18/30kv Medium Voltage Power Cables Single Cores Cables

China 
                        18/30kv Medium Voltage Power Cables Single Cores Cables
                      manufacture and supplier

18/30kv Medium Voltage Power Cables Single Cores Cables image

Get Latest Price Request a quote

Quick Details

18/30kv Medium Voltage Power Cables Single Cores Cables

N2XSEY, N2XSEBY, N2XSEFGBY, N2XSERY

Jl

N2xsey, N2xseby, N2xsefgby, N2xsery

CCC, CE

Cu or Al

Round Wire

PE/PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Underground, Power Station

18/30kv

3

IEC 60502-2

JL

Wooden Drum/Steel Drum

1.5-500Mm2

Jiangsu, China

8544492100

Product Details

18/30kv MV Power Cables Single Cores Cables Standards
IEC 60502 Part 2(3.6/6KV to 18/30KV) 

18/30kv MV Power Cables Single Cores Cables Application
The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations. 

18/30kv MV Power Cables Single Cores Cables Construction

Conductor: Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2. 
Conductor Screen: 
The conductor screen consists of an extruded layer of non metallic, semi-conducting compound applied on top of a semi-conducting tape. 
Insulation: XLPE

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV 3.6/6KV 6/10KV 8.7/15KV 12/20KV 18/30KV 21/35KV 26/35KV
(Um=3.6KV) (Um=7.2KV) (Um=12KV) (Um=17.5KV) (Um=24KV) (Um=36KV) (Um=42KV) (Um=42KV)
mm2 mm mm mm mm mm mm mm mm 
  XLPE XLPE XLPE XLPE XLPE XLPE XLPE XLPE
10 2 2.5
16 2 2.5 3.4
25 2 2.5 3.4 4.5
35 2 2.5 3.4 4.5 5.5
50 – 185 2 2.5 3.4 4.5 5.5 8 9.3 10.5
240 2 2.6 3.4 4.5 5.5 8 9.3 10.5
300 2 2.8 3.4 4.5 5.5 8 9.3 10.5
400 2 3 3.4 4.5 5.5 8 9.3 10.5
500 – 1600 2.2-2.8 3.2 3.4 4.5 5.5 8 9.3 10.5

Insulaton Screen:   extruded layer of semi-conducting cross-link compound
Metallic Screen:Copper tape screen or copper wire with helically copper wires
Inner Covering & Fillers: The inner covering and fillers are made of non hygroscopic material like polypropylene. 
Separation Sheath (for armoured cable): The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour. 
Lapped Bedding: The lapped bedding consists of Polyester non woven fabrics. 
Armour (for armoured cable): It consists of either flat galvanized steel wire armour (strip), round galvanized steel wire armour, and double steel tape armour. 
Outer Sheath: PVC, PE, LSZH
Installation and operation condition of cable

Operating Temperature: Up to 90°C
Short Circuit Temperature( 5 seconds maximum duration ): 250°C
Bending Radius: 12 X OD
Current Rating Conditions: 
Ground Temperature: 
20°C
Ambient Temperature (air): 30°C
Depth of Soil: 0.8m
Thermal Resistance of Soil: 1.5K•m/W 

Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage
(RMS)
18/30KV 36KV 63KV

18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Dimensional Data: 

Nom. 
Cross-Section Area
Nom. 
Insulation Thickness
Copper Tape Thickness Copper Wire Screen Area* Unarmoured Cables Steel Wire Armoured Cables
Nom. 
Sheath Thickness
Approx. 
Overall Diameter
Approx. 
Weight
Nom. 
Bedding Thickness
Armour Wire Size Nom. 
Sheath Thickness
Approx. 
Overall Diameter
Approx. 
Weight
CU AL CU AL
mm2 mm mm mm2 mm mm Kg/km mm mm mm mm Kg/km
50 8 0.1 16 3.2 65 4340 3460 1.8 3.15 3.5 75 8950 8080
70 8 0.1 16 3.3 70 5220 3930 1.9 3.15 3.6 80 10150 8860
95 8 0.1 16 3.4 74 6240 4440 1.9 3.15 3.7 84 11390 9590
120 8 0.1 16 3.5 77 7180 4910 2 3.5 3.8 89 13200 10860
150 8 0.1 25 3.6 80 8220 5420 2.1 3.5 4 92 14520 11720
185 8 0.1 25 3.7 84 9540 6040 2.1 4 4.1 97 17020 13510
240 8 0.1 25 3.9 91 11720 7110 2.2 4 4.3 104 19810 15200
300 8 0.1 25 4 95 13790 8000 2.3 4.5 4.5 108 23310 17470
400 8 0.1 35 4.3 103 16820 9430 2.4 4.5 4.7 117 27010 19620
500 8 0.1 35 4.5 110 21550 12880 2.5 4.5 4.9 124 31130 22610

Nominal screen area, as stated in the table, can be supplied as standard. 

Nom. 
Cross-Section
Area
Steel Flat Wire Armoured Cables Double Steel Tape Armoured Cables
Nom. 
Bedding Thickness
Armour Wire Size Nom. 
Sheath Thickness
Approx. 
Overall Diameter
Approx. 
Weight
Nom. 
Bedding Thickness
No of Steel Tapes X Nom Tape Thickness Nom. 
Sheath Thickness
Approx. 
Overall Diameter
Approx. 
Weight
CU AL CU AL
mm2 mm mm mm mm Kg/km mm mm mm mm Kg/km
50 1.8 0.8 3.1 70.2 7490 6775 1.8 2X0.5 3.3 71.2 7300 6585
70 1.9 0.8 3.2 74 8590 7540 1.9 2X0.5 3.4 75 8390 7335
95 1.9 0.8 3.4 78.5 9990 8460 1.9 2X0.5 3.5 79.3 9740 8210
120 2 0.8 3.5 82.2 11250 9270 2 2X0.8 3.6 84.5 11845 9875
150 2.1 0.8 3.6 85.6 12510 10070 2.1 2X0.8 3.7 87.9 13120 10700
185 2.1 0.8 3.7 89.8 14155 11100 2.1 2X0.8 3.9 92.3 14850 11800
240 2.2 0.8 3.8 95.4 16740 12575 2.2 2X0.8 4 97.9 17480 13320
300 2.3 0.8 4 100.9 19310 14120 2.3 2X0.8 4.2 103.4 20080 14900
400 2.4 0.8 4.2 107.8 22840 16170 2.4 2X0.8 4.4 110.3 23660 17000
500 2.5 0.8 4.4 115.5 27200 18610 2.5 2X0.8 4.6 118 28080 19510

18/30KV (Um=36KV) Power Cables Three Cores Cables to IEC 60502 Electrical Data 

Nom. Cross- Section Area D C Resistance
CU / AL
A C Resistance
CU / AL
Short Circuit Rating of Conductor
CU / AL
(1 sec)
Capaci tance Charging Current Short Circuit Rating of Copper Wire Screen Per Core(1 sec) Short Circuit Rating of Copper Tape Screen Per Core(1 sec) Reactance Inductance
50 387/641 494/822 6.8/4.4 142 0.85 2.6 1 134 430
70 268/443 343/568 9.8/6.3 159 0.95 2.6 1 127 400
95 193/320 248/410 13.3/8.5 175 1.05 2.6 1.1 121 390
120 153/253 196/325 17.2/11.0 189 1.13 2.6 1.1 117 370
150 124/206 159/265 21.2/13.5 201 1.21 4.3 1.2 113 360
185 99.1/164 128/211 26.6/17.0 217 1.3 4.3 1.2 109 350
240 75.4/125 98/161 34.9/22.3 237 1.42 4.3 1.3 104 330
300 60.1/100 80/130 43.8/28.0 258 1.55 4.3 1.4 101 320
400 47.0/77.8 64/102 57.3/36.6 282 1.69 5.8 1.5 96 290
500 36.6/60.5 51/81 72.3/46.2 302 1.79 5.8 1.6 78 250

We are China 18/30kv Medium Voltage Power Cables Single Cores Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Insulated Power Cable Products

Underground Power Cable Aluminum or Copper

Factory Outlet #1 1/0 2 3/0 3 5 AWG #5 8 Gauge Occ Pure Copper Welding Wire Price List

8.7/15kv Medium Voltage Power Cables Three Cores Cables

2 4 6 AWG 10 Sq mm 16 Sq mm 4 Core XLPE/Swa/PVC Copper Power Cable Price Per Kg

XLPE Insulated, PVC Sheathed Single Core Cables for Fixed Installations Double Insulated Power Cable

22kv Medium Voltage Underground XLPE Insulated Power Cable

Popular jinlingcable Products

6381y 450/750V Single Core Light PVC Sheathed DC Flexible Cable

Mv Aerial Bundled Conductor ABC Overhead Cables

Copper/Aluminum Conductor PE/XLPE/PVC Insulation Electric Power Twisted Overhead Service Drop ABC Cable

Nayby Aluminum Conductor Steel Tape Armoured Power Armor Cable

Nyby Single Core Underground Armoured Power Direct Burial Cables

600V 14 12 10 8 6 AWG Thw Copper Wire PVC Cable AWG Wire

Popular Medium Voltage Power Cables Products

Medium Voltage Aluminium Power Cables Na2xsy

Medium Voltage Copper Power Cables N2xsy Crosslinked PVC/XLPE Sheathed Copper/Aluminum Core Power Cable for Fire Retardant

Medium Voltage Copper Power Cables N2xsy

Popular Power Cable Products

PVC Insulated Fire Resistant Cable, Electric Power Cable, Instrument Cable

DIN Standard Copper Cable N2xy Power Cable

ASTM B232 ACSR Conductor Aluminium Cable Swan/Turkey/Sparrow/Kiwi

Mv-90, Copper Tape Shield Power Cable, 25 Kv, 3/C, Cu/XLPE/Cts/PVC (ICEA S-93-639/NEMA WC71/UL 1072)

4 Core 25mm 70mm 120mm 150mm XLPE Armoured Underground Power Cable

XLPE Insulated Low Voltage 4 Core Aluminum Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION