4 Core 50mm 70mm2 95mm2 ABC Service Drop Aerial Bundled Cable
4 Core 50mm 70mm2 95mm2 ABC Service Drop Aerial Bundled Cable image
Get Latest Price Request a quote
Quick Details
Product Details
4 Core 50 mm 70mm2 95mm2 ABC Service Drop Aerial Bundled Cable
Aerial Bundle Conductor (ABC)
Description
Cable Description
Self-supporting system consists of four cores of hard-drawn stranded and compacted aluminium conductors of equal cross-section and insulated with carbon-loaded XLPE to ensure UV protection. All cores strained equally. Supporting-core system consists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon-loaded XLPE laid up around an aluminium-alloy supporting core insulated with carbon loaded XLPE to ensure UV protection. Additional sub-conductors optional in both self-supporting-core systems.
Installation Information
· Economical
· Flexible
· Safe
· Vandal proof
· Durable
· Aesthetically pleasing
· Adaptable
Technical Data
| Rated voltage | kV | 0.6/1 |
| Test voltage | Veff kV | 4 |
| Laying temperature | °C | min. -20 |
| Operating temperature | °C | -30 ~ +80 |
| Conductor temperature | °C | max. +80 |
| Short-circuit temperature | °C/s | max. +130 /5 |
| Bending radius (min.) | 18 × o of cable |
Aerial Bundle Conductor (ABC) Application
Bundle conductor for overhead distribution network without and with public lighting. (between pole to pole)
Construction:
| Conductor Phase | Stranded All Aluminium conductor (AAC) |
| Neutral/Messenger | Stranded All Alloy Aluminium Conductor (AAAC) |
| Insulation | Extrude of XLPE, capable for continous operation at maximum cable’s temperature. |
Properties:
Aluminum XLPE cable Insulated Overhead ABC Cable
| number of cores x nominal cross section | max. conductor- resistance | min. breaking load of conductor strand | Current rating in the air | Outer diameter | Total weight |
|---|---|---|---|---|---|
| mm^2 | Ohm/km | kN | A | mm | kg/km |
| 1x 16 RM | 1,910 | 2,5 | 72 | 80 | 74 |
| 1x 25 RM | 1,200 | 4,0 | 107 | 90 | 106 |
| 1x 35 RM | 0,868 | 5,5 | 132 | 105 | 138 |
| 1x 50 RM | 0,641 | 8,0 | 165 | 118 | 182 |
| 1x 70 RM | 0,443 | 10,7 | 205 | 130 | 252 |
| 1x 95 RM | 0,320 | 13,7 | 240 | 154 | 333 |
| 1x 120 RM | 0,253 | 18,6 | 290 | 170 | 408 |
| 1x 150 RM | 0,206 | 23,2 | 334 | 190 | 502 |
| 1x 185 RM | 0,164 | 28,7 | 389 | 210 | 611 |
| 1x 240 RM | 0,125 | 37,2 | 467 | 240 | 801 |
| 2x 16 RM | 1,910 | 2,5 | 72 | 156 | 147 |
| 2x 25 RM | 1,200 | 4,0 | 107 | 180 | 208 |
| 2x 35 RM | 0,868 | 5,5 | 132 | 200 | 277 |
| 2x 50 RM | 0,641 | 8,0 | 165 | 235 | 361 |
| 2x 70 RM | 0,443 | 10,7 | 205 | 254 | 505 |
| 2x 95 RM | 0,320 | 13,7 | 240 | 303 | 666 |
| 2x 150 RM | 0,206 | 23,2 | 334 | 380 | 1004 |
| 4x 16 RM | 1,910 | 2,5 | 72 | 188 | 286 |
| 4x 25 RM | 1,200 | 4,0 | 107 | 212 | 430 |
| 4x 35 RM | 0,868 | 5,5 | 132 | 241 | 553 |
| 4x 50 RM | 0,641 | 8,0 | 165 | 278 | 746 |
| 4x 70 RM | 0,443 | 10,7 | 205 | 318 | 1009 |
| 4x 95 RM | 0,320 | 13,7 | 240 | 378 | 1332 |
| 4x 120 RM | 0,253 | 18,6 | 290 | 544 | 1632 |
| 4x 50 + 1x 25 RM | 0,641/1,200 | 8,0/4,0 | 165/107 | 319 | 814 |
| 4x 50 + 1x 35 RM | 0,641/0,868 | 8,5/5,5 | 165/132 | 319 | 845 |
| 4x 70 + 1x 25 RM | 0,443/1,200 | 10,7/4,0 | 205/107 | 360 | 1105 |
| 4x 70 + 2x 25 RM | 0,443/1,200 | 10,7/4,0 | 205/107 | 400 | 1217 |
| 4x 95 + 1x 25 RM | 0,320/1,200 | 13,7/4,0 | 240/107 | 418 | 1438 |
| 4x 95 + 2x 25 RM | 0,320/1,200 | 13,7/4,0 | 240/107 | 420 | 1544 |
| 4×120 + 1x 25 RM | 0,253/1,200 | 18,6/4,0 | 290/107 | 590 | 2050 |
other cross-sections on request of Aerial Bundle Conductor (ABC)
| Physical Properties | ||||||||
| Cable size | Insulation Thickness | Approx Maximum Diameter | Approx. Net. Weight | Standard Length | ||||
| Phase | Neutral / Messenger | Public Lighting | Phase | Neutral/Messenger | Public Lighting | |||
| mm2 | mm | mm | mm | mm | mm | mm | kg/km | m |
| 2×25+25 | 1.4 | 1.4 | – | 10.0 | 10.0 | 10.0 | 338 | 500 |
| 2×35+25 | 1.6 | 1.4 | – | 11.2 | 10.0 | 10.0 | 394 | 500 |
| 2×50+35 | 1.6 | 1.6 | – | 12.6 | 11.2 | 11.2 | 526 | 500 |
| 2×70+50 | 1.8 | 1.6 | – | 15.4 | 12.6 | 12.6 | 760 | 500 |
| 2×95+70 | 2.0 | 1.8 | – | 17.0 | 15.4 | 15.4 | 975 | 500 |
| 3×25+25 | 1.4 | 1.4 | – | 10.0 | 10.0 | 10.0 | 452 | 500 |
| 3×35+25 | 1.6 | 1.4 | – | 11.2 | 10.0 | 10.0 | 537 | 500 |
| 3×50+35 | 1.6 | 1.6 | – | 12.6 | 11.2 | 11.2 | 717 | 500 |
| 3×70+50 | 1.8 | 1.6 | – | 15.4 | 12.6 | 12.6 | 1057 | 500 |
| 3×95+70 | 2.0 | 1.8 | – | 17.0 | 15.4 | 15.4 | 1360 | 500 |
| 3×25+25+2×16 | 1.4 | 1.4 | 1.2 | 10.0 | 10.0 | 8.1 | 602 | 500 |
| 3×35+25+2×16 | 1.6 | 1.4 | 1.2 | 11.2 | 10.0 | 8.1 | 687 | 500 |
| 3×50+35+2×16 | 1.6 | 1.6 | 1.2 | 12.6 | 11.2 | 8.1 | 867 | 500 |
| 3×70+50+2×16 | 1.8 | 1.6 | 1.2 | 15.4 | 12.6 | 8.1 | 1207 | 500 |
| 3×95+70+2×16 | 2.0 | 1.8 | 1.2 | 17.0 | 15.4 | 8.1 | 1510 | 500 |
| 3×25+25+16 | 1.4 | 1.4 | 1.2 | 10.0 | 10.0 | 8.1 | 527 | 500 |
| 3×35+25+16 | 1.6 | 1.4 | 1.2 | 11.2 | 10.0 | 8.1 | 612 | 500 |
| 3×50+35+16 | 1.6 | 1.6 | 1.2 | 12.6 | 11.2 | 8.1 | 792 | 500 |
| 3×70+50+16 | 1.8 | 1.6 | 1.2 | 15.4 | 12.6 | 8.1 | 1132 | 500 |
| 3×95+70+16 | 2.0 | 1.8 | 1.2 | 17.0 | 15.4 | 8.1 | 1435 | 500 |
*Further information about rating factor for certain cable arrangement can be found on supplementary technical information
We are China 4 Core 50mm 70mm2 95mm2 ABC Service Drop Aerial Bundled Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundled ABC Cable Products
NFC 33209 3X70+54.6+2X16mm2 Aluminum XLPE Insulated Aerial Bundled ABC Cable
IEC60502 Standard Overhead ABC Aluminum 600V Aerial Bundled Cable for Malaysia
Low Voltage Overhead 2/3/4/5 Cores Aerial Bundled ABC Cable
Electric 600V XLPE Insulated Aluminum Conductor 6/4/2AWG Duplex Service Drop Cable
Bare Aluminum 0.6-1kv AAC/AAAC/ACSR Conductor Service Drop Duplex Cable Wire
Popular Aerial Bundled Cable Products
ABC Cable, 1core/ 2core/ 3core/ 4core, 0.6/1kv Copper Conductor PVC Insulated Aerial Bundled Cable
Street Lighting Overhead Aerial Bundled Cable
ABC Cable with XLPE Insulation Aluminum Conductor
0.6/1kv 5X35mm2 Al/XLPE/PVC Electric ABC Cable
3X25+54.6+1X16mm2 Overhead Stranded Wire ABC Cable NFC Standard
LV Multi-Core Stranded Overhead Cluster ABC Cable
Popular XLPE ABC Cable Products
0.6/1kv XLPE ABC Cable Aluminum Overhead Cable
Service Drop Cable Aerial Bundled Cable Twisted Aluminum ABC Cable
Factory Price Low Voltage Al Conductor XLPE Insulated Aerial Bundled Cable
Aluminum Conductor XLPE Insulation 11kv ABC Cable
2X16mm2 Aluminum Conductor XLPE Insulated Twisted Duplex ABC Cable 0.6/1kv
Overhead Aerial Bundle XLPE /PE ABC Cable
Popular zzhongdacable Products
Na2xy Al XLPE PVC Single Core 500mm Aluminum Power Cable 1X500mm2
2 Core Silicone Cable Ygg Multicore 2X1.5 High Temperature Fire Proof
PVC Insulation 7 Wire Stranded Copper Conductor Wire Cable Thw 12 AWG 600V
0.6/1kv Low Voltage Copper or Aluminum Conductor XLPE Insulated Armored Power Cable
1000V 16mm2 Solid Aluminum Conductor Cne / Sne Concentric Neutral Cable
Tags: Aerial Bundled ABC Cable, Aerial Bundled Cable, XLPE ABC Cable, zzhongdacable