Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire

China 
                        Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire
                      manufacture and supplier

Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire image

Get Latest Price Request a quote

Quick Details

Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire

Douplex/Triple/Quadruplex Service Drop ABC Cable

Renda

ABC Cable, Service Drop Wire

ISO, CCC, CE, RoHS, UL, VDE, TUV, Psb, SABS, Kema

Aluminum or Copper

Round Wire

No Sheath

XLPE, PE

DC & AC

Low and Medium Voltage Cable

Construction, Overhead, Industrial, Power Station

600V, 0.6/1kv

IEC502, 227, NF C 33-209

ABC Cable, Aerial Bundle Cable

16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2

as Your Requirements

Service Drop Cable ABC Cable

Duplex / Triplex/ Quadruplex

4-477 AWG or Kcmil

Free Sample Available

Losh, Anti UV

RNEDA

Standard Export Wooden Reel or Coil

IEC, BS, DIN, ASTM, IECA NFC

Tangshan. Hebei. China

8544492100

Product Details

0.6/1kv Power Aluminum Conductor XLPE Insulated Cable
Overhead Aerial Bundle Cable
Duplex/Triple/Quadruplex Service Drop/URD/ABC Cable

=========================================================
Professional OEM manufacturer

Top ten cable manufactuer in China

Leading ESP cable manufacture, largest Rubber cable manufacturer in China.

With UL,TUV,KEMA,CE,BV,PSB,SABA certifications

With TUV TYPE TESTING REPORT
With ISO9001,ISO18001,OHSAS18001 syetem certifications
=========================================================
We produce the ABC Electric Cable used for the overhead line(duplex, triplex, quadruplex) in IEC standard, ASTM ANSI/ICEA S-76-474   NF C 33-209 standard.

LV ABC cable(Aerial Bundle cable) with AAAC conductor
Service Drop Cable(ABC CABLE) is mainly used for electric power transmission, Duplex, Triplex, Quadruplex.
Service Drop Cable(ABC CABLE) is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve safety and reliance of electrified wire netting.


TYPE ONE Service Drop wire ABC CABLE
ABC CABLE -aerial bundle cable: is mainly used for electric power transmission, rebuilding of urban and forest regions. They can improve safety and reliance of electrified wire netting.

 Applications: To supply 120-volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction

Phase Conductor construction: The phase conductor is aluminum alloy 1350-H19 hard-drawn, compressed concentric-lay-stranded.

Neutral Conductor Construction
Cable assemblies are available with the following neutral conductors:

Aluminum conductors, coated-steel reinforced (ACSR), concentric-lay-stranded

Aluminum alloy 1350-H19 hard-drawn, concentric-lay-stranded

Aluminum alloy 6201-T81, concentric-lay-stranded
Insulation Material
The standard insulation on the phase conductor is black low-density crosslinked polyethylene (XLPE)

Alternatively, black linear low-density polyethylene (LLDPE) insulation with a 75°C temperature rating is available upon request. 
Standards
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

 Duplex Service Drop-Aluminum Conductor
 

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size *Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
AAC
Pekingese 6 solid 45 6 7/w 563 63.5 61.7 70 70
Collie 6 7/w 45 6 7/w 563 66.8 63.1 70 70
Dachshund 4 solid 45 4 7/w 881 95.5 93.4 90 90
Spaniel 4 7/w 45 4 7/w 881 101 95.4 90 90
Doberman 2 7/w 45 2 7/w 1,350 153 145.7 120 120
Malemute 1/0 19/w 60 1/0 7/w 1,990 243 234.2 160 160
ACSR NEUTRAL-MESSENGER
Setter 6 solid 45 6 ‘6/1 1.19 75 73.2 70 70
Shepherd 6 7/w 45 6 ‘6/2 1.19 78.3 74.6 70 70
Eskimo 4 solid 45 4 ‘6/3 1.86 114 111.6 90 90
Terrier 4 7/w 45 4 ‘6/4 1.86 119 113.6 90 90
Chow 2 7/w 45 2 ‘6/5 2.85 182 174.7 120 120
Bull 1/0 19/w 60 1/0 ‘6/6 4.38 289 280.3 160 160
6201 ALLOY NEUTRAL-MESSENGER
Chihuahua 6 solid 45 6 7/w 1,110 67.6 65.8 70 70
Vizsla 6 7/w 45 6 7/w 1,110 70.9 67.2 70 70
Harrier 4 solid 45 4 7/w 1,760 102 99.9 90 90
Whippet 4 7/w 45 4 7/w 1,760 107 101.9 90 90
Schnauzer 2 7/w 45 2 7/w 2,800 163 156.2 120 120
Heeler 1/0 19/w 60 1/0 7/w 4,460 259 250.8 160 160

 Triplex Service Drop-Aluminum Conductor

Code Phase Conductor Bare Neutral Messenger Weight Per Ampacity (Amps)
Name 1000 ft(lbs)
  Size Stranding Insulation Size Stranding Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 solid 45 6 7 1,110 106.6 102.9 85 70
Hippa 6 7/w 45 6 7 1,110 113.2 105.7 85 70
Prawn 4 solid 45 4 7 1,760 158.4 154.1 115 90
Barnacles 4 7/w 45 4 7 1,760 168.3 158.2 115 90
Shrimp 2 7/w 45 2 7 2,800 253.7 239.7 150 120
Gammarus 1/0 7/w 60 1/0 7 4,460 411.7 386 205 160
Leda 1/0 19/w 60 1/0 7 4,460 402.7 386 205 160
Dungenese 2/0 7/w 60 2/0 7 5,390 506.8 476.3 235 185
Cyclops 2/0 19/w 60 2/0 7 5,390 495.3 476.3 235 185
Flustra 3/0 19/w 60 3/0 7 6,790 611.4 589.1 275 215
Lepas 4/0 19/w 60 4/0 7 8,560 757.1 730.5 315 245
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 solid 45 6 7 1,110 141.4 137.1 115 90
Crab 4 7/w 45 6 7 1,110 151.3 141.2 115 90
Solaster 2 7/w 45 4 7 1,760 226.6 212.6 150 120
Sandcrab 1/0 7/w 60 2 7 2,800 368.8 343.1 205 160
Echinus 1/0 19/w 60 2 7 2,800 358.8 343.1 205 160
Crayfish 2/0 7/w 60 1 7 3,530 452.6 422.5 235 185
Sipho 2/0 19/w 60 1 7 3,530 441 422.5 235 185
Fulgar 3/0 19/w 60 1/0 7 4,460 543.4 521.1 275 215
Arca 4/0 19/w 60 2/0 7 5,390 671.2 644.6 315 245
AAC NEUTRAL-MESSENGER
Haiotis 6 solid 45 6 7 563 102.5 98.8 85 70
Patella 6 7/w 45 6 7 563 109.1 101.6 85 70
Fusus 4 solid 45 4 7 881 151.9 147.6 115 90
Oyster 4 7/w 45 4 7 881 161.8 151.7 115 90
Clam 2 7/w 45 2 7 1,350 243.2 229.2 150 120
Murex 1/0 7/w 60 1/0 7 1,990 395.1 369.4 205 160
Purpura 1/0 19/w 60 1/0 7 1,990 386.1 369.4 205 160
Nassa 2/0 7/w 60 2/0 7 2,510 485.8 455.3 235 185
Melita 3/0 19/w 60 3/0 19 3,310 585.2 562.9 275 215
Portunus 4/0 19/w 60 4/0 19 4,020 723.9 697.3 315 245
Nannynose 336.4 19/w 80 336 19 6,146 1160 1118 420 325
WITH FULL SIZE ACSR MESSENGER
Paludina 6 solid 45 6 ‘6/1 1,190 114 113 85 70
Voluta 6 7/w 45 6 ‘6/1 1,190 120 113 85 70
Whelk 4 solid 45 4 ‘6/1 1,860 169 165 115 90
Periwinkle 4 7/w 45 4 ‘6/1 1,860 176 172 115 90
Conch 2 7/w 45 2 ‘6/1 2,850 267 261 150 120
Neritina 1/0 7/w 60 1/0 ‘6/1 4,380 530 419 205 160
Cenia 1/0 19/w 60 1/0 ‘6/1 4,380 426 416 205 160
Runcina 2/0 7/w 60 2/0 ‘6/1 5,310 530 519 235 185
Triton 2/0 19/w 60 2/0 ‘6/1 5,310 526 514 235 185
Cherrystone 3/0 7/w 60 3/0 ‘6/1 6,620 656 643 250 200
Mursia 3/0 19/w 60 3/0 ‘6/1 6,620 650 638 250 200
Razor 4/0 7/w 60 4/0 ‘6/1 8,350 814 799 315 245
Zuzara 4/0 19/w 60 4/0 ‘6/1 8,350 805 792 315 245
Limpet 336.4 19/w 80 336 ‘6/1 8,680 1209 1167 420 325
WITH ACSR REDUCED SIZE MESSENGER
Scallop 4 Solid 45 6 ‘6/1 1,190 148 144 115 90
Strombus 4 7/w 45 6 ‘6/1 1,190 158 148 115 90
Cockle 2 7/ w 45 4 ‘6/1 1,860 233 227 150 120
Janthina 1/0 7/ w 60 2 ‘6/1 2,850 376 365 205 160
Ranella 1/0 19/ w 60 2 ‘6/1 2,850 372 362 205 160

Quadruplex Service Drop-Aluminum Conductor

Code Phase Conductor Bare Neutral Messenger Weight Per Rating(Amps)
Name 1000 ft(lbs)
  Size Strand Insulation Size Strand Breaking XLP POLY XLP POLY
  AWG thickness AWG strength
    (MLS)   (lbs)
AAC NEUTRAL-MESSNGER
Clydesdale 4 Solid 45 4 7 881 208 201.8 100 80
Pinto 4 7/w 45 4 7 881 223 207.9 100 80
Mustang 2 7/w 45 2 7 1,350 333 312.6 135 105
Criollo 1/0 19/w 60 1/0 7 1,990 529 504.5 180 140
Percheron 2/0 19/w 60 2/0 7 2,510 649 620.5 205 160
Hanoverian 3/0 19/w 60 3/0 19 3,310 799 765.6 235 185
Oldenburg 4/0 19/w 60 4/0 19 4,020 986 946.7 275 210
Lippizaner 336.4 19/w 80 336.4 19 6,146 1,546 1,519.20 370 280
ACSR NEUTRAL-MESSNGER
Morochuca 6 Solid 45 6 ‘6/1 1,190 152 147.4 75 60
Chola 6 7/w 45 6 ‘6/1 1,190 162 151.7 75 60
Morgan 4 Solid 45 4 ‘6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 ‘6/1 1,860 241 226.1 100 80
Palomino 2 7/w 45 2 ‘6/1 2,850 362 342.6 135 105
Costena 1/0 19/w 60 1/0 ‘6/1 4,380 575 550.6 180 140
Grullo 2/0 19/w 60 2/0 ‘6/1 5,310 707 678.7 205 160
Suffolk 3/0 19/w 60 3/0 ‘6/1 6,620 872 838.9 235 185
Appaloosa 4/0 19/w 60 4/0 ‘6/1 8,350 1079 1039.2 275 210
Bronco 336.4 19/w 80 336.4 ’18/1 8,580 1613 1568.2 370 280
Gelding 336.4 19/w 80 4/0 ‘6/1 8,350 1548 1494.3 370 280
 
6201 ALLOY NEUTRAL-MESSENGER
Bay 6 Solid 45 6 7 1,110 145 140 75 60
French Coach 6 7/w 45 6 7 1,110 155 144.3 75 60
German Coach 4 Solid 45 4 7 1,760 214 208.3 100 80
Arabian 4 7/w 45 4 7 1,760 229 214.4 100 80
Belgian 2 7/w 45 2 7 2,800 344 323.1 135 105
Shetland 1/0 19/w 60 1/0 7 4,460 546 521.1 180 140
Thoroughbred 2/0 19/w 60 2/0 7 5,390 670 641.5 205 160
Trotter 3/0 19/w 60 3/0 7 6,790 825 791.8 235 185
Walking  4/0 19/w 60 4/0 7 8,560 1019 979.7 275 210

TYPE TWO 0.6/1kv Aluminum Core Aerial Bundled Cable ABC Cable
Standards:
GB12527-91,IEC502, BS7870-5
Other standards such as BS, DIN, and ICEA upon request
Constructions:
Conductor: Round, stranded and compacted aluminum conductor
Insulation: HDPE, XLPE, PVC
Application:
Aerial Bunch Cables are a compromise construction between Power cables and Overhead conductors. It is preferred to use ABC cables instead of uninsulated conductors at low voltage networks. ABC cables are especially used in areas where the cost of underground networks is expensive and also for the electrification of rural areas like villages. Bundles can include one or two additional conductors for public lighting and control pairs.
Specifications:
 

Cross Section of Conductor  Min.Nos. of Wires for Conductor Insulation Thickness Average Max. O.D.per Single-core  Max.Conductor Resistance at 20ºC  Min Insulated Resistance at Rated Working Temperature Cable Tensile Breaking Force
(mm2) (mm) (mm) (mm) (Ω/km) (MΩ.km)
             
2×10 6 1 6.5×13.0 3.08 0.0067 0.67 1650
2×16 6 1.2 8.0×16.0 1.91 0.0065 0.65 2512
2×25 6 1.2 9.4×18.8 1.2 0.0054 0.54 3762
2×35 6 1.4 11.0×22.0 0.868 0.0054 0.54 5177
2×50 6 1.4 12.3×24.6 0.641 0.0046 0.46 7011
2×70 12 1.4 14.1×28.2 0.443 0.004 0.4 10354
2×95 15 1.6 16.5×33.0 0.32 0.0039 0.39 13727
2×120 15 1.6 18.1×36.2 0.252 0.0035 0.35 17339
2×150 15 1.8 20.2×40.4 0.206 0.0035 0.35 21033
2×185 30 2 22.5×45.0 0.164 0.0035 0.35 26732
2×240 30 2.2 25.6×51.2 0.125 0.0034 0.34 34679
4×10 6 1 6.5×26.0 3.08 0.0067 0.67 1650
4×16 6 1.2 8.0×32.0 1.91 0.0065 0.65 2512
4×25 6 1.2 9.4×37.6 1.2 0.0054 0.54 3762
4×35 6 1.4 11.0×44.0 0.868 0.0054 0.54 5177
4×50 6 1.4 12.3×49.2 0.641 0.0046 0.46 7011
4×70 12 1.4 14.1×56.4 0.443 0.004 0.4 10354
4×95 15 1.6 16.5×66.0 0.32 0.0039 0.39 13727
4×120 15 1.6 18.1×72.4 0.252 0.0035 0.35 17339
4×150 15 1.8 20.2×80.8 0.206 0.0035 0.35 21033
4×185 30 2 22.5×90.0 0.164 0.0035 0.35 26732
4×240 30 2.2 25.6×102.4 0.125 0.0034 0.34 3467

=========================================================

We are China Electric 0.6/1kv Power Aluminum Conductor XLPE Insulated Overhead Aerial Bundle Cable, Duplex/Triple/Quadruplex Service Drop/Urd/ABC Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular ABC Cable Products

Factory Direct LV 0.6/1kv ASTM IEC BS Standards Aerial Bundled Cable Aluminum Conductor ABC Cable

35kv 11kv 3 X 300mm2 3X 400mm2 XLPE Insulation Soft Copper Tape Screened Steel Wire Armoured Cabel Water Proof PVC Sheath Cable

ABC Cable Insulated Overhead Aerial Bundled Cable

Aerial Twisted Aluminum Core 50mm2 ABC Cable

Low and Medium Voltage ABC Cable with PVC or XLPE Insulation

Overhead ABC Cable Transmission and Distribution Areial Bundle Cable ABC

Popular huatongcables Products

Electrical Flexible Rubber Welding Wire Cable 50/70/95/120/150mm2 Aluminum Copper for Industrial

12/20kv Single Core 1X240mm2 1X300mm2 N2xsy / Na2xsy Cws Power Cable

Mtw Cable 12AWG Mtw 14AWG Wire Cable

Flexible Tinned Copper 10mm2 Solar DC Cable TUV Certificate

Insulated Stranded Cu Cable 14 12 10 8 6 4 2AWG Electrical Wire T90 Nylon UL Thhn

UL1072 Standard Single Core Copper or Aluminum 500mcm 750mcm 1000mcm Medium Voltage 5kv 8kv 15kv 25kv 35kv Mv90 Cable

Popular Overhead Cable Products

Factory 10kv Overhead Aluminum/Alloy Conductor Steel Reinforced XLPE Insulated Aerial Bundle Cable ABC/AAAC/ACSR of Power Transmission Line

Overhead Cable Concentric AAAC 8000 Series 3*8AWG XLPE 0.6/1kv

Overhead Duplex Aluminum Service Drop & Ud ASTM Standard ABC Cable

ACSR Overhead Aluminum Aerial Bundle Duplex/Triplex Service Drop Cable

Aerial Bundle Cable for Overhead Transmission Cabo Al Quadruplex

33kv XLPE Covered Aluminum Alloy Conductors Overhead Cable for Power Distribution Line

Popular Power Cable Products

Low Voltage Power Cable Lead Sheath 10X2.5 mm2

PVC Insulated Copper Wire Electric Wire Company Cable

0.6/1kv 18AWG PVC Alarm Power Cable Armoured Cable