Wholesale Factory Direct Sales 500mcm XLPE Insulated Copper Power Cable
Wholesale Factory Direct Sales 500mcm XLPE Insulated Copper Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Wholesale Factory Direct Sales 500MCm XLPE Insulated Copper Power Cable
TOP TEN CABLE MANUFACTURER IN CHINA
LARGEST CABLE MANUFACTUER IN NORTH CHINAANNUAL EXPORT VOLUME EXCEED 200MILLION USD
WITH UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD’S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS
WITH TUV TYPE TESTING REPORTWIDE PRODUCTS RANGE
ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONSCNAS APPROVAL LABROTARY
Product Description Of 500MCm XLPE Insulated Copper Power Cable
Product standard:
GB/T12706.1-2008
Application:
This product is suitable for power transmission and distribution line of rated voltage (U0/U) 0.6/1.0KV line.
Technical Parameter:
When the cable is running normally, the Maximum temperature of conductor is 90ºC; and is 250 ºC when the short circuit (Max. last 5s) happens.
The ambient temperature of installation shall not lower than 0 degrees.
Minimum bending radius is 12 D ("D" refers to cable diameter)
Single Core Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 1*1.5 | 0.7 | 1.5 | 6 | 53 | 53 | ≤12.1 | ≤12.1 | 3.5 | 26 | 26 | 33 | 32 |
| 1*2.5 | 0.7 | 1.5 | 6 | 68 | ≤7.41 | 3.5 | 34 | 43 | ||||
| 1*4 | 0.7 | 1.5 | 7 | 87 | 64 | ≤4.61 | ≤7.41 | 3.5 | 44 | 35 | 56 | 42 |
| 1*6 | 0.7 | 1.5 | 7 | 110 | 73 | ≤3.08 | ≤4.61 | 3.5 | 56 | 45 | 70 | 54 |
Two Cores Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 2*2.5 | 0.7 | 1.8 | 11.8 | 151 | 118 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
| 2*4 | 0.7 | 1.8 | 12.7 | 198 | 146 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 2*6 | 0.7 | 1.8 | 13.7 | 250 | 173 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 2*10 | 0.7 | 1.8 | 16.3 | 374 | 245 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 3×1.5 | 0.7 | 1.5 | 10 | 145 | – | ≤12.1 | – | 3.5 | 20 | – | 27 | – |
| 3×1.6 | 0.7 | 1.5 | 11 | 185 | 140 | ≤7.41 | ≤12.1 | 3.5 | 26 | 20 | 35 | 27 |
| 3×4 | 0.7 | 1.5 | 12 | 250 | 175 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 3×6 | 0.7 | 1.5 | 13 | 320 | 210 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 3×10 | 0.7 | 1.5 | 15 | 450 | 260 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 4×4 | 0.7 | 1.5 | 13 | 253 | 155 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 4×6 | 0.7 | 1.5 | 14 | 337 | 184 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 4×10 | 0.7 | 1.5 | 16 | 501 | 258 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+One Core Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 3×4+1×2.5 | 0.7 | 1.5 | 13 | 236 | 147 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 3×6+1×4 | 0.7 | 1.5 | 14 | 316 | 187 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 3×10+1×6 | 0.7 | 1.5 | 16 | 461 | 234 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Three Cores+Two Cores Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 3×4+2×2.5 | 0.7 | 1.5 | 13.9 | 309 | 202 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 3×6+2×4 | 0.7 | 1.5 | 15.3 | 413 | 219 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 3×10+2×6 | 0.7 | 1.5 | 18.2 | 603 | 338 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Four Cores+One Core Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 4×4+1×2.5 | 0.7 | 1.5 | 14.5 | 331 | 214 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 4×6+1×4 | 0.7 | 1.5 | 15.9 | 435 | 259 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 4×10+1×6 | 0.7 | 1.5 | 18.9 | 649 | 359 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Five Cores Cable
| Nominal cross section | Nominal Thickness of Insulation | Nominal thickness of Sheath | Approx. Overall Diameter of Cable | Approximate weight of cable | Conductor DC resistance | Test voltage | Cable Current | |||||
| In the air | Buried in soil | |||||||||||
| Cu | AL | Cu | AL | Cu | AL | Cu | AL | |||||
| mm² | mm | mm | mm | Kg/km | Kg/km | Ω/km | Ω/km | kv/5min | A | A | A | A |
| 5×4 | 0.7 | 1.5 | 14.5 | 349 | 223 | ≤4.61 | ≤7.41 | 3.5 | 34 | 27 | 45 | 36 |
| 5×6 | 0.7 | 1.5 | 15.8 | 460 | 271 | ≤3.08 | ≤4.61 | 3.5 | 43 | 35 | 57 | 46 |
| 5×10 | 0.7 | 1.5 | 19.3 | 699 | 384 | ≤1.83 | ≤3.08 | 3.5 | 60 | 47 | 77 | 59 |
Related Product Picture
Exhibition:
Certificates
Packaging & Shipping
All cable For exporting are well packed and protected by wooden drum or Wood and Steel Drum.The packing material is depended on the weight and size of cable.The good information, manufacture information, and the client’s information is firmly printed on each size of drum.
After the well packed cable drums sent to Sea Port, they are loaded into 20 FT container or 40 FT container. All cable drum are firmly fixed by safety belt to make sure, no movement during the sea freight.
The size of the container is chosed according to weight of total loaded goods or as per the client’s requirement.
Wholesale Factory Direct Sales 500MCm XLPE Insulated Copper Power Cable
Contact Us By Follow Information
Sales Manager: Leslie Shaw
Shandong New Luxing Cable Co.,Ltd
Phone No:+86 15053169342
Tel:+86-531-88698938 Fax:+86-531-88662923
Web:luxingcable.en. / luxingcable.en.
Factory Add:West Side, Southern Huaxing Road, Linyi Town, Dezhou city,Shandong Province,China
Office Add:Room D901, Binhe Business Center, Tiaoqian district, Jinan city, Shandong Province,China
We are China Wholesale Factory Direct Sales 500mcm XLPE Insulated Copper Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 500mcm Cable Products
35kv 100% or 133% Epr Insulated Single Core 500mcm Mv Cable with UL1072
0.6/1kv Ttu 500mcm Copper XLPE Insulated Power Cable for Underground
500mcm Useb CSA cUL 600V Electric Cable Power Cable
Popular 500mcm Power Cable Products
500mcm Mv Urd Medium Voltage Used XLPE Insulated Underground Copper Power Cable
Popular 500mcm XLPE Insulated Copper Power Cable Products
Popular luxingcable Products
400 Sq mm Cable/400mm Power Cable/400 Kv Cable
Rough Surface 2 Conductor Super Flat Electrical Wires 60mm Width Flat Cable Patented Technology Wire
1core - 5core XLPE Insulation Al Power Cable
H05V-U Solid Single Core 1.5mm Copper Conductor PVC Electric Wire
Tags: 500mcm Cable, 500mcm Power Cable, 500mcm XLPE Insulated Copper Power Cable, luxingcable
