0.6/1kv Yjv N2xy XLPE / PVC Insulated Copper/Aluminium Conductor Power Cable
0.6/1kv Yjv N2xy XLPE / PVC Insulated Copper/Aluminium Conductor Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Standard:
IEC60502, BS6346, VDE, AS/NZS, UL, etc
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
|
TYPE |
NAME |
Main Application |
|
|
CU core |
AL core |
||
|
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
|
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
|
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
|
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
Specification
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
| 1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
| 1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
| 1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
| 1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
| 1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
| 1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
| 1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
| 1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
| 1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
| 1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
| 1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
| 1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
| 1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
| 1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
| 1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
| 2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
| 2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
| 2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
| 2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
| 2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
| 2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
| 2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
| 2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
| 2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
| 2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
| 2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
| 2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
| 2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
| 2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
| 2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
| 2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
| 3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
| 3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
| 3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
| 3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
| 3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
| 3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
| 3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
| 3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
| 3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
| 3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
| 3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
| 3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
| 3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
| 3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
| 3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
| 3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
| mm² | mm | mm | mm | mm | mm | mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
| 3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
| 3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
| 3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
| 3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
| 3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
| 3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
| 3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
| 3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
| 3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
| 3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
| 4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
| 4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
| 4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
| 4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
| 4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
| 4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
| 4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
| 4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
| 4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
| 4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
| 4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
| 4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
| 4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
| 4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
| 4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
| 4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
1). Rated Voltage, No. of Core and Range of Sectional Area
| Rated voltage (kv) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
| 2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | – | 26/35 | |
| 1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
| 2 Core | 1.5-185 | 25-185 | |||||||
| 3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
| 4 Core | 2.5-400 | 25-400 | |||||||
| 5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
| Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
| Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
| Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
| Rate voltage Uo (kv) Item |
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
| Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
| Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
| Partial discharge test | Test voltage | – | – | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
| Discharge capacity | – | – | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
About US
People’s Cable Group Co., Ltd. Was founded in 2007, with good transport facilities which adjacent to the 310 national highway-Lian Huo highway. Our company had 2 factories(Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than 10 million USD, with 630 staff members, 65 of which are professional and technical experts.
Our mainly products as follow:
1–pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2–pvc and xlpe insulated power cable with or without armor upto 35kv.
3–rubber cable like welding cable, mine cable, EPR cable and so on.
4–aerial bundled cable(ABC cable) up to 10kv.
5–bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Customer Vist
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Certification
As top rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
FAQ:
I didn’t find the cable which I need in this page?
If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.
Are you a trading company or manufacture?
RMJT is a professional manufacturer in Henan, China.
What is the MOQ?
Mostly we sell from stock for normal items, you can buy any quantity unless its customed-made.
Can you offer me a free sample?
Yes, after price confirmation, you can require for samples to check our quality.sample is free but the freight charge should be paid.
How long get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days
How is your package?
Normally packed with coils and cartons, and wooden/steel wooden drums, other ways can be done according you.
How is the payment?
T/T, L/C is accepted.
What is the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
Contact US
Factory Add: No. 13th, Yongding Road, Gongyi, Zhengzhou city, Henan province, China.
Attn: Aaron Tang
Mobile:+86 13157107563
Fax:+86-371-55632830
Websites:renmincable.en.
renmincable.en.
We are China 0.6/1kv Yjv N2xy XLPE / PVC Insulated Copper/Aluminium Conductor Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Copper Conductor Power Cable Products
0.6/1 Kv Copper Conductor XLPE Insulation /Swa/PVC Sheath Electrical Power Cable
1.5mm 2.5mm Twin and Earth Wire Flat Three and Earth Cable Building Wire Power Cable
Electric Power Cables 35mm Aluminum Power Cable for Industrial Buildings
XLPE Electrical Cables Armoured Aluminum Power Building ASTM Standard Cable
Yjv Mv XLPE Insulation Swa Armoured Copper/Aluminum Conductor Power Cables
0.6/1kv Underground Power Transfer Cable Copper/Aluminum Conductor XLPE Insulated Power Cable Wire
Popular Power Cable Products
11kv Mv ABC Cable Aluminium 3 Core Type a (armoured) with SABS Certificate Cable
Copper Aluminum Conductor XLPE PVC Insulation 25mm 3 Core Steel Wire Armoured Swa Electrical Wire
XLPE Insulated PVC Electric Wire Power Cable for Construction
Bare Conductor BS Standard ACSR Aluminum Conductor Caracal Panther Jaguar Zebra
3.3kv to 45kv Medium Voltage Power Cable Mv90 Mv105 Mv Cable
Low Voltage PE Insulation Triplex Service Drop Electrical Overhead Cable
Popular renmincable Products
Overhead Bare Aluminum Alloy Conductor AAAC Cable
Single Core Armoured Cable Electric Copper Power Cable
Overhead XLPE Insulated Quadruplex Service Drop ABC Cable
Yjlv Aluminum Conductor 4 Core XLPE Insulated Power Cable 0.6/1kv
LV Low Voltage XLPE Insulated Electrical Power Cable Manufacturer
Popular XLPE Insulated Cable Products
Medium Voltage XLPE Insulated Steel Wire Armoured (SWA) Red Cable
Direct Manufacturer Supply XLPE Insulated Power Cable
2*16mm2 4*16mm2 Electric AAC/AAAC/ACSR Conductor Service Drop ABC Cable
XLPE Insulated ABC Cable 95mm2 Quadruplex
0.6/1kv 3X1.5mm2 PVC Electric Copper Tape Armoured Power Cable
0.6/1kv 4 Core XLPE Insulated Armored Copper Underground Electrical Cable
Tags: Copper Conductor Power Cable, Power Cable, renmincable, XLPE Insulated Cable