High Performance Good Price Low Voltage PVC Insulated Power Cable
High Performance Good Price Low Voltage PVC Insulated Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Unarmoured | Armoured | ||||||||
| Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | Thickness of Bedding | Thickness of Al Tape | Thickness of Sheath | Overall Dia. | jpcable99.en. Weight | |||||
| Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||||||
| mm2 | – | mm | mm | mm | kg/km | kg/km | mm | mm | mm | mm | kg/km | kg/km |
| 1.5 | 1 | 0.8 | 1.4 | 5.8 | – | 51 | – | – | – | – | – | – |
| 2.5 | 1 | 0.8 | 1.4 | 6.2 | – | 64 | – | – | – | – | – | – |
| 4 | 1 | 1 | 1.4 | 7.1 | – | 88 | – | – | – | – | – | – |
| 6 | 7 | 1 | 1.4 | 7.8 | 78 | 114 | – | – | – | – | – | – |
| 10 | 7 | 1 | 1.4 | 8.6 | 96 | 159 | 1 | 0.5 | 1.8 | 13.4 | 234 | 295 |
| 16 | 7 | 1 | 1.4 | 9.6 | 123 | 222 | 1 | 0.5 | 1.8 | 14.4 | 274 | 370 |
| 25 | 7 | 1.2 | 1.4 | 11.2 | 172 | 328 | 1 | 0.5 | 1.8 | 16 | 344 | 496 |
| 35 | 7 | 1.2 | 1.4 | 12.2 | 209 | 428 | 1 | 0.5 | 1.8 | 17 | 393 | 606 |
| 50 | 19 | 1.4 | 1.4 | 13.9 | 271 | 565 | 1 | 0.5 | 1.8 | 18.7 | 478 | 764 |
| 70 | 19 | 1.4 | 1.5 | 15.9 | 356 | 818 | 1 | 0.5 | 1.8 | 20.5 | 582 | 1020 |
| 95 | 19 | 1.6 | 1.5 | 18 | 471 | 1041 | 1 | 0.5 | 1.8 | 22.6 | 717 | 1291 |
| 120 | 37 | 1.6 | 1.6 | 19.6 | 563 | 1307 | 1 | 0.5 | 1.8 | 24 | 822 | 1545 |
| 150 | 37 | 1.8 | 1.6 | 21.3 | 684 | 1592 | 1 | 0.5 | 1.8 | 25.4 | 952 | 1857 |
| 185 | 37 | 2 | 1.7 | 23.9 | 840 | 1985 | 1 | 0.5 | 1.8 | 27.9 | 1136 | 2236 |
| 240 | 61 | 2.2 | 1.8 | 27 | 1071 | 2533 | 1 | 0.5 | 1.9 | 31 | 1404 | 2877 |
| 300 | 61 | 2.4 | 1.9 | 29.6 | 1317 | 3162 | 1.2 | 0.5 | 2.1 | 34.3 | 1722 | 3551 |
| 400 | 61 | 2.6 | 2 | 33.2 | 1666 | 4120 | 1.2 | 0.5 | 2.2 | 37.6 | 2114 | 4488 |
| 500 | 61 | 2.8 | 2.2 | 37.5 | 2089 | 5163 | 1.2 | 0.5 | 2.3 | 42.1 | 2592 | 5683 |
| 630 | 61 | 2.8 | 2.3 | 41.2 | 2581 | 6447 | 1.4 | 0.5 | 2.4 | 46.3 | 3184 | 7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
| Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |
| Al Conductor | Cu Conductor | ||||||
| – | mm2 | – | mm | mm | mm | kg/km | kg/km |
| Three Cores | 3×35 | 16 | 1.2 | 1.8 | 21.9 | 601 | 1280 |
| 3×50 | 18 | 1.4 | 1.8 | 26.5 | 829 | 1732 | |
| 3×70 | 18 | 1.4 | 1.9 | 29.2 | 1067 | 2367 | |
| 3×95 | 36 | 1.6 | 2 | 32.9 | 1409 | 2317 | |
| 3×120 | 36 | 1.6 | 2.1 | 36.2 | 1705 | 3983 | |
| 3×150 | 36 | 1.8 | 2.2 | 38.8 | 2045 | 4872 | |
| 3×185 | 36 | 2 | 2.4 | 44.8 | 2596 | 6077 | |
| 3×240 | 60 | 2.2 | 2.6 | 51.5 | 3353 | 7953 | |
| 3×300 | 60 | 2.4 | 2.7 | 54.9 | 6069 | 9820 | |
| Four Cores with Reduced Neutral | 3×35+16 | 16-7 | 1.2-1 | 1.8 | 25.5 | 764 | 1107 |
| 3×50+25 | 18-16 | 1.4-1.2 | 1.9 | 28.7 | 982 | 1410 | |
| 3×70+35 | 18-16 | 1.4-1.2 | 2.0 | 32 | 1278 | 1733 | |
| 3×95+50 | 36-18 | 1.6-1.4 | 2.2 | 37.8 | 1711 | 2656 | |
| 3×120+70 | 36-18 | 1.6-1.4 | 2.3 | 40.5 | 2065 | 3137 | |
| 3×150+70 | 36-18 | 1.8-1.4 | 2.4 | 44.8 | 2480 | 3660 | |
| 3×185+95 | 36-36 | 2-1.6 | 2.6 | 49.7 | 3086 | 4345 | |
| 3×240+120 | 60-36 | 2.2-1.6 | 2.8 | 56 | 3894 | 5441 | |
| 3×300+150 | 60-36 | 1.4-1.8 | 2.9 | 60.3 | 4834 | 6494 | |
| Four Cores | 4×25 | 16 | 1.2 | 1.8 | 22.5 | 644 | 1286 |
| 4×35 | 16 | 1.2 | 1.8 | 24.6 | 799 | 1696 | |
| 4×50 | 18 | 1.4 | 1.8 | 28.6 | 1071 | 2275 | |
| 4×70 | 18 | 1.4 | 2 | 31.6 | 1387 | 3120 | |
| 4×95 | 36 | 1.6 | 2.1 | 35.9 | 1850 | 4262 | |
| 4×120 | 36 | 1.6 | 2.2 | 38.8 | 2209 | 5247 | |
| 4×150 | 36 | 1.8 | 2.3 | 43.1 | 2714 | 6483 | |
| 4×185 | 36 | 2 | 2.5 | 48.7 | 3403 | 8045 | |
| 4×240 | 60 | 2.2 | 2.7 | 53.6 | 4290 | 10422 | |
| 4×300 | 60 | 2.4 | 2.9 | 58.8 | 5302 | 12969 | |
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
| Number of Cores | Cross-Section of Conductor | No. Of Wires | Thickness of Insulation | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||
| Al Conductor | Cu Conductor | |||||||
| – | mm2 | – | mm | mm | mm | kg/km | kg/km | |
| Three Cores | 3×10 | 7 | 1 | 1.8 | 16.6 | 281 | 465 | |
| 3×16 | 7 | 1 | 1.8 | 18.7 | 387 | 679 | ||
| 3×25 | 7 | 1.2 | 1.8 | 22.2 | 536 | 996 | ||
| 3×35 | 7 | 1.2 | 1.8 | 24.4 | 665 | 1311 | ||
| 3×50 | 19 | 1.4 | 1.9 | 28.1 | 863 | 1729 | ||
| 3×70 | 19 | 1.4 | 2 | 32.3 | 1153 | 2480 | ||
| 3×95 | 19 | 1.6 | 2.1 | 37.1 | 1563 | 3301 | ||
| 3×120 | 37 | 1.6 | 2.3 | 40.4 | 1850 | 4040 | ||
| 3×150 | 37 | 1.8 | 2.4 | 43.9 | 2258 | 5000 | ||
| 3×185 | 37 | 2 | 2.5 | 49.2 | 2819 | 6151 | ||
| 3×240 | 61 | 2.2 | 2.8 | 55.9 | 3577 | 8040 | ||
| 3×300 | 61 | 2.4 | 3 | 62.1 | 4413 | 9955 | ||
| 3×400 | 61 | 2.6 | 3.2 | 69.3 | 5512 | 12705 | ||
| Four Cores | 4×10 | 7 | 1 | 1.8 | 18.1 | 343 | 589 | |
| 4×16 | 7 | 1 | 1.8 | 20.5 | 487 | 874 | ||
| 4×25 | 7 | 1.2 | 1.8 | 24.3 | 677 | 1291 | ||
| 4×35 | 7 | 1.2 | 1.8 | 26.8 | 821 | 1681 | ||
| 4×50 | 19 | 1.4 | 2 | 31.2 | 1118 | 2273 | ||
| 4×70 | 19 | 1.4 | 2.1 | 35.8 | 1494 | 3264 | ||
| 4×95 | 19 | 1.6 | 2.3 | 41.2 | 1993 | 4312 | ||
| 4×120 | 37 | 1.6 | 2.4 | 44.8 | 2370 | 5291 | ||
| 4×150 | 37 | 1.8 | 2.5 | 48.7 | 2959 | 6615 | ||
| 4×185 | 37 | 2 | 2.7 | 54.7 | 3601 | 8044 | ||
| 4×240 | 61 | 2.2 | 3 | 62.1 | 4596 | 10547 | ||
| 4×300 | 61 | 2.4 | 3.2 | 69.1 | 5614 | 13004 | ||
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | ||||||
| STA | SWA | |||||||||||||
| STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | |||||
| mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km | |
| Three Cores | ||||||||||||||
| 3×35 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 24.7 | 28.2 | 912 | 1591 | 1447 | 2126 | |
| 3×50 | 18 | 1.4 | 1 | 0.2 | 46/1.6 | 1.9 | 2 | 29.3 | 32.8 | 1202 | 2105 | 1842 | 2745 | |
| 3×70 | 18 | 1.4 | 1.2 | 0.2 | 41/2.0 | 2.0 | 2.2 | 32.5 | 37.1 | 1520 | 2820 | 2475 | 3775 | |
| 3×95 | 36 | 1.6 | 1.2 | 0.5 | 46/2.0 | 2.1 | 2.3 | 36.5 | 40.8 | 2241 | 4049 | 2989 | 4797 | |
| 3×120 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.2 | 2.4 | 39.8 | 44.1 | 2617 | 4895 | 3435 | 5713 | |
| 3×150 | 36 | 1.8 | 1.2 | 0.5 | 43/2.5 | 2.3 | 2.5 | 42.4 | 47.8 | 3019 | 5846 | 4258 | 7085 | |
| 3×185 | 36 | 2 | 1.4 | 0.5 | 50/2.5 | 2.5 | 2.7 | 48.8 | 54.2 | 3783 | 7264 | 5219 | 8700 | |
| 3×240 | 60 | 2.2 | 1.6 | 0.5 | 58/2.5 | 2.8 | 2.9 | 56 | 61.3 | 4790 | 9390 | 6444 | 11044 | |
| 3×300 | 60 | 2.4 | 1.6 | 0.5 | 61/2.5 | 2.9 | 3.1 | 59.3 | 64.7 | 5594 | 11345 | 7458 | 13209 | |
| Four Cores with Reduced Neutral | ||||||||||||||
| 3×35+16 | 16-7 | 1.2-1 | 1 | 0.2 | 43/1.6 | 1.9 | 2 | 28.5 | 31.3 | 1107 | 1528 | 1705 | 2469 | |
| 3×50+25 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 40/2.0 | 2.0 | 2.1 | 32.2 | 36.1 | 1410 | 2044 | 2326 | 3388 | |
| 3×70+35 | 18-16 | 1.4-1.2 | 1.2 | 0.2 | 44/2.0 | 2.0 | 2.2 | 35.2 | 39.3 | 1733 | 2801 | 2762 | 4285 | |
| 3×95+50 | 36-18 | 1.6-1.4 | 1.2 | 0.5 | 41/2.5 | 2.3 | 2.5 | 42.5 | 46.3 | 2656 | 3820 | 3816 | 5925 | |
| 3×120+70 | 36-18 | 1.6-1.4 | 1.4 | 0.5 | 45/2.5 | 2.4 | 2.6 | 45.6 | 49.4 | 3137 | 4777 | 4391 | 7103 | |
| 3×150+70 | 36-18 | 1.8-1.4 | 1.4 | 0.5 | 49/2.5 | 2.6 | 2.7 | 49.9 | 53.6 | 3660 | 5709 | 5043 | 8272 | |
| 3×185+95 | 36-36 | 2-1.6 | 1.4 | 0.5 | 55/2.5 | 2.6 | 2.9 | 54.5 | 58.5 | 3445 | 7171 | 5902 | 9987 | |
| 3×240+120 | 60-36 | 2.2-1.6 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3.1 | 61.6 | 65.3 | 5441 | 9272 | 7174 | 12552 | |
| 3×300+150 | 60-36 | 1.4-1.8 | 1.6 | 0.5 | 67/2.5 | 3.8 | 3.2 | 65.9 | 69.6 | 6494 | 11546 | 8355 | 15067 | |
| Four Cores | ||||||||||||||
| 4×25 | 16 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.9 | 25.3 | 28 | 934 | 1576 | 1450 | 2092 | |
| 4×35 | 16 | 1.2 | 1 | 0.2 | 41/1.6 | 1.8 | 1.9 | 27.4 | 30.2 | 1120 | 2017 | 1681 | 2578 | |
| 4×50 | 18 | 1.4 | 1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.6 | 35.6 | 1454 | 2658 | 2336 | 3540 | |
| 4×70 | 18 | 1.4 | 1.2 | 0.5 | 43/2.0 | 2.1 | 2.2 | 36.3 | 39 | 2183 | 3916 | 2840 | 4573 | |
| 4×95 | 36 | 1.6 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.4 | 40.6 | 44.1 | 2748 | 5160 | 3545 | 5957 | |
| 4×120 | 36 | 1.6 | 1.4 | 0.5 | 42/2.5 | 2.4 | 2.5 | 43.9 | 47.2 | 3237 | 6214 | 4334 | 7372 | |
| 4×150 | 36 | 1.8 | 1.4 | 0.5 | 48/2.5 | 2.5 | 2.6 | 48.3 | 52 | 3853 | 7622 | 5148 | 8917 | |
| 4×185 | 36 | 2 | 1.6 | 0.5 | 54/2.5 | 2.7 | 2.8 | 54.3 | 57.6 | 4756 | 9323 | 6132 | 10774 | |
| 4×240 | 60 | 2.2 | 1.6 | 0.5 | 59/2.5 | 2.9 | 3 | 59.2 | 62.9 | 5774 | 11906 | 7374 | 13506 | |
| 4×300 | 60 | 2.4 | 1.6 | 0.5 | 65/2.5 | 3 | 3.2 | 64.3 | 68.1 | 6922 | 14589 | 8624 | 16291 | |
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
| Cross Section of Conductor | No. of Wires | Thickness of Insulation | Thickness of Inner Sheath | Thickness of Steel Tape | No./Dia. Of Steel Wires | Thickness of Sheath | Overall Diameter | Approx. Net Weight | |||||
| STA | SWA | ||||||||||||
| STA | SWA | STA | SWA | STA | SWA | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm2 | – | mm | mm | mm | No./mm | mm | mm | mm | mm | kg/km | kg/km | kg/km | kg/km |
| Three Cores | |||||||||||||
| 3×10 | 7 | 1 | 1 | 0.2 | 35/1.25 | 1.8 | 1.8 | 19.4 | 21.5 | 494 | 679 | 988 | 1172 |
| 3×16 | 7 | 1 | 1 | 0.2 | 32/1.6 | 1.8 | 1.8 | 21.5 | 24.3 | 604 | 895 | 1051 | 1343 |
| 3×25 | 7 | 1.2 | 1 | 0.2 | 38/1.6 | 1.8 | 1.8 | 25 | 27.9 | 791 | 1252 | 1329 | 1790 |
| 3×35 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 950 | 1595 | 1551 | 2196 |
| 3×50 | 19 | 1.4 | 1.1 | 0.2 | 39/2.0 | 2 | 2.1 | 31.3 | 35.2 | 1213 | 2079 | 2128 | 2994 |
| 3×70 | 19 | 1.4 | 1.2 | 0.5 | 45/2.0 | 2.1 | 2.2 | 35.6 | 40.1 | 1567 | 2894 | 2678 | 4005 |
| 3×95 | 19 | 1.6 | 1.3 | 0.5 | 42/2.5 | 2.3 | 2.4 | 42 | 46.2 | 2449 | 4188 | 3689 | 5428 |
| 3×120 | 37 | 1.6 | 1.3 | 0.5 | 45/2.5 | 2.4 | 2.5 | 45.3 | 49.6 | 2823 | 5014 | 4174 | 6364 |
| 3×150 | 37 | 1.8 | 1.4 | 0.5 | 49/2.5 | 2.5 | 2.7 | 48.9 | 53.2 | 3327 | 6069 | 4795 | 7537 |
| 3×185 | 37 | 2 | 1.5 | 0.5 | 56/2.5 | 2.7 | 2.8 | 54.5 | 58.7 | 4038 | 7371 | 5686 | 9019 |
| 3×240 | 61 | 2.2 | 1.6 | 0.5 | 63/2.5 | 2.9 | 3.1 | 61.4 | 65.2 | 4994 | 9457 | 6862 | 11325 |
| 3×300 | 61 | 2.4 | 1.7 | 0.5 | 70/2.5 | 3.2 | 3.3 | 67.9 | 71.7 | 6022 | 11564 | 8101 | 13643 |
| 3×400 | 61 | 2.6 | 1.9 | 0.5 | 62/3.15 | 3.4 | 3.6 | 75.4 | 80.5 | 7350 | 14543 | 10535 | 17728 |
| Four Cores | |||||||||||||
| 4×10 | 7 | 1 | 1 | 0.2 | 39/1.25 | 1.8 | 1.8 | 20.9 | 23 | 552 | 798 | 1073 | 1319 |
| 4×16 | 7 | 1 | 1 | 0.2 | 35/1.6 | 1.8 | 1.8 | 23.3 | 26.1 | 723 | 1110 | 1213 | 1601 |
| 4×25 | 7 | 1.2 | 1 | 0.2 | 42/1.6 | 1.8 | 1.9 | 27.2 | 30.2 | 959 | 1573 | 1559 | 2173 |
| 4×35 | 7 | 1.2 | 1 | 0.2 | 37/2.0 | 1.9 | 2 | 29.7 | 33.6 | 1140 | 2000 | 2006 | 2866 |
| 4×50 | 19 | 1.4 | 1.2 | 0.2 | 44/2.0 | 2.1 | 2.2 | 34.6 | 38.4 | 1524 | 2679 | 2541 | 3696 |
| 4×70 | 19 | 1.4 | 1.2 | 0.5 | 50/2.0 | 2.3 | 2.3 | 40.5 | 43.7 | 2338 | 4107 | 3187 | 4956 |
| 4×95 | 19 | 1.6 | 1.2 | 0.5 | 46/2.5 | 2.4 | 2.6 | 45.9 | 50.2 | 2955 | 5274 | 4325 | 6644 |
| 4×120 | 37 | 1.6 | 1.4 | 0.5 | 51/2.5 | 2.6 | 2.7 | 50 | 54.2 | 3466 | 6387 | 4568 | 7888 |
| 4×150 | 37 | 1.8 | 1.4 | 0.5 | 55/2.5 | 2.7 | 2.8 | 53.8 | 58.1 | 4144 | 7800 | 5772 | 9428 |
| 4×185 | 37 | 2 | 1.6 | 0.5 | 62/2.5 | 2.9 | 3 | 60.2 | 64.5 | 4987 | 9430 | 6822 | 11266 |
| 4×240 | 61 | 2.2 | 1.6 | 0.5 | 70/2.5 | 3.1 | 3.3 | 67.7 | 71.5 | 6161 | 12111 | 8233 | 14184 |
| 4×300 | 61 | 2.4 | 1.6 | 0.5 | |||||||||
6)Workshop
We are China High Performance Good Price Low Voltage PVC Insulated Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jpcable99 Products
8.7/15kv Copper XLPE Insulated Unarmoured Power Cable
Copper Core PVC Insulated Flame Retardant Power Cable
70mm2 Bare Conductor ACSR Conductor
Conductor De Al. Tipo AAAC De 120mm2 Cableado De 19 Hilos
150mm Copper Conductor XLPE Insulated Armoured Power Cable
Popular PVC Cable Products
Flexible PVC Insulated Electrical Wires Power Cable
95mm2 PVC Insulated 600V Electric Wire Steel Tape Armored Power Cable
Cyky-J, O, Power/Control Cable, 450/750 V, Cu/PVC/PVC (CSN 347656, CSN 347615)
PVC/XLPE Insulation Copper Conductor Armoured Cable
High Voltage PVC Insulation Power Cable Electric Wire
High Quality Low Price Flat Electrical Cable Wire 10mm
Popular PVC Insulated Cable Products
1.5mm Hook up Wire Electrical Cable
Medium Voltage 3 4 Cores Copper Conductor Armoured XLPE Insulated Power Cable
High Performance Low Voltage PVC Insulated Power Cable
Copper Cable Underground Used Steel Armored PVC Insulated Cable XLPE Insulated Cable
Multi Core 1mm2 2.5mm2 4mm2 Flexible Electric Cable PVC Control Cable
Low/Medium Voltage XLPE Insulated Steel Wire Armoured Power Cable
Popular PVC Insulated Power Cable Products
11kv High Voltage 300mm 150mm XLPE Insulated PVC Sheathed Steel Copper Tape Armored Power Cable
Fire Resistant XLPE Insulated Power Cables
Aluminum Conductor Copper Steel Tape Armoured XLPE Power Cable
2 4 6 AWG 10 Sq mm 16 Sq mm 4 Core XLPE/Swa/PVC Copper Power Cable Price Per Kg
Custom Insulated Single Core Armoured Cable Electric Copper Power Wire Cable
Cable Copper Conductor Flexible 5 Core Power Cable