High Performance AAAC All Alumum Alloy Conductor
High Performance AAAC All Alumum Alloy Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
(1). All aluminium conductor (AAC)
(2). All aluminimum alloy conductor(AAAC)
(3). Aluminum conductor steel reinforced (ACSR)
(4). Anti-corrosion type ACSR
(5). Aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6). Rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7). Aluminimum conductor aluminimum alloy reinforced(ACAR)
2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.
All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.
Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.
| Code word | Size of Conductor | Stranding and Wire Diameter | Overall Diameter | Max.D.C. Resistance at 20°C | Code word | Size of Conductor | Stranding and Wire Diameter | Overall Diameter | Max.D.C. Resistance at 20°C |
| AWG or MCM | mm | mm | ohm/km | AWG or MCM | mm | mm | ohm/km | ||
| Peachbell | 6 | 7/1.554 | 4.67 | 2.1692 | Verbena | 700 | 37/3.493 | 24.45 | 0.0813 |
| Rose | 4 | 7/1.961 | 5.89 | 1.3624 | Nasturtium | 715.5 | 61/2.75 | 24.76 | 0.0795 |
| Lris | 2 | 7/2.474 | 7.42 | 0.8577 | Violet | 715.5 | 37/3.533 | 24.74 | 0.0795 |
| Pansey | 1 | 7/2.776 | 8.33 | 0.6801 | Cattail | 750 | 61/2.817 | 25.35 | 0.0759 |
| Poppy | 1/0 | 7/3.119 | 9.36 | 0.5390 | Petunia | 750 | 37/3.617 | 25.32 | 0.0759 |
| Aster | 2/0 | 7/3.503 | 10.51 | 0.4276 | Lilac | 795 | 61/2.90 | 26.11 | 0.0715 |
| Phlox | 3/0 | 7/3.932 | 11.80 | 0.3390 | Arbutus | 795 | 37/3.724 | 26.06 | 0.0715 |
| Oxlip | 4/0 | 7/4.417 | 13.26 | 0.2688 | Snapdragon | 900 | 61/3.086 | 27.78 | 0.0632 |
| Valerian | 250 | 19/2.913 | 14.57 | 0.2275 | Cockscomb | 900 | 37/3.962 | 27.73 | 0.0632 |
| Sneezewort | 250 | 7/4.80 | 14.4 | 0.2275 | Goldenrod | 954 | 61/3.177 | 28.6 | 0.0596 |
| Laurel | 266.8 | 19/3.01 | 15.05 | 0.2133 | Magnolia | 954 | 37/4.079 | 28.55 | 0.0596 |
| Daisy | 266.8 | 7/4.96 | 14.9 | 0.2133 | Camellia | 1000 | 61/3.251 | 29.36 | 0.0569 |
| Peony | 300 | 19/3.193 | 15.97 | 0.1896 | Hawkweed | 1000 | 37/4.176 | 29.23 | 0.0569 |
| Tulip | 336.4 | 19/3.381 | 16.91 | 0.1691 | Larkspur | 1033.5 | 61/3.307 | 29.76 | 0.0550 |
| Daffodil | 350 | 19/3.447 | 17.24 | 0.1625 | Bluebell | 1033.5 | 37/4.244 | 29.72 | 0.0550 |
| Canna | 397.5 | 19/3.673 | 18.36 | 0.1431 | Marigold | 1113 | 61/3.432 | 30.89 | 0.0511 |
| Goldentuft | 450 | 19/3.909 | 19.55 | 0.1264 | Hawthorn | 1192.5 | 61/3.551 | 31.05 | 0.0477 |
| Syringa | 477 | 37/2.882 | 20.19 | 0.1193 | Narcissus | 1272 | 61/3.668 | 33.02 | 0.0477 |
| Cosmos | 477 | 19/4.023 | 20.12 | 0.1193 | Columbine | 1351.5 | 61/3.78 | 34.01 | 0.0421 |
| Hyacinth | 500 | 37/2.951 | 20.65 | 0.1138 | Carnation | 1431 | 61/3.89 | 35.03 | 0.0398 |
| Zinnia | 500 | 19/4.12 | 20.6 | 0.1138 | Gladiolus | 1510.5 | 61/4.00 | 35.09 | 0.0376 |
| Dahlia | 556.5 | 19/4.346 | 21.73 | 0.1022 | Coreopsis | 1590 | 61/4.099 | 36.51 | 0.03568 |
| Mistletoe | 556.5 | 37/3.114 | 21.79 | 0.1022 | Jessamine | 1750 | 61/4.302 | 38.72 | 0.0325 |
| Meadowsweet | 600 | 37/3.233 | 22.63 | 0.0948 | Cowslip | 2000 | 91/3.76 | 41.40 | 0.02866 |
| Orchid | 636 | 37/3.33 | 23.31 | 0.0894 | Lupine | 2500 | 91/4.21 | 46.30 | 0.0230 |
| Heuchera | 650 | 37/3.366 | 23.56 | 0.0875 | Trillium | 3000 | 127/3.90 | 50.75 | 0.0192 |
| Flag | 700 | 61/2.72 | 24.48 | 0.0813 | Bluebonnet | 3500 | 127/4.21 | 54.80 | 0.01653 |
We are China High Performance AAAC All Alumum Alloy Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Products
3 Core ABC Cable PVC Insulated Aluminum Conductor
Overhead XLPE/PVC Insulated ABC Cable ASTM Standard
Almelec Cable Alliance 4/0AWG ASTM B399 Steel Reinforced Bare Aluminum ACSR Conductor
Factory AAAC Conductor AAAC Cable for Overhead Transmission
Alloy Conductor Overhead AAC Conductor All Aluminum Stranded Conductor Bare
Popular AAAC Conductor Products
Overhead Distribution Line All Aluminum Alloy Conductor Bare AAAC Conductor
All Aluminium Alloy Conductor Butte (AAAC Conductor)
Bare Conductor AAAC All Aluminum Alloy Stranded Conductor
German Sizes DIN48201 All Aluminum Alloy Condcutor AAAC 240mm2
Aluminum Alloy AAAC Bare Stranded Conductor Cable Wire
USA Sizes ASTM B399 All Aluminum Alloy Condcutor AAAC Alliance
Popular All Aluminum Alloy Conductor Products
All Aluminum Alloy Conductor for ASTM, BS, IEC
Factory Supply Different Size AAC AAAC Aluminum Alloy Conductor 75mm2 100mm2
AAAC Bare Conductor Aluminum Alloy Stranded Conductor Price
ASTM B399 Standard AAAC Conductor All Aluminum Alloy Conductor AAAC Cable
Aluminum Alloy Conductor Concentric-Lay-Stranded
DIN Standard 16mm2 25mm2 Aluminum Alloy AAAC Bare Conductor Hot Selling
Popular jpcable99 Products
3*4mm2 PVC Insulated Flexible Wire
Aluminum Alloy Strand Conductor AAC/ACSR Conductor Twisted ABC Cable
BS Standard Bare Conductor Zebra ACSR Conductor
AAC Conductor Aluminum Stranded Conductor
2018 Hot Selling XLPE Insulation PVC Sheathed Power Cable
Tags: AAAC, AAAC Conductor, All Aluminum Alloy Conductor, jpcable99