Cvv Control Cable Cvs Cable Cvv-S Cable Cvv-Sb Cable Fr-Cvv Cable Tfr-Cvvs Cable
Cvv Control Cable Cvs Cable Cvv-S Cable Cvv-Sb Cable Fr-Cvv Cable Tfr-Cvvs Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application: Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.
Construction- Conductors:Annealed Copper Wire
– Insulation : PVC
– Core Identification : Coloring Method – below 4 cores
(2 cores – Black, White /3 cores – Black, White, Red )
Numbering Method (Above 5 cores)
– Sheath : PVC
Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS
2 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 2 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 98 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 10.0 | 24.5 | 0.0142 | 110 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 10.5 | 18.1 | 0.0135 | 115 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 11.0 | 12.1 | 0.0115 | 135 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 12.0 | 7.41 | 0.0093 | 180 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 14.5 | 4.61 | 0.0092 | 255 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 15.5 | 3.08 | 0.0078 | 320 | 500/D |
3 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
5 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
9 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
11 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 11 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 255 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 315 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 340 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 425 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 605 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 915 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1220 | 500/D |
12 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 12 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 265 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 320 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 345 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 440 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 630 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 950 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1270 | 500/D |
13 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 13 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 295 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 355 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 380 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 485 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 695 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1050 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1405 | 500/D |
14 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 14 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 300 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 360 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 390 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 495 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 715 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1085 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1455 | 500/D |
15 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 15 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 395 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 425 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 545 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 785 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1195 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1600 | 500/D |
16 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 16 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 400 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 435 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 555 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 805 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1230 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1650 | 500/D |
17 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 17 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 355 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 430 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 465 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 595 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 865 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1315 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1785 | 500/D |
18 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 18 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 360 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 435 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 475 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 605 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 885 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1350 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1835 | 500/D |
19 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 19 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 365 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 445 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 480 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 620 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 905 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1385 | 500/D | |
| 6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1885 | 500/D |
20 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 20 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 390 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 475 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 515 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 665 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 975 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1490 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
21 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 21 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 400 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 490 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 530 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 685 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 1005 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1540 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
22 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 22 | 0.5 | 7/0.30 | 0.8 | 1.8 | 20.0 | 36.0 | 0.0162 | 430 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 520 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 565 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 730 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 265 | 7.41 | 0.0093 | 1070 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1655 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2245 | 500/D |
23 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 23 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.5 | 36.0 | 0.0162 | 440 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 540 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 585 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 755 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 26.5 | 7.41 | 0.0093 | 1105 | 500/D | |
| 4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1710 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
24 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 24 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 460 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.0 | 24.5 | 0.0142 | 560 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 605 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 24.5 | 12.1 | 0.0115 | 785 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.0 | 7.41 | 0.0093 | 1150 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 34.5 | 4.61 | 0.0092 | 1795 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
25 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 25 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 490 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 595 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 645 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 835 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1225 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1915 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2595 | 500/D |
26 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
27 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
28 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 28 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 535 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 650 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 710 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 915 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1350 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2110 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2885 | 500/D |
29 Core CVV Control Cable
| No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
| 29 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
| 0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 660 | 500/D | |
| 1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 715 | 500/D | |
| 1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 930 | 500/D | |
| 2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1370 | 500/D | |
| 4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2145 | 500/D | |
| 6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2940 | 500 |
We are China Cvv Control Cable Cvs Cable Cvv-S Cable Cvv-Sb Cable Fr-Cvv Cable Tfr-Cvvs Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Control Cable Products
Indoor 4-37 Copper Core 0.75-10 Square Millimetre Core PVC Insulated Control Cable Household Wire
Flexible Copper Conductor PVC Insulated Braiding Shielded Control Cable
Control Cable with PVC Insulation and Sheath for Ship
Heat Resistant PVC Sheathed Electrical Wire 1mm Screened Flexible Control Cables
Copper Conductor PVC Insulated Multicore Control Cables, Steel Wire Armored Cable
Popular Fr-Cvv Cable Products
Popular Tfr-Cvvs Cable Products
Popular zzhongdacable Products
0.6/1kv Overhead Aerial Bundled Conductor Twisted Cable Self-Supporting 4X25mm2 NFA2X Cable
BS 6004 6181y 25mm 35mm 50mm PVC Surface Wiring Cable
Yjly23 8.7/10kv 3X240mm Aluminium XLPE Mv Cables Al
Underground Distribution Line Aerial Primary Secondary Cable
Low Voltage 4X240 Cu/XLPE/PVC Cable Copper 240 mm2 Power Cable
Tags: Control Cable, Fr-Cvv Cable, Tfr-Cvvs Cable, zzhongdacable