Copper Conductor Armored 11kv 3 Core 240mm Mv Cable

China 
                        Copper Conductor Armored 11kv 3 Core 240mm Mv Cable
                      manufacture and supplier

Copper Conductor Armored 11kv 3 Core 240mm Mv Cable image

Get Latest Price Request a quote

Quick Details

Copper Conductor Armored 11kv 3 Core 240mm Mv Cable

11kV 3 core 240mm cables

Hongda

YJV

ISO, CCC

Bare Copper Wire

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Underground, Industrial, Power Station

25kv

Hongda, accept OEM

Steel & Wooden Drum or Customer Requirement

25mm2 to 400mm2

China

8544601200

Product Details

copper conductor armored 11kV 3 core 240mm MV cable

Three Core Cables to BS 6622/BS 7835

APPLICATIONS
The three core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV and frequency 50Hz.
They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

STANDARD
BS 6622
BS 7835 (LSZH Version)

CONSTRUCTION

 

Conductor Plain annealed copper or aluminium complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2).
Conductor Screen Extruded layer of semi-conducting cross-linkable compound is applied over the conductor and shall cover the surface completely. The minimum thickness is 0.3mm and the maximum resistivity shall not exceed 500 Ohm-m at 90°C.
Insulation Insulation is of cross-linked polyethylene compound XLPE or EPR.
Insulation Screen Extruded layer of semi-conducting cross-linkable compound is applied over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site.
Inner Covering & Fillers For cables with a collective metallic layer or cables with a metallic layer over each individual cores with additional collective metallic layers, semi-conducting inner covering and fillers shall be applied over the laid up cores. The inner covering is made of non hygroscopic material, except if the cable is to be made longitudinally watertight. The inner covering shall be extruded or lapped.
Metallic Layer The metallic layer shall be applied over each core or applied as a collective screen. The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires. The metallic layer provides an earth fault current path, capable of withstanding fault current to earth of 1000A for one second at maximum temperature 160°C. Copper wires are applied over the conducting water blocking layer with a minimum diameter of 0.5mm. And over the copper wires, copper tape with minimum thickness of 0.1mm can be applied helically with overlap.
Separation Sheath (for armoured cable) The separation sheath comprises a layer of extruded PVC, PE or LSZH. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. The nominal separation sheath thickness shall not be less than 1.2mm.
Armour (for armoured cable) The armour consists of galvanized steel wire applied over the inner covering
Over Sheath Overall sheath comprises a layer of extruded either PVC or MDPE; LSZH can be offered as an option. The over sheath is normally black in colour. When a DC voltage test is to be performed on the over sheath, a semi-conducting layer such as graphite coating shall be applied over the surface of the extruded over sheath. The nominal over sheath thickness is calculated by 0.035+D where D is the diameter immediately under the over sheath in mm. For cables with the over sheath not applied over the armour, the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour, the nominal over sheath thickness shall not be less than 1.8mm.

PHYSICAL PROPERTIES

Operating Temperature up to 90°C
Temperature Range -5°C ( PVC or LSZH sheath ); -20°C ( PE sheath )
Short Circuit Temperature 250°C (short circuit duration up to 5 seconds)
Bending Radius 15 x OD

Nominal /Operating /Test Voltages

Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage (rms)
3.8/6.6KV 7.2KV 15KV
6.35/11KV 12KV 25.5KV
8.7/15KV 17.5KV 35KV
12.7/22KV 24KV 51KV
19/33KV 36KV 76KV

Three Core 6.35/11KV (Um=12KV)
Dimensional Data

Nom. Cross-Section Area   Unarmoured Cables Steel Wire Armoured Cables
Nom. Insulation Thick. Copper Wire Screen Area Nom. Sheath Thick. Approx. Overall Diameter Approx. Weight Copper Tape Screen Area Nom. Bedding Thick. Nom. Armour Wire Diameter Nom. Sheath Thick. Approx. Overall Diameter Approx. Weight
Cu AL CU AL
mm^2 mm mm2 mm mm kg/km kg/km mm2 mm mm mm mm    
25 3.4 16 2.3 42.8 2600 2120 3.8 1.3 2.5 2.4 50.0 4930 4400
35 3.4 16 2.3 45.3 3000 2320 4.1 1.3 2.5 2.5 52.3 5380 4700
50 3.4 16 2.4 48.5 3630 2690 4.4 1.4 2.5 2.6 55.7 6210 5260
70 3.4 16 2.5 52.0 4440 3110 4.7 1.4 2.5 2.7 59.2 7200 5870
95 3.4 16 2.7 56.0 5440 3620 5.2 1.5 2.5 2.8 63.2 8420 6550
120 3.4 16 2.8 59.4 6370 4020 5.5 1.6 2.5 3.0 67.0 9580 7190
150 3.4 25 2.9 62.7 7430 4630 5.8 1.6 2.5 3.1 70.3 10830 8030
185 3.4 25 3.0 66.1 8680 5150 6.2 1.7 2.5 3.2 73.9 12290 8720
240 3.4 25 3.1 71.7 10690 5990 6.8 1.8 3.15 3.4 81.2 15620 10790
300 3.4 25 3.3 76.4 12770 7050 7.3 1.9 3.15 3.6 86.1 18030 12240
400 3.4 35 3.5 85.1 16460 8680 8.0 2.0 3.15 3.8 95.0 22350 14350

Other standard and specification can be produce depending on customer require.

PACKAGE AND SHIPPING:
Steel wooden drum (fumigation)
Cable length in each drum: 200m/300m or as per actual cable length requirements.
Drum size: As per cable length and container size

Shipping:
Port: Tianjin, Qingdao, or other ports as per your requireents.

Sea freight:
FOB/C&F/CIF quotation are all available.

*In order to quote you accurate price, kindly tell us your needed cable length quantity. Larger quantity, more discount benefit ready for you!
Any needs or question, please contact me Mobile:+86-15838290725 , we will be more pleasure to service you.
We are looking forward to your inquiry and nice cooperation.

We are China Copper Conductor Armored 11kv 3 Core 240mm Mv Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular 11kv 3 Core Cable Products

  • No related articles
  • Popular 11kv Cable Products

    11kv Cable Line Copper Underground 3 Core XLPE Cable Price Cost Per Metre Without Termination

    6.6kv 11kv 22kv 33kv Copper (Aluminum) Conductors XLPE Insulated Medium Voltage Cable

    Medium Voltage 11kv Cable, 3 Core Cable, Armoured Cable

    11kv Cable Steel Wire Armored Cable 3X95mm

    11kv Aluminium Armoured Cable with High Quality

    Mv 11kv Copper Cable, XLPE Power Cable

    Popular Armored Cable Products

    0.6/1kV IEC 60502-1 Armored Electrical Aluminum Power Cable Al/XLPE/SWA/PVC Electric Cable

    Low Voltage Cable 0.6/1kv Steel Wire Armoured 4c95mm2

    Copper Conductor Steel-Tape Armored Power Cable

    U1000 Arvfv Al Conductor Steel Tap Armored Cable

    5core, 70sqmm, Armored XLPE Power Cable

    Aluminum Armor Amoured Cable Power Electric Wire cUL Teck 90 Cables Teck90

    Popular zzhongdacable Products

    0.6/1kv 70mm Copper Cable Prices PVC Insulated Power Cable

    2/0-2/0-2/0-2/0 Grullo Quadruplex Overhead Aluminum Conductor Service Drop Cable

    Nayy-J -O Al PVC PVC 0.6/1kv Direct Burial Underground Power Cable 16mm 50mm 70mm

    NFC-33 209 Aluminum Conductor XLPE PE PVC Insulation 3*25+54.6+16sqmm Overhead ABC Cable

    Fire Resistant Flame Retardant Power Cable Cu Shielded Electrical Cable

    E-Y2y Copper Conductor PVC Insulated PE Outer Sheath Heavy Current Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION