | 6/1 | 1860 Lbs | 226 Lbs | 220 Lbs | 100 Amps | 80 Amps |
| Hackney | 4 | 7/w | 45 mls | 4 | 6/1 | 1860 Lbs | 241 Lbs | 226.1 Lbs | 100 Amps | 80 Amps |
| Palomino | 2 | 19/w | 45 mls | 2 | 6/1 | 2850 Lbs | 362 Lbs | 342.6 Lbs | 135 Amps | 105 Amps |
| Costena | 1/0 | 19/w | 60 mls | 1/0 | 6/1 | 4380 Lbs | 575 Lbs | 550.6 Lbs | 180 Amps | 140 Amps |
| Grullo | 2/0 | 19/w | 60 mls | 2/0 | 6/1 | 5310 Lbs | 707 Lbs | 678.7 Lbs | 205 Amps | 160 Amps |
| Suffolk | 3/0 | 19/w | 60 mls | 3/0 | 6/1 | 6620 Lbs | 872 Lbs | 838.9 Lbs | 235 Amps | 185 Amps |
| Appaloosa | 4/0 | 19/w | 60 mls | 4/0 | 6/1 | 8350 Lbs | 1079 Lbs | 1039.2 Lbs | 275 Amps | 210 Amps |
| Bronco | 336.4 | 19/w | 80 mls | 336.4 | 6/1 | 8580 Lbs | 1613 Lbs | 1568.2 Lbs | 370 Amps | 280 Amps |
| Gelding | 336.4 | 19/w | 80 mls | 4/0 | 6/1 | 8350 Lbs | 1548 Lbs | 1494.3 Lbs | 370 Amps | 280 Amps |
| Bay | 6 | Solid | 45 mls | 6 | 7 | 1110 Lbs | 145 Lbs | 140.0 Lbs | 75 Amps | 60 Amps |
| French Coach | 6 | 7/w | 45 mls | 6 | 7 | 1110 Lbs | 155 Lbs | 144.3 Lbs | 75 Amps | 60 Amps |
| German Coach | 4 | Solid | 45 mls | 4 | 7 | 1760 Lbs | 214 Lbs | 208.3 Lbs | 100 Amps | 80 Amps |
| Arabian | 4 | 7/w | 45 mls | 4 | 7 | 1760 Lbs | 229 Lbs | 214.4 Lbs | 100 Amps | 80 Amps |
| Belgian | 2 | 7/w | 45 mls | 2 | 7 | 2800 Lbs | 344 Lbs | 323.1 Lbs | 135 Amps | 105 Amps |
| Shetland | 1/0 | 19/w | 60 mls | 1/0 | 7 | 4460 Lbs | 546 Lbs | 521.1 Lbs | 180 Amps | 140 Amps |
| Thoroughbred | 2/0 | 19/w | 60 mls | 2/0 | 7 | 5390 Lbs | 670 Lbs | 641.5 Lbs | 205 Amps | 160 Amps |
| Trotter | 3/0 | 19/w | 60 mls | 3/0 | 7 | 6790 Lbs | 825 Lbs | 791.8 Lbs | 235 Amps | 185 Amps |
| Walking | 4/0 | 19/w | 60 mls | 4/0 | 7 | 8560 Lbs | 1019 Lbs | 979.7 Lbs | 275 Amps | 210 Amps |
1.3 Classification:
Low Voltage Cable Aerial Bundled Conductor, Twisted Cable
| Physical Properties | ||||||||
| Cable size | Insulation Thickness | Approx Maximum Diameter | Approx. Net. Weight | Standard Length | ||||
| Phase | Neutral / Messenger | Public Lighting | Phase | Neutral/Messenger | Public Lighting | |||
| mm2 | mm | mm | mm | mm | mm | mm | kg/km | m |
| 2×25+25 | 1.4 | 1.4 | – | 10.0 | 10.0 | 10.0 | 338 | 500 |
| 2×35+25 | 1.6 | 1.4 | – | 11.2 | 10.0 | 10.0 | 394 | 500 |
| 2×50+35 | 1.6 | 1.6 | – | 12.6 | 11.2 | 11.2 | 526 | 500 |
| 2×70+50 | 1.8 | 1.6 | – | 15.4 | 12.6 | 12.6 | 760 | 500 |
| 2×95+70 | 2.0 | 1.8 | – | 17.0 | 15.4 | 15.4 | 975 | 500 |
| 3×25+25 | 1.4 | 1.4 | – | 10.0 | 10.0 | 10.0 | 452 | 500 |
| 3×35+25 | 1.6 | 1.4 | – | 11.2 | 10.0 | 10.0 | 537 | 500 |
| 3×50+35 | 1.6 | 1.6 | – | 12.6 | 11.2 | 11.2 | 717 | 500 |
| 3×70+50 | 1.8 | 1.6 | – | 15.4 | 12.6 | 12.6 | 1057 | 500 |
| 3×95+70 | 2.0 | 1.8 | – | 17.0 | 15.4 | 15.4 | 1360 | 500 |
| 3×25+25+2×16 | 1.4 | 1.4 | 1.2 | 10.0 | 10.0 | 8.1 | 602 | 500 |
| 3×35+25+2×16 | 1.6 | 1.4 | 1.2 | 11.2 | 10.0 | 8.1 | 687 | 500 |
| 3×50+35+2×16 | 1.6 | 1.6 | 1.2 | 12.6 | 11.2 | 8.1 | 867 | 500 |
| 3×70+50+2×16 | 1.8 | 1.6 | 1.2 | 15.4 | 12.6 | 8.1 | 1207 | 500 |
| 3×95+70+2×16 | 2.0 | 1.8 | 1.2 | 17.0 | 15.4 | 8.1 | 1510 | 500 |
| 3×25+25+16 | 1.4 | 1.4 | 1.2 | 10.0 | 10.0 | 8.1 | 527 | 500 |
| 3×35+25+16 | 1.6 | 1.4 | 1.2 | 11.2 | 10.0 | 8.1 | 612 | 500 |
| 3×50+35+16 | 1.6 | 1.6 | 1.2 | 12.6 | 11.2 | 8.1 | 792 | 500 |
| 3×70+50+16 | 1.8 | 1.6 | 1.2 | 15.4 | 12.6 | 8.1 | 1132 | 500 |
| 3×95+70+16 | 2.0 | 1.8 | 1.2 | 17.0 | 15.4 | 8.1 | 1435 | 500 |
2. NF2X / NFA2X
Aerial Bundled Conductor , Twisted Cable
2.1 Application:
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)
2.2 Construction
| Conductor | NF2X : Stranded Copper Conductor NFA2X : Stranded All Aluminium Conductor (AAC) |
| Insulation | Extrude of XLPE |
2.3 Classification
Low Voltage Cable
| Physical Properties | Electrical Properties | ||||||
| Cable Size | Insulation Thickness | Approx. Twisted Diameter | Approx. Net. Weight | Max. Conductor Resistance at 20ºC | Current Carrying Capacity at 35ºC | Calculated Breaking Force | Standard Length |
| mm2 | mm | mm | kg/km | ohm/km | A | kg | m |
| NF2X (Copper Conductor) | |||||||
| 2×6 rm | 1.2 | 13.0 | 136 | 3.080 | 54 | 394 | 2000 |
| 2×10 rm | 1.2 | 14.0 | 211 | 1.830 | 73 | 656 | 2000 |
| 2×16 rm | 1.2 | 16.0 | 334 | 1.150 | 97 | 1051 | 1000 |
| 4×6 rm | 1.2 | 15.7 | 258 | 3.080 | 54 | 788 | 1000 |
| 4×10 rm | 1.2 | 17.0 | 422 | 1.830 | 73 | 1312 | 1000 |
| 4×16 rm | 1.2 | 19.0 | 664 | 1.150 | 97 | 2102 | 1000 |
| 4×25 rm | 1.4 | 24.0 | 1008 | 0.727 | 133 | 3284 | 1000 |
| NFA2X (All Aluminum Conductor) | |||||||
| 2×10 rm | 1.2 | 14.0 | 94 | 3.080 | 54 | 322 | 2000 |
| 2×16 rm | 1.2 | 16.0 | 138 | 1.910 | 72 | 515 | 1000 |
| 4×10 rm | 1.2 | 17.0 | 187 | 3.080 | 54 | 644 | 1000 |
| 4×16 rm | 1.2 | 19.0 | 272 | 1.910 | 72 | 1030 | 1000 |
| 4×25 rm | 1.4 | 24.0 | 423 | 1.200 | 102 | 1610 | 1000 |
| 4×35 rm | 1.6 | 27.0 | 564 | 0.868 | 125 | 2250 | 1000 |
*Further information about rating factor for certain cable arrangement can be found on supplementary technical information.
For more information, don’t hesitate to contact us on +86-15838290725
We are China ASTM Standard XLPE Insulated Service Cable Sdw Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Triplex Service Drop Aerial Bundle Cable 2/0AWG ABC Cable
Aluminium 11kv Price List of Aerial Bundled Cable ABC Concentric Cable
Al /XLPE Insulated Aerial Bundled ABC Cable
Direct Manufacturer Supply ABC Aerial Bundled Cable
0.6/1kv Oyster Triplex Service Drop Cable 2 AWG Duplex Quadplex Overhead ABC Cable
AAC/ACSR/AAAC Core Overhead Aerial Bundled Cable ABC Cable
Popular Aerial Bundled Cable Products
0.6/1kv Apricot Core AAC Conductor XLPE/PE Insulated Overhead Cable
2/0 AWG Service Drop Cable Twisted Aluminum ABC Cable
IEC BS Standard 3*50+50 ABC Cable
NFC 33-209 ABC Cable 3*95mm2+1*70mm2
Low Voltage Twisted 4X16mm2 NF2X Service Cable for Overhead Line
0.6/1kv Al XLPE/Aerial Bundled/ABC Cable for Aluminum
Popular Twisted Cable Products
Bt Connection Cable XLPE Insulated 2X16mm2 Aluminum Twisted Aerial Cable
Aluminum Conductor Shepherd XLPE Insulation Twisted Overhead Cable Duplex ABC Cable
300 V Twisted Flexible Parallel Cable House Wire
Aluminum Twisted ABC Cable 600/1000V Overhead Cable
Popular zzhongdacable Products
Cable U-1000 Rvfv & Vvfv / Rvfv-K & Vvfv-K Steel Tape / Aluminum Tape Armoured Cable
3X1.5mm2 450/750V Installation Power Cable Cyky
3 Core Nym-J 3X2, 5 PVC Installation Power Supply Cable
4 Core ABC Cable Aluminum 35mm2 16mm2 AAC Conductor
XLPE/PVC/Awa/PVC (N2XRY) 240mm2 X 1 Core Rigid Cable
Bare Aluminum Conductor South Africa Bright Cable Wire
Tags: ABC Cable, Aerial Bundled Cable, Twisted Cable, zzhongdacable