600/1000V IEC Standard PVC Insulated Power Cable
600/1000V IEC Standard PVC Insulated Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
600/1000V IEC Standard PVC Insulated Power Cable
1.Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors,
in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants,
where there is no risk of mechanical damage.
2.Construction
–Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy,
or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
–Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
–Colour Code
Colour Code (1)
| 1 Core | Red or Black |
| 2 Cores | Red, Black |
| 3 Cores | Red, Yellow, Blue |
| 4 Cores | Red, Yellow, Blue, Black |
| 5 Cores | Red, Yellow, Blue, Black, Green |
| Above 5 Cores | Black Cores with White numerals |
Colour Code (2)
| 1 Core | Brown or Blue |
| 2 Cores | Brown, Blue |
| 3 Cores | Brown, Black, Grey |
| 4 Cores | Blue, Brown, Black, Grey |
| 5 Cores | Green/Yellow, Blue, Brown, Black, Grey |
| Above 5 Cores | Black Cores with White numerals |
Other colours can be manufactured upon request.
–Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores,
a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled.
A suitable binder is permitted before application of an extruded inner covering.
The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the
insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
–Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1,
or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
–Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8,
Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
–Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22,
IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
3.Parameters
Single core(unarmoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm |
| 1×4 | 2.3 | 1 | 1.4 | 7.1 |
| 1×6 | 2.8 | 1 | 1.4 | 7.6 |
| 1×10 | 3.6 | 1 | 1.4 | 8.4 |
| 1×16 | 4.5 | 1 | 1.4 | 9.3 |
| 1×25 | 5.6 | 1.2 | 1.4 | 10.8 |
| 1×35 | 6.7 | 1.2 | 1.4 | 11.9 |
| 1×50 | 8 | 1.4 | 1.4 | 13.6 |
| 1×70 | 9.4 | 1.4 | 1.4 | 15.1 |
| 1×95 | 11 | 1.6 | 1.5 | 17.2 |
| 1×120 | 12.4 | 1.6 | 1.5 | 18.7 |
| 1×150 | 13.8 | 1.8 | 1.6 | 20.6 |
| 1×185 | 15.3 | 2 | 1.7 | 22.7 |
| 1×240 | 17.5 | 2.2 | 1.8 | 25.4 |
| 1×300 | 19.5 | 2.4 | 1.9 | 28.0 |
| 1×400 | 22.6 | 2.6 | 2.0 | 31.7 |
| 1×500 | 25.2 | 2.8 | 2.1 | 35.0 |
| 1×630 | 28.3 | 2.8 | 2.2 | 38.3 |
Two cores(unarmoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.8 | 1.8 | 9.6 |
| 2×2.5 | 1.8 | 0.8 | 1.8 | 10.4 |
| 2×4 | 2.3 | 1 | 1.8 | 12.2 |
| 2×6 | 2.8 | 1 | 1.8 | 13.2 |
| 2×10 | 3.6 | 1 | 1.8 | 14.8 |
| 2×16 | 4.5 | 1 | 1.8 | 16.6 |
| 2×25 | 5.6 | 1.2 | 1.8 | 19.6 |
| 2×35 | 6.7 | 1.2 | 1.8 | 21.8 |
| 2×50 | 8 | 1.4 | 1.8 | 25.2 |
| 2×70 | 9.4 | 1.4 | 1.9 | 28.1 |
| 2×95 | 11 | 1.6 | 2.0 | 32.4 |
| 2×120 | 12.4 | 1.6 | 2.1 | 35.4 |
| 2×150 | 13.8 | 1.8 | 2.2 | 39.2 |
| 2×185 | 15.3 | 2 | 2.4 | 43.3 |
| 2×240 | 17.5 | 2.2 | 2.5 | 48.9 |
| 2×300 | 19.5 | 2.4 | 2.7 | 54.0 |
| 2×400 | 22.6 | 2.6 | 2.9 | 61.5 |
Three cores(unarmoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | |
| mm^2 | mm | mm | mm | mm | |
| 3×1.5 | 1.4 | 0.8 | 1.8 | 10.1 | |
| 3×2.5 | 1.8 | 0.8 | 1.8 | 10.9 | |
| 3×4 | 2.3 | 1 | 1.8 | 12.9 | |
| 3×6 | 2.8 | 1 | 1.8 | 13.9 | |
| 3×10 | 3.6 | 1 | 1.8 | 15.7 | |
| 3×16 | 4.5 | 1 | 1.8 | 17.6 | |
| 3×25 | 5.6 | 1.2 | 1.8 | 20.8 | |
| 3×35 | 6.7 | 1.2 | 1.8 | 23.2 | |
| 3×50 | 8 | 1.4 | 1.8 | 26.9 | |
| 3×70 | 9.4 | 1.4 | 1.9 | 30.1 | |
| 3×95 | 11 | 1.6 | 2.1 | 34.7 | |
| 3×120 | 12.4 | 1.6 | 2.2 | 38.0 | |
| 3×150 | 13.8 | 1.8 | 2.3 | 42.1 | |
| 3×185 | 15.3 | 2 | 2.5 | 46.5 | |
| 3×240 | 17.5 | 2.2 | 2.7 | 52.5 | |
| 3×300 | 19.5 | 2.4 | 2.8 | 58.0 | |
| 3×400 | 22.6 | 2.6 | 3.1 | 66.1 | |
Three cores+1(unarmoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
| mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 1 | 1 | 1.8 | 19.0 |
| 3x 25/16 | 5.6 | 4.5 | 1.2 | 1 | 1.8 | 22.6 |
| 3x 35/16 | 6.7 | 4.5 | 1.2 | 1 | 1.8 | 25.3 |
| 3x 50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1.9 | 29.6 |
| 3x 70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 2.0 | 33.2 |
| 3x 95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 2.2 | 38.4 |
| 3×120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 2.3 | 42.0 |
| 3×150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 2.5 | 46.6 |
| 3×185/95 | 15.3 | 11.0 | 2 | 1.6 | 2.6 | 51.6 |
| 3×240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 2.9 | 58.3 |
| 3×300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 3.1 | 64.5 |
| 3×400/185 | 22.6 | 15.3 | 2.6 | 2 | 3.3 | 73 |
Four cores(unarmored)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.8 | 1.8 | 10.8 |
| 4×2.5 | 1.8 | 0.8 | 1.8 | 11.8 |
| 4×4 | 2.3 | 1 | 1.8 | 14.0 |
| 4×6 | 2.8 | 1 | 1.8 | 15.2 |
| 4×10 | 3.6 | 1 | 1.8 | 17.1 |
| 4×16 | 4.5 | 1 | 1.8 | 19.3 |
| 4×25 | 5.6 | 1.2 | 1.8 | 22.9 |
| 4×35 | 6.7 | 1.2 | 1.8 | 25.6 |
| 4×50 | 8 | 1.4 | 1.9 | 29.9 |
| 4×70 | 9.4 | 1.4 | 2.0 | 33.5 |
| 4×95 | 11 | 1.6 | 2.2 | 38.7 |
| 4×120 | 12.4 | 1.6 | 2.3 | 42.3 |
| 4×150 | 13.8 | 1.8 | 2.5 | 46.9 |
| 4×185 | 15.3 | 2 | 2.6 | 51.9 |
| 4×240 | 17.5 | 2.2 | 2.9 | 58.6 |
| 4×300 | 19.5 | 2.4 | 3.1 | 64.8 |
| 4×400 | 22.6 | 2.6 | 3.3 | 73.8 |
Multi-cores(unarmoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm |
| 5×1.5 | 1.4 | 0.8 | 1.8 | 11.7 |
| 7×1.5 | 1.4 | 0.8 | 1.8 | 12.6 |
| 10×1.5 | 1.4 | 0.8 | 1.8 | 15.6 |
| 12×1.5 | 1.4 | 0.8 | 1.8 | 16.1 |
| 14×1.5 | 1.4 | 0.8 | 1.8 | 16.8 |
| 19×1.5 | 1.4 | 0.8 | 1.8 | 18.6 |
| 21×1.5 | 1.4 | 0.8 | 1.8 | 19.5 |
| 24×1.5 | 1.4 | 0.8 | 1.8 | 21.6 |
| 30×1.5 | 1.4 | 0.8 | 1.8 | 22.8 |
| 40×1.5 | 1.4 | 0.8 | 1.8 | 27.7 |
| 48×1.5 | 1.4 | 0.8 | 1.9 | 28.2 |
| 61×1.5 | 1.4 | 0.8 | 1.9 | 30.9 |
| 5×2.5 | 1.8 | 0.8 | 1.8 | 12.8 |
| 7×2.5 | 1.8 | 0.8 | 1.8 | 13.8 |
| 10×2.5 | 1.8 | 0.8 | 1.8 | 17.2 |
| 12×2.5 | 1.8 | 0.8 | 1.8 | 17.7 |
| 14×2.5 | 1.8 | 0.8 | 1.8 | 18.6 |
| 19×2.5 | 1.8 | 0.8 | 1.8 | 20.6 |
| 21×2.5 | 1.8 | 0.8 | 1.8 | 21.6 |
| 24×2.5 | 1.8 | 0.8 | 1.8 | 24.0 |
| 30×2.5 | 1.8 | 0.8 | 1.8 | 25.4 |
| 40×2.5 | 1.8 | 0.8 | 2.0 | 31.1 |
| 48×2.5 | 1.8 | 0.8 | 2.0 | 31.7 |
| 61×2.5 | 1.8 | 0.8 | 2.1 | 34.7 |
Single core( aluminum wire armoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 1 | 1.0 | 0.8 | 1.8 | 11.5 |
| 1×6 | 2.8 | 1 | 1.0 | 0.8 | 1.8 | 12.0 |
| 1×10 | 3.6 | 1 | 1.0 | 0.8 | 1.8 | 12.8 |
| 1×16 | 4.5 | 1 | 1.0 | 0.8 | 1.8 | 13.7 |
| 1×25 | 5.6 | 1.2 | 1.0 | 0.8 | 1.8 | 15.2 |
| 1×35 | 6.7 | 1.2 | 1.0 | 1.25 | 1.8 | 17.2 |
| 1×50 | 8.0 | 1.4 | 1.0 | 1.25 | 1.8 | 18.9 |
| 1×70 | 9.4 | 1.4 | 1.0 | 1.25 | 1.8 | 20.3 |
| 1×95 | 11.0 | 1.6 | 1.0 | 1.6 | 1.8 | 23.0 |
| 1×120 | 12.4 | 1.6 | 1.0 | 1.6 | 1.8 | 24.4 |
| 1×150 | 13.8 | 1.8 | 1.0 | 1.6 | 1.8 | 26.2 |
| 1×185 | 15.3 | 2 | 1.0 | 1.6 | 1.9 | 28.2 |
| 1×240 | 17.5 | 2.2 | 1.0 | 1.6 | 1.9 | 31.0 |
| 1×300 | 19.5 | 2.4 | 1.0 | 2.0 | 2.1 | 34.4 |
| 1×400 | 22.6 | 2.6 | 1.2 | 2.0 | 2.2 | 38.6 |
| 1×500 | 25.2 | 2.8 | 1.2 | 2.0 | 2.3 | 41.8 |
| 1×630 | 28.3 | 2.8 | 1.2 | 2.5 | 2.4 | 46.2 |
Two cores(Galvanized steel wire armoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm | mm | mm |
| 2×2.5 | 1.8 | 0.8 | 1.0 | 0.8 | 1.8 | 14.0 |
| 2×4 | 2.3 | 1 | 1.0 | 1.25 | 1.8 | 16.7 |
| 2×6 | 2.8 | 1 | 1.0 | 1.25 | 1.8 | 17.7 |
| 2×10 | 3.6 | 1 | 1.0 | 1.25 | 1.8 | 19.3 |
| 2×16 | 4.5 | 1 | 1.0 | 1.25 | 1.8 | 21.1 |
| 2×25 | 5.6 | 1.2 | 1.0 | 1.6 | 1.8 | 24.8 |
| 2×35 | 6.7 | 1.2 | 1.0 | 1.6 | 1.8 | 27.0 |
| 2×50 | 8 | 1.4 | 1.0 | 1.6 | 1.9 | 30.7 |
| 2×70 | 9.4 | 1.4 | 1.0 | 2.0 | 2.1 | 34.5 |
| 2×95 | 11 | 1.6 | 1.2 | 2.0 | 2.2 | 39.2 |
| 2×120 | 12.4 | 1.6 | 1.2 | 2.0 | 2.3 | 42.2 |
| 2×150 | 13.8 | 1.8 | 1.2 | 2.5 | 2.5 | 47.2 |
| 2×185 | 15.3 | 2 | 1.4 | 2.5 | 2.6 | 51.6 |
| 2×240 | 17.5 | 2.2 | 1.4 | 2.5 | 2.8 | 57.2 |
| 2×300 | 19.5 | 2.4 | 1.6 | 2.5 | 3.0 | 62.8 |
| 2×400 | 22.6 | 2.6 | 1.6 | 2.5 | 3.2 | 70.3 |
Thr cores(Galvanized steel wire armoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm | mm | mm |
| 3×2.5 | 1.8 | 0.8 | 1.0 | 0.8 | 1.8 | 14.5 |
| 3×4 | 2.3 | 1 | 1.0 | 1.25 | 1.8 | 17.4 |
| 3×6 | 2.8 | 1 | 1.0 | 1.25 | 1.8 | 18.4 |
| 3×10 | 3.6 | 1 | 1.0 | 1.25 | 1.8 | 20.2 |
| 3×16 | 4.5 | 1 | 1.0 | 1.6 | 1.8 | 22.8 |
| 3×25 | 5.6 | 1.2 | 1.0 | 1.6 | 1.8 | 26.0 |
| 3×35 | 6.7 | 1.2 | 1.0 | 1.6 | 1.9 | 28.5 |
| 3×50 | 8.0 | 1.4 | 1.0 | 2 | 2.0 | 33.3 |
| 3×70 | 9.4 | 1.4 | 1.2 | 2 | 2.1 | 37.0 |
| 3×95 | 11.0 | 1.6 | 1.2 | 2 | 2.3 | 41.6 |
| 3×120 | 12.4 | 1.6 | 1.2 | 2.5 | 2.4 | 45.9 |
| 3×150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.6 | 50.4 |
| 3×185 | 15.3 | 2 | 1.4 | 2.5 | 2.7 | 54.8 |
| 3×240 | 17.5 | 2.2 | 1.5 | 2.5 | 2.9 | 61.2 |
| 3×300 | 19.5 | 2.4 | 1.6 | 2.5 | 3.1 | 66.8 |
| 3×400 | 22.6 | 2.8 | 1.6 | 3.15 | 3.4 | 76.7 |
| 3×500 | 25.2 | 2.8 | 1.8 | 3.15 | 3.7 | 83.6 |
Three cores+1(Galvanized steel wire armoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) | ||
| mm^2 | mm | mm | mm | mm | mm | mm | mm | mm |
| 3×10/6 | 3.6 | 2.8 | 1 | 1 | 1 | 1.25 | 1.8 | 21.9 |
| 3×16/10 | 4.5 | 3.6 | 1 | 1 | 1 | 1.6 | 1.8 | 24.2 |
| 3×25/16 | 5.6 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.8 | 27.9 |
| 3×35/16 | 6.7 | 4.5 | 1.2 | 1 | 1 | 1.6 | 1.9 | 30.8 |
| 3×50/25 | 8.0 | 5.6 | 1.4 | 1.2 | 1 | 2.0 | 2.0 | 36.4 |
| 3×70/35 | 9.4 | 6.7 | 1.4 | 1.2 | 1.2 | 2.0 | 2.1 | 40.1 |
| 3×95/50 | 11.0 | 8.0 | 1.6 | 1.4 | 1.2 | 2.5 | 2.3 | 46.3 |
| 3×120/70 | 12.4 | 9.4 | 1.6 | 1.4 | 1.4 | 2.5 | 2.4 | 50.3 |
| 3×150/70 | 13.8 | 9.4 | 1.8 | 1.4 | 1.4 | 2.5 | 2.6 | 55.0 |
| 3×185/95 | 15.3 | 11.0 | 2 | 1.6 | 1.4 | 2.5 | 2.7 | 60.3 |
| 3×240/120 | 17.5 | 12.4 | 2.2 | 1.6 | 1.6 | 2.5 | 2.9 | 67.0 |
| 3×300/150 | 19.5 | 13.8 | 2.4 | 1.8 | 1.6 | 3.15 | 3.1 | 74.6 |
| 3×400/185 | 22.6 | 15.3 | 2.6 | 2 | 1.8 | 3.15 | 3.4 | 84.1 |
| 3×500/240 | 25.2 | 17.5 | 2.8 | 2.2 | 2 | 3.15 | 3.7 | 91 |
Four cores(Galvanized steel wire armoured)
| Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation thickness | Nominal Inner Covering thickness | Nominal Steel Wire dia. | Nominal Sheath thickness | Overall Diameter (Approx.) |
| mm^2 | mm | mm | mm | mm | mm | mm |
| 4×4 | 2.3 | 1 | 1 | 1.25 | 1.8 | 18.5 |
| 4×6 | 2.8 | 1 | 1 | 1.25 | 1.8 | 19.7 |
| 4×10 | 3.6 | 1 | 1 | 1.25 | 1.8 | 22.3 |
| 4×16 | 4.5 | 1 | 1 | 1.6 | 1.8 | 24.5 |
| 4×25 | 5.6 | 1.2 | 1 | 1.6 | 1.9 | 28.2 |
| 4×35 | 6.7 | 1.2 | 1 | 1.6 | 2.0 | 31.1 |
| 4×50 | 8.0 | 1.4 | 1 | 2.0 | 2.1 | 36.7 |
| 4×70 | 9.4 | 1.4 | 1.2 | 2.0 | 2.3 | 40.4 |
| 4×95 | 11.0 | 1.6 | 1.2 | 2.5 | 2.5 | 46.6 |
| 4×120 | 12.4 | 1.6 | 1.4 | 2.5 | 2.6 | 50.6 |
| 4×150 | 13.8 | 1.8 | 1.4 | 2.5 | 2.7 | 55.3 |
| 4×185 | 15.3 | 2 | 1.4 | 2.5 | 2.9 | 60.6 |
| 4×240 | 17.5 | 2.2 | 1.6 | 2.5 | 3.1 | 67.3 |
| 4×300 | 19.5 | 2.4 | 1.6 | 3.15 | 3.4 | 74.9 |
| 4×400 | 22.6 | 2.6 | 1.8 | 3.15 | 3.7 | 84.4 |
| 4×500 | 25.2 | 2.8 | 2 | 3.15 | 3.9 | 92.1 |
We are China 600/1000V IEC Standard PVC Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cu PVC PVC Cable Products
ABC Cable for Power Transmitting
Copper Conductor Wire Copper Cable Prices Submarine Cable 2.5mm2
Vct Cable, 600V Vinyl Cabtire Power Cable, Luxing Cable Factory
Vct Cable Specification 450/750V IEC60227 Cu/PVC/PVC Cable
Vct Cable, Flexible Cable, Vct Cable Suppliers and Manufacturers
PVC Insulated Sheathed Electrical Cable Wire 600/1000V Cu PVC PVC
Popular luxingcable Products
Zr-Yjv IEC Standard 4X95mm2 Power Cable
16mm Aluminium XLPE Cable/Aluminum Cable XLPE/Aluminum Cable 240mm2
Supplying Electric Wire Cable 35mm2 AWG Cable From New Luxing Factory
Copper Core Cable Electrical Wire Electrical Cables and Wires 1.5mm 2.5mm 4mm 6mm 10mm 16mm 25mm
Popular Power Cable Products
High Voltage Steel Armoured XLPE/PVC Insulated Electric Wire Power Cable
Yjv/Yjy PVC Insulated Electrical Power Cable
Yjlv Low Voltage 0.6/1kv XLPE PVC Insulation Power Cable
Primary Ud Cable, 15 Kv, Al/Epr/Neutral/PVC (AEIC CS 8/ICEA S-94-649)
Popular PVC Insulated Power Cable Products
Aluminum Core PVC Insulation Underground Power Cable
Copper Conductior PVC Silicone Rubber Insulated Wire Electric Power Cable Fire Alarm Cable
Bare Conductor Cable Wire Electrical Aluminum Clad Steel Core
Low Voltage PVC Insulated Armoured Flexible Electric
Tags: Cu PVC PVC Cable, luxingcable, Power Cable, PVC Insulated Power Cable