High Quality ACSR (BS 232 standard) for Overhead Application
High Quality ACSR (BS 232 standard) for Overhead Application image
Get Latest Price Request a quote
Quick Details
Product Details
Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Relative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM
(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
Packing:
Standard export wooden drums
| Standards | IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 |
| Certificate | ISO 9001 and ISO 14001. CE ,SONCAP |
| Type | AAC, AAAC, ACSR, AACSR&ACAR conductor |
| AAC | AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. |
| AAAC | (AAAC) Conductor as per ASTM-B-399-1992 |
| ACSR | ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) |
Standard:
ASTM B230,B231,B498 Standard
| Code Name | Size | No./Dia.of Stranding Wires | Approx. Overall Dia. | Approx. Weight | Code Name | Size | No./Dia.of Stranding Wires | Approx. Overall Dia. | Approx. Weight | ||
| AWG or MCM | Aluminum | Steel | AWG or MCM | Aluminum | Steel | ||||||
| No./mm | No./mm | mm | kg/km | No./mm | No./mm | mm | kg/km | ||||
| Turkey | 6 | 6/1.68 | 1/1.68 | 5.04 | 54 | Starling | 715.5 | 26/4.21 | 7/3.28 | 26.68 | 1466 |
| Swan | 4 | 6/2.12 | 1/2.12 | 6.36 | 85 | Redwing | 715.5 | 30/3.92 | 19/2.35 | 27.43 | 1653 |
| Swanate | 4 | 7/1.96 | 1/2.61 | 6.53 | 100 | Tern | 795.0 | 45/3.38 | 7/2.25 | 27.03 | 1333 |
| Sparrow | 2 | 6/2.67 | 1/2.67 | 8.01 | 136 | Condor | 795.0 | 54/3.08 | 7/3.08 | 27.72 | 1524 |
| Sparate | 2 | 7/2.47 | 1/3.30 | 8.24 | 159 | Cuckoo | 795.0 | 24/4.62 | 7/3.08 | 27.74 | 1524 |
| Robin | 1 | 6/3.00 | 1/3.00 | 9.00 | 171 | Drake | 795.0 | 26/4.44 | 7/3.45 | 28.11 | 1628 |
| Raven | 1/0 | 6/3.37 | 1/3.37 | 10.11 | 216 | Coot | 795.0 | 36/3.77 | 1/3.77 | 26.41 | 1198 |
| Quail | 2/0 | 6/3.78 | 1/3.78 | 11.34 | 273 | Mallard | 795.0 | 30/4.14 | 19/2.48 | 28.96 | 1838 |
| Pigeon | 3/0 | 6/4.25 | 1/4.25 | 12.75 | 343 | Ruddy | 900.0 | 45/3.59 | 7/2.40 | 28.73 | 1510 |
| Penguin | 4/0 | 6/4.77 | 1/4.77 | 14.31 | 433 | Canary | 900.0 | 54/3.28 | 7/3.28 | 29.52 | 1724 |
| Waxwing | 266.8 | 18/3.09 | 1/3.09 | 15.45 | 431 | Rail | 954.0 | 45/3.70 | 7/2.47 | 29.61 | 1601 |
| Partridge | 266.8 | 26/2.57 | 7/2.00 | 16.28 | 546 | Catbird | 954.0 | 36/4.14 | 1/4.14 | 28.95 | 1438 |
| Ostrich | 300.0 | 26/2.73 | 7/2.12 | 17.28 | 614 | Cardinal | 954.0 | 54/3.38 | 7/3.38 | 30.42 | 1829 |
| Merlin | 336.4 | 18/3.47 | 1/3.47 | 17.5 | 544 | Ortlan | 1033.5 | 45/3.85 | 7/2.57 | 30.81 | 1734 |
| Linnet | 336.4 | 26/2.89 | 7/2.25 | 18.31 | 689 | Tanger | 1033.5 | 36/4.30 | 1/4.30 | 30.12 | 1556 |
| Oriole | 336.4 | 30/2.69 | 7/2.69 | 18.83 | 784 | Curlew | 1033.5 | 54/3.52 | 7/3.52 | 31.68 | 1981 |
| Chickadee | 397.5 | 18/3.77 | 1/3.77 | 18.85 | 642 | Bluejay | 1113.0 | 45/4.00 | 7/2.66 | 31.98 | 1868 |
| Brant | 397.5 | 24/3.27 | 7/2.18 | 19.61 | 762 | Finch | 1113.0 | 54/3.65 | 19/2.19 | 32.85 | 2130 |
| Ibis | 397.5 | 26/3.14 | 7/2.44 | 19.88 | 814 | Bunting | 1192.5 | 45/4.14 | 7/2.76 | 33.12 | 2001 |
| Lark | 397.5 | 30/2.92 | 7/2.92 | 20.44 | 927 | Grackle | 1192.5 | 54/3.77 | 19/2.27 | 33.97 | 2282 |
| Pelican | 477.0 | 18/4.14 | 1/4.14 | 20.70 | 771 | Bittern | 1272.0 | 45/4.27 | 7/2.85 | 34.17 | 2134 |
| Flicker | 477.0 | 24/3.58 | 7/2.39 | 21.49 | 915 | Pheasant | 1272.0 | 54/3.90 | 19/2.34 | 35.10 | 2433 |
| Hawk | 477.0 | 26/3.44 | 7/2.67 | 21.79 | 978 | Skylark | 1272.0 | 36/4.78 | 1/4.78 | 33.42 | 1917 |
| Hen | 477.0 | 30/3.20 | 7/3.20 | 22.40 | 1112 | Dipper | 1351.5 | 45/4.40 | 7/2.92 | 35.16 | 2266 |
| Osprey | 556.5 | 18/4.47 | 1/4.47 | 22.35 | 899 | Martin | 1351.5 | 54/4.02 | 19/2.41 | 36.17 | 2585 |
| Parakeet | 556.5 | 24/3.87 | 7/2.58 | 23.22 | 1067 | Bobolink | 1431.0 | 45/4.53 | 7/3.02 | 36.24 | 2402 |
| Dove | 556.5 | 26/3.72 | 7/2.89 | 23.55 | 1140 | Plover | 1431.0 | 54/4.14 | 19/2.48 | 37.24 | 2738 |
| Eagle | 556.5 | 30/3.46 | 7/3.46 | 24.21 | 1298 | Nuthatch | 1510.5 | 45/4.65 | 7/3.10 | 37.20 | 2534 |
| Peacock | 605.0 | 24/4.03 | 7/2.69 | 24.20 | 1160 | Parrot | 1510.5 | 54/4.25 | 19/2.55 | 38.25 | 2890 |
| Squab | 605.0 | 26/3.87 | 7/3.01 | 24.51 | 1240 | Lapwing | 1590.0 | 45/4.77 | 7/3.18 | 38.16 | 2667 |
| WoodDuck | 605.0 | 30/3.61 | 7/3.61 | 25.25 | 1411 | Falcon | 1590.0 | 54/4.36 | 19/2.62 | 39.26 | 3042 |
| Teal | 605.0 | 30/3.61 | 19/2.16 | 25.24 | 1399 | High Strength Stranding | |||||
| Kingbird | 636.0 | 18/4.78 | 1/4.78 | 23.88 | 1028 | Grouse | 80 | 8/2.54 | 1/4.24 | 9.32 | 222 |
| Rook | 636.0 | 24/4.14 | 7/2.76 | 24.84 | 1219 | Petrel | 101.8 | 12/2.34 | 7/2.34 | 11.71 | 378 |
| Grosbeak | 636.0 | 26/3.97 | 7/3.09 | 25.15 | 1302 | Minorca | 110.8 | 12/2.44 | 7/2.44 | 12.22 | 412 |
| Scoter | 636.0 | 30/3.70 | 7/3.70 | 25.88 | 1484 | Leghorn | 134.6 | 12/2.69 | 7/2.69 | 13.46 | 500 |
| Egret | 636.0 | 30/3.70 | 19/2.22 | 25.90 | 1470 | Guinea | 159 | 12/2.92 | 7/2.92 | 14.63 | 590 |
| Swift | 636.0 | 36/3.38 | 1/3.38 | 23.62 | 958 | Dotterel | 176.9 | 12/3.08 | 7/3.08 | 15.42 | 657 |
| Flamingo | 666.6 | 24/4.23 | 7/2.82 | 25.40 | 1278 | Dorking | 190.8 | 12/3.20 | 7/3.20 | 16.03 | 709 |
| Gannet | 666.6 | 26/4.07 | 7/3.16 | 25.76 | 1365 | Brahma | 203.2 | 16/2.86 | 19/2.48 | 18.14 | 1007 |
| Stilt | 715.5 | 24/4.39 | 7/2.92 | 26.31 | 1372 | Cochin | 211.3 | 12/3.37 | 7/3.37 | 16.84 | 785 |
We are China High Quality ACSR (BS 232 standard) for Overhead Application manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ACSR Products
DIN 48204 Standard ACSR Bare Stranded Conductor
Overhead Bare Aluminum Conductor Steel Reinforced ACSR Conductor BS215, IEC1089, Astmb232, DIN48204
Almenec Cable 117mm2 NF C 34-125
Standard Aluminum Conductor ACSR, BS, ASTM, IEC Standard
ASTM Standard Overhead ACSR Conductor
Swa /Steel Wire Armoured Cable XLPE Insulated PVC Sheath Power Cable
Popular ACSR Cable Products
National Grid Power Transmission Line BS 215 Standard ACSR Zebra
ACSR Aluminum Conductor Steel Reinforced ACSR 300/50 mm2 Cable
Overhead Diameter Expanded ACSR Power Cable for Transmission Line
ACSR for Overhead Power Transmission Line
Aluminum Bare Conductor ACSR Electric Wire Cable
Popular ACSR Conductor Products
Bare ACSR Cable Aluminum Conductor Steel Reinforced for Power Transmission
Good Quality ACSR Conductor Aluminum Conductor Steel Reinforced Conductor
Astmb232 Overhead ACSR Conductor Eagle
Aluminum Condcutor Steel Reinforced ACSR Conductor
High Quality Aluminum Conductors Steel Reinforced ACSR Conductor
Popular jpcable99 Products
Cu Core XLPE Insulated Steel Wire Armored Power Cable
High Quality 70mm2 PVC Insulated Power Cable
High Quality Hv Cu/XLPE/Swa/PVC Power Cable
1X120mm2 Precio De Energia Unipolar Tipo N2xsy Cable
New ABC Cable Self-Supporting Cable
Multi Core Control Power Cable
Tags: ACSR, ACSR Cable, ACSR Conductor, jpcable99