IEC 129: 1975: Alternating Current Disconnectors (Isolators) and Earthing Switches
IEC 60694: 2002: Common Specifications for High Voltage Switchgear and Controlgear
BS 729: Hot dip galvanized coating on iron and steel articles
IEC62271-102
Isolator (Disconnector) – a mechanical switching device which provides, in the open position, an isolating distance in accordance with Electrical Safety requirements.
SERVICE CONDITIONS
The isolator shall be suitable for continuous operation outdoors in tropical areas at altitudes of up to 2200m above sea level, humidities of up to 90%, average ambient temperature of +30º C with a minimum of -1º C and a maximum of +40º C and heavy saline conditions along the coast.
4.2. DESIGN AND CONSTRUCTION
4.2. 1 The Isolator, Solid Link shall be designed and constructed in accordance with IEC 129 and IEC 60694.
4.2. 2 The isolating link shall be of the vertical opening, designed for single phase manual operation. It shall be easily removed and replaced by using a portable operating rod.
4.2. 3 The isolating link shall incorporate double porcelain insulators to suit voltage requirements and mounted on hot dipped galvanised steel under base suitable for vertical mounting.
4.2. 4 The isolating link shall be arranged so that each unit is mounted independently on an angle bracket. It shall be supplied complete with the angle bracket and accessories suitable for mounting on ‘U’ type steel channel. The drawings to be submitted shall indicate all the applicable mounting positions.
4.2. 5 The isolator shall be designed such that in fully open position, it shall provide adequate electrical isolation between the contacts on each phase. It shall conform to the requirement as single point isolation for safety.
4.2. 6 All steel parts shall be hot dip galvanized to BS 729. The minimum coating of galvanizing required is 80 microns.
4.2. 7 The solid link shall be removable from the mounting by use of operating rod.
4.2. 8 All current carrying parts of the isolator shall be made of high conductivity material.
4.2. 9 The isolator shall be fitted with clamp connectors for Aluminium (ACSR) conductor of Aluminium (ACSR)conductor of up to 18.2mm diameter.
The rating of the complete isolator shall be as follows: –
Rated voltage
36 kV
Rated frequency
50 Hz
Rated lightning impulse withstand voltage
200 kV
Rated power frequency withstand voltage, dry
95 kV
Rated normal current
400 Amps
Rated short time withstand current for 3 sec, min.
18.0 kA
Minimum creepage distance of insulators
900 mm
We are China 11kv Air Break Switch, Disconnecting Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Disconnector Switch Products
33kv 630A Load Isolators High Voltage
Overhead 33kv Mv Gang Opearated 630A ABS Air Break Switches
Outdoor Single Pole Fused Recloser by-Pass Switches 11kv 900A
(GN19-12) Indoor Disconnect Switch
Electroscope (with aluminum box and sail bag)
Iacm 24kv 50A 3 Phase Outdoor Switch Disconnector
Popular jgtrade1 Products
Suspension Clamps (Hang-down Type)
Best Price 11kv 200A Ceramic Types Drop out Fuses Cutout/Cut out Fuse
Fuse Cutout, Drop out Fuses 27kv 100A
Popular Rotary Switch Products
Seccionador Tripolar, Break Isolator, Substation
IEC Product High Voltage Disconnect Switch Disconnector
T-Connectors Type Tl, with Jump Clamp
Outdoor Low Voltage Disconnect AC Disconnector Electrical Vertical Opening
34.5/0.433kv, 500kVA Ground Mounted Distribution Transformer
Popular Switch Disconnector Products
11kv to 33kv Power Distribution Equipment Ceramic Dropout Fuse Types
Cheap Price Drop out Types of High Voltage Fuses
Preformed Guy Grip 7/8 Swg Dead Ends
15kv Single Pole Combination by-Pass and Disconnect Switch
OEM Accept High Voltage Outdoor Disconnect Switch Disconnector
Outdoor Single Pole Fused Recloser by-Pass Switches 11kv
Tags: Disconnector Switch, jgtrade1, Rotary Switch, Switch Disconnector