UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire image
Get Latest Price Request a quote
Quick Details
Product Details
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
Description:
– Model No. : AC10WE32
– Size : #18AWG 34/0.18mm 105°c / 1 core
– Tinned or bare stranded 9-28AWG copper or tinned copper
– PVC insulated
– Temperature: 105 °c ; Voltage: 600Vac
– Use the standard thickness, easy stripping and cutting easy
– with anti-acid. oil resistance. moisture. mildew and other characteristics
– Passes UL VW-1 & CSA FT1 vertical flame test
– OS-1 is available
|
1 |
Model |
AC10WE30 |
||
|
2 |
Standard |
UL/CSA : 105°c, 600 Vac, 750 Vdc, 30# ~ 2,000 kcMil |
||
|
3 |
Construction & Dimension |
|||
|
Item |
Specification |
|||
|
Conductor |
Size |
34/0.18±0.01mm |
||
|
Material |
Annealed Bare Copper |
|||
|
Insulation |
Material |
PVC |
||
|
Min. Average Thickness |
0.762mm |
|||
|
Min. Thickness at any point |
1.0mm |
|||
|
Diameter |
2.8±0.10mm |
|||
|
Identification |
Blue, Brown, Yellow, Green, White, Black, Red |
|||
|
Core Assembly |
Core Twist |
Single Core |
||
|
Filler |
NA |
|||
|
Assembly Pair |
NA |
|||
|
Taping |
Mylar Foil |
NA |
||
|
Shielded |
A1 – Mylar Foil |
NA |
||
|
Drain |
Material |
NA |
||
|
Construction |
NA |
|||
|
Jacket |
Material |
PVC |
||
|
Min Average Thickness |
0.90mm |
|||
|
Min. Thickness at any point |
0.67mm |
|||
|
Overall Diameter (Approx) |
8.5±0.20 |
|||
|
Color |
Any Color |
|||
|
4 |
Electrical & Physical Properties |
|||
|
Item |
Specification |
|||
|
Rating Voltage |
600V |
|||
|
Conductor Resistance |
6.64Ω/kft 20°c Max |
|||
|
In case of dispute, Conductor resistance shall be the referee method |
||||
|
Insulation Resistance |
0.010MΩ/Km 70°c Min |
|||
|
Dielectric Strength |
AC 2.0KV/5 min No Break |
|||
|
Insulation |
Unaged |
Tensile Strength |
10N/mm² |
|
|
Elongation |
150% Min |
|||
|
Aged |
Tensile Strength |
Min 10N Unaged±20%(85±2°cx240hrs) |
||
|
Elongation |
Min 150% Unaged±20%(85±2°cx240hrs) |
|||
|
Loss of mass Test |
2.0mg/cm² (max) |
|||
|
Jacket |
Unaged |
Tensile Strength |
10N/mm² |
|
|
Elongation |
150% Min |
|||
|
Aged |
Tensile Strength |
Min 10N Unaged±20%(85±2°cx240hrs) |
||
|
Elongation |
Min 150% Unaged±20%(85±2°cx240hrs) |
|||
|
Loss of mass Test |
2.0mg/cm² (max) |
|||
|
Deformation Test |
150mm, 70±2°c x 1hr≤50% |
|||
|
Cold Bend Test |
-15±2°c x 4hr No Crack |
|||
|
Heat Shock Test |
150±2°c x 1hr No Crack |
|||
|
Electric Properties |
|
|
Item |
Specification |
|
Specified voltage and temperature & standard |
UL/CSA : 105°c, 600Vac, 750Vdc, ROHS / RECH |
|
Spark Test |
The insulation must be withstand 5KV high-tension current |
|
Insulation Potengial Strength |
2000V/Min(for water’s environment |
|
Minimum Insulation Resistance |
20°c, DC500V 15MΩ-KM Above |
|
Physical Properties |
|||
|
Based on standard of flammability material testing |
According for UL Subj.758 spec/According for CSA spec |
|
|
|
Before of aging test |
Insulation tensile strength test kgf/mm2 |
1500 psi above |
|
|
Insulation elongation test rate % |
100% above |
|
|
|
After of aging test |
Insulation tensile remnant rate % |
This amount must be above 70% after heat ageing (136°c,168hrs) |
|
|
Insulation elogates remnant rate % |
This amount must be above 65% after heat aging (136°c,168hrs) |
|
|
|
Heating Distortion Test |
The insulation face must be no cracked, high temperature at 120°c for 1 hour |
|
|
|
Thermo Shock Test |
The insulation face must be no cracked, high temperature at 120°c for 1 hour and bent, to withstand 1,000V for 1 Min |
|
|
|
Cold Bending Test |
The insulation face must be no cracked, cooled at -40°c for 3 hour and bent to withstand 1000V for 1 Min |
|
|
|
Oil Resistance |
Immersed in oil at 80°c for 4 hrs and bent to withstand 1000V for 1 Min |
|
|
Hot sale products
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client’s information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client’s requirement.
UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire
Contact Us By Follow Information
Sales Manager: Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No:+86 15053169342
Tel:+86-531-88698938 Fax:+86-531-88662923
Web:luxingcable.en. / luxingcable.en.
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,China
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,China
We are China UL 1 Core PVC Insulated Electric Wire Electrical Wire Cable 600V Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 1 Core Electrical Cable Products
Popular 1 Core Electrical Wire Products
Popular Electrical Wire Products
1.5mm Copper Wire Cable Price BV/Bvr Housing Electrical Wire and Cable
Manufacturer Directly Price En50618 Standard Solar Cable H1z2z2-K 100m Roll
Thhn/Thwn Single Core Copper Conductor Electric Cable Wire
H07V-U BV Solid Wire Cable Bare Copper Electric Wire
0.6/1kv Copper Wire Conductor PVC Insulation PVC Sheath Power Cable
Popular luxingcable Products
2 Core Twisted Pair 300 300V Rvvp Flexible Cable Shield Wire
Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750 V
5 Core Copper Conductor 25mm2 Electrical Power Cable
Bare Copper Wire 99.9% Pure Copper
Iecgbbsul 4 Core 25mm XLPE Insulated Steel Wire Armored Power Cable
Tags: 1 Core Electrical Cable, 1 Core Electrical Wire, Electrical Wire, luxingcable