11kv XLPE Insulated Copper Core PVC Sheathed Power Cable, Electric Cable
11kv XLPE Insulated Copper Core PVC Sheathed Power Cable, Electric Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
6.0 |
2.5 |
0.12 |
1.5 |
17.6 |
0.34 |
0.49 |
1.2000 |
0.7270 |
35 |
7.0 |
2.5 |
0.12 |
1.5 |
18.5 |
0.39 |
0.60 |
0.8680 |
0.5240 |
50 |
8.3 |
2.5 |
0.12 |
1.6 |
20.0 |
0.46 |
0.74 |
0.6410 |
0.3870 |
70 |
9.7 |
2.5 |
0.12 |
1.6 |
21.5 |
0.55 |
0.96 |
0.4430 |
0.2680 |
95 |
11.3 |
2.5 |
0.12 |
1.7 |
23.3 |
0.66 |
1.23 |
0.3200 |
0.1930 |
120 |
13 |
2.5 |
0.12 |
1.7 |
24.8 |
0.77 |
1.48 |
0.2530 |
0.1530 |
150 |
14.6 |
2.5 |
0.12 |
1.8 |
26.4 |
0.87 |
1.77 |
0.2060 |
0.1240 |
185 |
15.9 |
2.5 |
0.12 |
1.8 |
28.1 |
1.01 |
2.13 |
0.1640 |
0.0991 |
240 |
18.3 |
2.6 |
0.12 |
1.9 |
30.9 |
1.23 |
2.71 |
0.1250 |
0.0754 |
300 |
20.4 |
2.8 |
0.12 |
2.0 |
33.6 |
1.48 |
3.32 |
0.1000 |
0.0601 |
400 |
23.2 |
3.0 |
0.12 |
2.1 |
37.0 |
1.81 |
4.16 |
0.0778 |
0.0470 |
500 |
26.4 |
3.2 |
0.12 |
2.2 |
41.1 |
2.24 |
5.27 |
0.0605 |
0.0366 |
630 |
30.1 |
3.2 |
0.12 |
2.3 |
45.0 |
2.73 |
6.62 |
0.0469 |
0.0283 |
2)6/10(12)kV,6.35/11(12)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.12 |
1.5 |
19.4 |
0.40 |
0.55 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.12 |
1.6 |
20.5 |
0.45 |
0.66 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.12 |
1.6 |
21.8 |
0.52 |
0.80 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.12 |
1.7 |
23.5 |
0.62 |
1.03 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.12 |
1.7 |
25.1 |
0.73 |
1.30 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.12 |
1.8 |
26.8 |
0.85 |
1.56 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.12 |
1.8 |
28.2 |
0.95 |
1.85 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.12 |
1.9 |
30.1 |
1.10 |
2.22 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.12 |
2.0 |
32.7 |
1.33 |
2.80 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.12 |
2.0 |
34.8 |
1.54 |
3.39 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.12 |
2.2 |
38.0 |
1.87 |
4.22 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.12 |
2.2 |
41.5 |
2.26 |
5.29 |
0.0605 |
0.0366 |
|
630 |
30.1 |
3.4 |
0.12 |
2.4 |
45.6 |
2.78 |
6.67 |
0.0469 |
0.0283 |
3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
4.5 |
0.12 |
1.6 |
21.8 |
0.48 |
0.63 |
1.2000 |
0.7270 |
|
35 |
6.9 |
4.5 |
0.12 |
1.7 |
22.9 |
0.54 |
0.75 |
0.8680 |
0.5240 |
|
50 |
8.2 |
4.5 |
0.12 |
1.7 |
24.2 |
0.61 |
0.89 |
0.6410 |
0.3870 |
|
70 |
9.7 |
4.5 |
0.12 |
1.8 |
25.9 |
0.72 |
1.13 |
0.4430 |
0.2680 |
|
95 |
11.3 |
4.5 |
0.12 |
1.8 |
27.5 |
0.84 |
1.40 |
0.3200 |
0.1930 |
|
120 |
12.8 |
4.5 |
0.12 |
1.9 |
29.2 |
0.96 |
1.67 |
0.2530 |
0.1530 |
|
150 |
14.2 |
4.5 |
0.12 |
1.9 |
30.6 |
1.06 |
1.96 |
0.2060 |
0.1240 |
|
185 |
15.9 |
4.5 |
0.12 |
2.0 |
32.5 |
1.22 |
2.34 |
0.1640 |
0.0991 |
|
240 |
18.3 |
4.5 |
0.12 |
2.1 |
35.1 |
1.46 |
2.93 |
0.1250 |
0.0754 |
|
300 |
20.4 |
4.5 |
0.12 |
2.1 |
37.2 |
1.68 |
3.52 |
0.1000 |
0.0601 |
|
400 |
23.2 |
4.5 |
0.12 |
2.2 |
40.2 |
2.00 |
4.35 |
0.0778 |
0.0470 |
|
500 |
26.4 |
4.5 |
0.12 |
2.3 |
43.9 |
2.43 |
5.45 |
0.0605 |
0.0366 |
|
630 |
30.1 |
4.5 |
0.12 |
2.4 |
47.8 |
2.93 |
6.83 |
0.0469 |
0.0283 |
4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
|
|
|
|
|
|
|
|
|
35 |
6.9 |
5.5 |
0.12 |
1.7 |
24.9 |
0.62 |
0.83 |
0.8680 |
0.5240 |
50 |
8.2 |
5.5 |
0.12 |
1.8 |
26.4 |
0.70 |
0.98 |
0.6410 |
0.3870 |
70 |
9.7 |
5.5 |
0.12 |
1.8 |
27.9 |
0.80 |
1.21 |
0.4430 |
0.2680 |
95 |
11.3 |
5.5 |
0.12 |
1.9 |
29.7 |
0.94 |
1.50 |
0.3200 |
0.1930 |
120 |
12.8 |
5.5 |
0.12 |
1.9 |
31.2 |
1.05 |
1.77 |
0.2530 |
0.1530 |
150 |
14.2 |
5.5 |
0.12 |
2.0 |
32.8 |
1.17 |
2.07 |
0.2060 |
0.1240 |
185 |
15.9 |
5.5 |
0.12 |
2.0 |
34.5 |
1.33 |
2.45 |
0.1640 |
0.0991 |
240 |
18.3 |
5.5 |
0.12 |
2.1 |
37.1 |
1.57 |
3.04 |
0.1250 |
0.0754 |
300 |
20.4 |
5.5 |
0.12 |
2.2 |
39.4 |
1.81 |
3.66 |
0.1000 |
0.0601 |
400 |
23.2 |
5.5 |
0.12 |
2.3 |
42.4 |
2.14 |
4.49 |
0.0778 |
0.0470 |
500 |
26.4 |
5.5 |
0.12 |
2.4 |
46.1 |
2.58 |
5.61 |
0.0605 |
0.0366 |
630 |
30.1 |
5.5 |
0.12 |
2.4 |
49.8 |
3.10 |
6.99 |
0.0469 |
0.0283 |
5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
|
|
|
|
|
|
|
|
|
|
35 |
|
|
|
|
|
|
|
|
|
|
50 |
8.2 |
8.0 |
0.12 |
2.0 |
31.8 |
0.95 |
1.23 |
0.6410 |
0.3870 |
|
70 |
9.7 |
8.0 |
0.12 |
2.0 |
33.3 |
1.07 |
1.47 |
0.4430 |
0.2680 |
|
95 |
11.3 |
8.0 |
0.12 |
2.1 |
35.1 |
1.21 |
1.78 |
0.3200 |
0.1930 |
|
120 |
12.8 |
8.0 |
0.12 |
2.1 |
36.6 |
1.34 |
2.05 |
0.2530 |
0.1530 |
|
150 |
14.2 |
8.0 |
0.12 |
2.2 |
38.2 |
1.47 |
2.37 |
0.2060 |
0.1240 |
|
185 |
15.9 |
8.0 |
0.12 |
2.2 |
39.9 |
1.64 |
2.76 |
0.1640 |
0.0991 |
|
240 |
18.3 |
8.0 |
0.12 |
2.3 |
42.5 |
1.90 |
3.37 |
0.1250 |
0.0754 |
|
300 |
20.4 |
8.0 |
0.12 |
2.4 |
44.8 |
2.16 |
4.01 |
0.1000 |
0.0601 |
|
400 |
23.2 |
8.0 |
0.12 |
2.4 |
47.6 |
2.52 |
4.87 |
0.0778 |
0.0470 |
|
500 |
26.4 |
8.0 |
0.12 |
2.5 |
51.3 |
2.98 |
6.01 |
0.0605 |
0.0366 |
|
630 |
30.1 |
8.0 |
0.12 |
2.6 |
55.2 |
3.54 |
7.43 |
0.0469 |
0.0283 |
6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
2.5 |
0.1 |
2.0 |
34.6 |
1.13 |
1.58 |
1.2000 |
0.7270 |
||
35 |
6.9 |
2.5 |
0.1 |
2.1 |
36.8 |
1.29 |
1.92 |
0.8680 |
0.5240 |
||
50 |
8.2 |
2.5 |
0.1 |
2.2 |
39.8 |
1.51 |
2.36 |
0.6410 |
0.3870 |
||
70 |
9.7 |
2.5 |
0.1 |
2.3 |
43.2 |
1.81 |
3.04 |
0.4430 |
0.2680 |
||
95 |
11.3 |
2.5 |
0.1 |
2.4 |
46.9 |
2.17 |
3.87 |
0.3200 |
0.1930 |
||
120 |
12.8 |
2.5 |
0.1 |
2.4 |
50.1 |
2.53 |
4.69 |
0.2530 |
0.1530 |
||
150 |
14.2 |
2.5 |
0.1 |
2.5 |
53.3 |
2.90 |
5.60 |
0.2060 |
0.1240 |
||
185 |
15.9 |
2.5 |
0.1 |
2.6 |
57.2 |
3.40 |
6.77 |
0.1640 |
0.0991 |
||
240 |
18.3 |
2.6 |
0.1 |
2.8 |
63.2 |
4.12 |
8.55 |
0.1250 |
0.0754 |
||
300 |
20.4 |
2.8 |
0.1 |
3.0 |
69.0 |
4.89 |
10.46 |
0.1000 |
0.0601 |
||
400 |
23.2 |
3.0 |
0.1 |
3.4 |
76.7 |
6.10 |
13.18 |
0.0778 |
0.0470 |
||
500 |
26.4 |
3.2 |
0.1 |
3.6 |
85.7 |
8.10 |
16.55 |
0.0605 |
0.0366 |
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
|||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
|
25 |
6.0 |
3.4 |
0.1 |
2.1 |
38.7 |
1.30 |
1.75 |
1.2000 |
0.7270 |
|
35 |
6.9 |
3.4 |
0.1 |
2.2 |
40.9 |
1.47 |
2.22 |
0.8680 |
0.5240 |
|
50 |
8.2 |
3.4 |
0.1 |
2.3 |
43.9 |
1.70 |
2.50 |
0.6410 |
0.3870 |
|
70 |
9.7 |
3.4 |
0.1 |
2.4 |
47.3 |
2.02 |
3.25 |
0.4430 |
0.2680 |
|
95 |
11.3 |
3.4 |
0.1 |
2.5 |
51.0 |
2.42 |
4.12 |
0.3200 |
0.1930 |
|
120 |
12.8 |
3.4 |
0.1 |
2.6 |
54.4 |
2.79 |
4.95 |
0.2530 |
0.1530 |
|
150 |
14.2 |
3.4 |
0.1 |
2.7 |
57.6 |
3.17 |
5.87 |
0.2060 |
0.1240 |
|
185 |
15.9 |
3.4 |
0.1 |
2.8 |
61.5 |
3.69 |
7.06 |
0.1640 |
0.0991 |
|
240 |
18.3 |
3.4 |
0.1 |
2.9 |
66.9 |
4.38 |
8.82 |
0.1250 |
0.0754 |
|
300 |
20.4 |
3.4 |
0.1 |
3.1 |
71.8 |
5.11 |
10.68 |
0.1000 |
0.0601 |
|
400 |
23.2 |
3.4 |
0.1 |
3.3 |
78.3 |
6.24 |
13.32 |
0.0778 |
0.0470 |
|
500 |
26.4 |
3.4 |
0.1 |
3.5 |
86.4 |
7.63 |
16.50 |
0.0605 |
0.0366 |
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
6.0 |
4.5 |
0.1 |
2.3 |
43.9 |
1.57 |
2.02 |
0.9270 |
0.7270 |
||
35 |
6.9 |
4.5 |
0.1 |
2.4 |
46.0 |
1.75 |
2.38 |
0.6680 |
0.5240 |
||
50 |
8.2 |
4.5 |
0.1 |
2.4 |
48.8 |
2.00 |
2.85 |
0.4936 |
0.3870 |
||
70 |
9.7 |
4.5 |
0.1 |
2.5 |
52.3 |
2.34 |
3.57 |
0.3420 |
0.2680 |
||
95 |
11.3 |
4.5 |
0.1 |
2.6 |
55.9 |
2.75 |
4.45 |
0.2464 |
0.1930 |
||
120 |
12.8 |
4.5 |
0.1 |
2.7 |
59.4 |
3.16 |
5.32 |
0.1955 |
0.1530 |
||
150 |
14.2 |
4.5 |
0.1 |
2.8 |
62.6 |
3.57 |
6.27 |
0.1587 |
0.1240 |
||
185 |
15.9 |
4.5 |
0.1 |
2.9 |
66.4 |
4.07 |
7.45 |
0.1271 |
0.0991 |
||
240 |
18.3 |
4.5 |
0.1 |
3.1 |
72.0 |
4.82 |
9.25 |
0.0976 |
0.0754 |
||
300 |
20.4 |
4.5 |
0.1 |
3.3 |
77.0 |
5.71 |
11.28 |
0.0778 |
0.0601 |
||
400 |
23.2 |
4.5 |
0.1 |
3.4 |
83.2 |
6.78 |
13.86 |
0.0615 |
0.0470 |
||
500 |
26.4 |
4.5 |
0.1 |
3.5 |
91.1 |
8.20 |
17.32 |
0.0487 |
0.0366 |
9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||||
mm2 |
mm |
mm |
mm2 |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
||
25 |
– |
|
|
|
|
|
|
|
|
||
35 |
6.9 |
5.5 |
0.1 |
2.4 |
50.3 |
2.00 |
2.63 |
0.8680 |
0.6680 |
||
50 |
8.2 |
5.5 |
0.1 |
2.5 |
53.3 |
2.26 |
3.11 |
0.6410 |
0.4936 |
||
70 |
9.7 |
5.5 |
0.1 |
2.6 |
56.8 |
2.62 |
3.85 |
0.4430 |
0.3420 |
||
95 |
11.3 |
5.5 |
0.1 |
2.8 |
60.6 |
3.07 |
4.77 |
0.3200 |
0.2464 |
||
120 |
12.8 |
5.5 |
0.1 |
2.9 |
64.1 |
3.49 |
5.65 |
0.2530 |
0.1955 |
||
150 |
14.2 |
5.5 |
0.1 |
3.0 |
67.3 |
3.91 |
6.61 |
0.2060 |
0.1587 |
||
185 |
15.9 |
5.5 |
0.1 |
3.1 |
71.2 |
4.44 |
7.81 |
0.1640 |
0.1271 |
||
240 |
18.3 |
5.5 |
0.1 |
3.3 |
76.8 |
5.21 |
9.64 |
0.1250 |
0.0976 |
||
300 |
20.4 |
5.5 |
0.1 |
3.3 |
81.3 |
6.10 |
11.66 |
0.1000 |
0.0778 |
||
400 |
23.2 |
5.5 |
0.1 |
3.5 |
87.7 |
7.20 |
14.28 |
0.0778 |
0.0615 |
||
500 |
26.4 |
5.5 |
0.1 |
3.8 |
96.0 |
9.15 |
17.80 |
0.0605 |
0.0487 |
10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor |
Normal Diameter of Conductor |
Normal Thickness of Insulation |
Normal Thickness of |
Normal Thickness of Outer Sheath |
Approx. |
Approx. Net Weight |
Max. D.C. Resistance of Conductor at 20ºC |
||
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||||
mm2 |
mm |
mm |
mm |
mm |
mm |
kg/m |
kg/m |
Ω/km |
Ω/km |
25 |
|
|
|
|
|
|
|
|
|
35 |
|
|
|
|
|
|
|
|
|
50 |
8.2 |
8.0 |
0.1 |
2.9 |
64.9 |
3.02 |
3.87 |
0.6410 |
0.4936 |
70 |
9.7 |
8.0 |
0.1 |
3.0 |
68.4 |
3.42 |
4.65 |
0.4430 |
0.3420 |
95 |
11.3 |
8.0 |
0.1 |
3.1 |
72.0 |
3.89 |
5.59 |
0.3200 |
0.2464 |
120 |
12.8 |
8.0 |
0.1 |
3.3 |
75.7 |
4.39 |
6.54 |
0.2530 |
0.1955 |
150 |
14.2 |
8.0 |
0.1 |
3.3 |
78.7 |
4.85 |
7.55 |
0.2060 |
0.1587 |
185 |
15.9 |
8.0 |
0.1 |
3.4 |
82.6 |
5.42 |
8.79 |
0.1640 |
0.1271 |
240 |
18.3 |
8.0 |
0.1 |
3.5 |
88.0 |
6.22 |
10.66 |
0.1250 |
0.0976 |
300 |
20.4 |
8.0 |
0.1 |
3.7 |
92.9 |
7.20 |
12.77 |
0.1000 |
0.0778 |
400 |
23.2 |
8.0 |
0.1 |
3.9 |
99.3 |
8.38 |
15.46 |
0.0778 |
0.0615 |
500 |
26.4 |
8.0 |
0.1 |
4.2 |
107.6 |
10.15 |
18.85 |
0.0605 |
0.0487 |
We are China 11kv XLPE Insulated Copper Core PVC Sheathed Power Cable, Electric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
150mm2 Copper Conductor Underground Power Cable
Hebei Huatong Factory Yjly23 Cable 240mm Medium Voltage Cable 35kv 150mm2
BS215 Standard Lion 225mm2 Aluminum Electric Wires with Steel Wire Cores ACSR Conductor
0.6/1kv Power Cable/XLPE Insulation PVC Jacket Amoured Power Cable
Raven 1/0AWG ACSR Conductor Electric Aluminum Wire with Steel Core ASTM Standard
Popular jpcable99 Products
Rubber Insulated Welding Cable
Medium Voltage XLPE Insulated Armoured Power Cable
High Quality 1*35mm2 ABC Cable
XLPE Insulated Armoured Marine Cable
High Quality ABC Overhead Cable
AAC Bare Conductor 250sqmm 315sqmm 400sqmm All Aluminium Stranded Conductor with IEC 61089
Popular Power Cable Products
4 Core Yjv22 4*70 Copper Core Low Voltage Electric Power Cable
Power Cable (Aluminum Wire Armoured)
33kv 3 Core 300mm2 XLPE Insulated Steel Wire Swa Armoured N2xsfy
Low Smoke Zero Halogen Free Copper Sheathed Lsoh Fire-Proof Power Cable
Aluminium/Copper Conductor XLPE Insulated PVC/PE Power Cable
Popular XLPE Insulated Cable Products
1*240mm2 0.6/1kv Copper Core XLPE Insulated PE Sheath Power Cable
XLPE Insulated Underground Cable 4core 240mm2 Cu/XLPE/Swa/PVC
0.6/1kv Aluminum Conductor XLPE Insulated ABC Cable
11 Kv Medium Voltage Electric Wire XLPE Insulated Power Cable
33kv Power Cables Railway Cable to BS 7835 Nr/PS/Elp/00008 XLPE Insulated Cable
Solid Core or Tightly Pressed Twisted Sector Conductor
Tags: Cable, jpcable99, Power Cable, XLPE Insulated Cable