50mm2 XLPE Insulated Aluminum Conductor Power Cable
50mm2 XLPE Insulated Aluminum Conductor Power Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Standard:
IEC60502, BS6346, VDE, AS/NZS, UL, etc
The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 – 26/35
Application:
XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
|
TYPE |
NAME |
Main Application |
|
|
CU core |
AL core |
||
|
YJV/YJY |
YJLV/YJLY |
XLPE insulated,PVC/PE sheathed power cable |
For laying indoor ,tunnel,canal and underground. |
|
YJV22/YJV23 |
YJLV22/YJLV23 |
XLPE insulated,steel tape armored, |
For laying indoor ,tunnel,canal and underground. |
|
YJV32/YJV33 |
YJLV32/YJLV33 |
XLPE insulated,thin steel wire armored, |
For laying in shaft,water underground will large difference of level. |
|
YJV42/YJV43 |
YJLV42/YJLV43 |
XLPE insulated,thick steel wire armored, |
For laying in water and seabed. |
Number of cores:
1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.
Nominal Section
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
Features:
1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground.
Specification
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Alum Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 1×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 10.9 |
| 1×6 | 2.8 | 0.7 | 1 | 0.8 | 1.8 | 11.4 |
| 1×10 | 3.6 | 0.7 | 1 | 0.8 | 1.8 | 12.2 |
| 1×16 | 4.5 | 0.7 | 1 | 0.8 | 1.8 | 13.1 |
| 1×25 | 5.6 | 0.9 | 1 | 0.8 | 1.8 | 14.6 |
| 1×35 | 6.7 | 0.9 | 1 | 1.25 | 1.8 | 16.6 |
| 1×50 | 8 | 1 | 1 | 1.25 | 1.8 | 18.1 |
| 1×70 | 9.4 | 1.1 | 1 | 1.25 | 1.8 | 19.7 |
| 1×95 | 11 | 1.1 | 1 | 1.6 | 1.8 | 22 |
| 1×120 | 12.4 | 1.2 | 1 | 1.6 | 1.8 | 23.6 |
| 1×150 | 13.8 | 1.4 | 1 | 1.6 | 1.8 | 25.4 |
| 1×185 | 15.3 | 1.6 | 1 | 1.6 | 1.8 | 27.4 |
| 1×240 | 17.5 | 1.7 | 1 | 1.6 | 1.9 | 29.9 |
| 1×300 | 19.5 | 1.8 | 1 | 2 | 2 | 33.1 |
| 1×400 | 22.6 | 2 | 1.2 | 2 | 2.2 | 37.3 |
| 1×500 | 25.2 | 2.2 | 1.2 | 2 | 2.3 | 40.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 2×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 12.8 |
| 2×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 13.6 |
| 2×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 14.6 |
| 2×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 16.5 |
| 2×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.1 |
| 2×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 19.9 |
| 2×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 23.6 |
| 2×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 25.8 |
| 2×50 | 8 | 1 | 1 | 1.6 | 1.9 | 29 |
| 2×70 | 9.4 | 1.1 | 1 | 2 | 2 .3 | 3.2 |
| 2×95 | 11 | 1.1 | 1.2 | 2.1 | 3 | 7.1 |
| 2×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 40.5 |
| 2×150 | 13.8 | 1.4 | 1.2 | 2.5 | 2.4 | 45.4 |
| 2×185 | 15.3 | 1.6 | 1.4 | 2.5 | 20.6 | 49.9 |
| 2×240 | 17.5 | 1.7 | 1.4 | 2.5 | 20.7 | 55.1 |
| 2×300 | 19.5 | 1.8 | 1.6 | 2.5 | 20.9 | 60.2 |
| 2×400 | 22.6 | 2 | 1.6 | 2.5 | 30.1 | 67.7 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 3×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 13.2 |
| 3×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.1 |
| 3×4 | 2.3 | 0.7 | 1 | 0.8 | 1.8 | 15.2 |
| 3×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 17.1 |
| 3×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 18.9 |
| 3×16 | 4.5 | 0.7 | 1 | 1.25 | 1.8 | 20.8 |
| 3×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 24.7 |
| 3×35 | 6.7 | 0.9 | 1 | 1.6 | 1.8 | 27.2 |
| 3×50 | 8 | 1 | 1 | 1.6 | 1.9 | 30.6 |
| 3×70 | 9.4 | 1.1 | 1 | 2 | 2.1 | 35.2 |
| 3×95 | 11 | 1.1 | 1.2 | 2 | 2.2 | 39.3 |
| 3×120 | 12.4 | 1.2 | 1.2 | 2 | 2.3 | 43 |
| 3×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.5 | 48.6 |
| 3×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.7 | 53 |
| 3×240 | 17.5 | 1.7 | 1.4 | 2.5 | 2.8 | 58.5 |
| 3×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3 | 64 |
| 3×400 | 22.6 | 2 | 1.6 | 3.15 | 3.3 | 73.5 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
||
| mm² | mm | mm | mm | mm | mm | mm | mm | mm |
| 3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1 | 1.6 | 1.8 | 22.7 |
| 3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.8 | 26.5 |
| 3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1 | 1.6 | 1.9 | 29 |
| 3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1 | 1.6 | 2.1 | 33 |
| 3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 1.2 | 2 | 2.2 | 38 |
| 3x 95/50 | 11 | 8 | 1.1 | 1 | 1.2 | 2 | 2.3 | 42.4 |
| 3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 1.2 | 2 | 2.5 | 48 |
| 3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 1.4 | 2.5 | 2.7 | 52 |
| 3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 1.4 | 2.5 | 2.8 | 57.2 |
| 3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 1.6 | 2.5 | 3.1 | 64 |
| 3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 1.6 | 2.5 | 3.2 | 69.8 |
| Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
| mm² | mm | mm | mm | mm | mm | mm |
| 4×1.5 | 1.4 | 0.7 | 1 | 0.8 | 1.8 | 14 |
| 4×2.5 | 1.8 | 0.7 | 1 | 0.8 | 1.8 | 14.9 |
| 4×4 | 2.3 | 0.7 | 1 | 1.25 | 1.8 | 17 |
| 4×6 | 2.8 | 0.7 | 1 | 1.25 | 1.8 | 18.2 |
| 4×10 | 3.6 | 0.7 | 1 | 1.25 | 1.8 | 20.2 |
| 4×16 | 4.5 | 0.7 | 1 | 1.6 | 1.8 | 23 |
| 4×25 | 5.6 | 0.9 | 1 | 1.6 | 1.8 | 26.7 |
| 4×35 | 6.7 | 0.9 | 1 | 1.6 | 1.9 | 29.5 |
| 4×50 | 8 | 1 | 1 | 2 | 2.1 | 34.2 |
| 4×70 | 9.4 | 1.1 | 1.2 | 2 | 2.2 | 38.8 |
| 4×95 | 11 | 1.1 | 1.2 | 2 | 2.3 | 42.9 |
| 4×120 | 12.4 | 1.2 | 1.4 | 2.5 | 2.5 | 48.6 |
| 4×150 | 13.8 | 1.4 | 1.4 | 2.5 | 2.7 | 53.2 |
| 4×185 | 15.3 | 1.6 | 1.4 | 2.5 | 2.8 | 58.1 |
| 4×240 | 17.5 | 1.7 | 1.6 | 2.5 | 3.1 | 64.8 |
| 4×300 | 19.5 | 1.8 | 1.6 | 2.5 | 3.2 | 70.4 |
| 4×400 | 22.6 | 2 | 1.8 | 3.15 | 3.6 | 81.3 |
1). Rated Voltage, No. of Core and Range of Sectional Area
| Rated voltage (kv) Sectional area (mm2) No. of core |
1st class | 0.6/1 | 1.8/3 | 3.6/6 | 6/10 | 8.7/15 | 12/20 | 18/30 | 21/35 |
| 2nd class | 1/1 | 3/3 | 6/6 | 8.7/10 | 12/15 | 18/20 | – | 26/35 | |
| 1 Core | 1.5-800 | 25-800 | 25-1200 | 25-1200 | 35-1200 | 50-1200 | 50-1200 | 50-1200 | |
| 2 Core | 1.5-185 | 25-185 | |||||||
| 3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
| 4 Core | 2.5-400 | 25-400 | |||||||
| 5 Core | 2.5-400 | 25-400 |
2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
| Nominal section area (mm2) | 1.5 | 2.5 | 4 | 6 | 10 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 | 240 | 300 | 400 | 500 | 630 | 800 |
| Copper core | 12.1 | 7.41 | 4.61 | 3.08 | 1.83 | 1.15 | 0.727 | 0.524 | 0.387 | 0.268 | 0.193 | 0.153 | 0.124 | 0.099 | 0.0754 | 0.0601 | 0.047 | 0.0366 | 0.0283 | 0.0221 |
| Aluminum core | 18.1 | 12.1 | 7.41 | 4.61 | 3.08 | 1.91 | 1.2 | 0.868 | 0.641 | 0.443 | 0.32 | 0.253 | 0.206 | 0.164 | 0.125 | 0.1 | 0.778 | 0.0605 | 0.0469 | 0.0367 |
3). Voltage Test and Partial Discharge Test
| Rate voltage Uo (kv) Item |
0.6/1 | 1.8/3 | 3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | |
| Voltage | Test voltage | 3.5 | 6.5 | 12.5 | 21 | 30.5 | 42 | 63 | 73.5 | 91 |
| Test time | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | |
| Partial discharge test | Test voltage | – | – | 6.2 | 10.4 | 15.1 | 20.8 | 31.1 | 36.3 | 45 |
| Discharge capacity | – | – | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
Packaging
Packing Details : Packing in wooden drum, iron-wooden drum or as customer’s requirement.
Delivery Details : 15-25 days after place an order.
About US
People’s Cable Group Co., Ltd. Was founded in 2007, with good transport facilities which adjacent to the 310 national highway-Lian Huo highway. Our company had 2 factories(Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters. The real capital assets more than 10 million USD, with 630 staff members, 65 of which are professional and technical experts.
Our mainly products as follow:
1–pvc insulated electric wire whatever copper conductor,aluminum conductor, CCA(copper clad aluminum), CCS(copper clad steel).
2–pvc and xlpe insulated power cable with or without armor upto 35kv.
3–rubber cable like welding cable, mine cable, EPR cable and so on.
4–aerial bundled cable(ABC cable) up to 10kv.
5–bare conductor like AAC, AAAC, ACSR, ACAR, ACSR/AW, aluminum clad steel wire, galvanized steel wire, PC steel wire and so on.
Customer Vist
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!
Certification
As top rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
FAQ:
If you didn’t find the species of cables you need, please contact us directly, we will reply you quickly.
Are you a trading company or manufacture?
RMJT is a professional manufacturer in Henan, China.
What is the MOQ?
Mostly we sell from stock for normal items, you can buy any quantity unless its customed-made.
Can you offer me a free sample?
Yes, after price confirmation, you can require for samples to check our quality.sample is free but the freight charge should be paid.
How long get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~5 days
How is your package?
Normally packed with coils and cartons, and wooden/steel wooden drums, other ways can be done according you.
How is the payment?
T/T, L/C is accepted.
What is the lead time for mass production?
Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within a week. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.
We are China 50mm2 XLPE Insulated Aluminum Conductor Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aluminum Conductor Cable Products
Fire Resistant ABC Aluminum Cable 600V 1000V
Self Support Aerial Cable Overhead
Plum Aluminum Conductor Overhead XLPE Insulated ABC Cable
Middle Voltage 20kv Aluminum Conductor XLPE Insulated Steel Tape Armored Power Cable
Single Core XLPE Insulated Copper Wire Shield 11kv Aluminum Power Cable
Na2xy Aluminum Conductor Cable XLPE Insulated PVC Jacket Cable
Popular Power Cable Products
Al/XLPE/Cts/PVC/Sts/PVC, Power Cable, 12/20 (24) Kv, 3/C (IEC 60502-2)
Triplex Secondary Urd, Urd Cable, 600 V, Al/XLPE (ANSI/ICEA S-105-692)
PVC Sheathed Yjv Yjv22 120mm2 Cable Power XLPE Insulated 0.6/1kv Cable
En 60881 Yslycy 0.6/1kv Black Flexible Stranded Bare Copper PVC Insulated Cable
UL Approved PVC Insulated Nylon Sheathed 12AWG Thhn Electrical Cable Wire
Popular renmincable Products
Low Voltage Covered Line Aluminum Wire
Low Voltage ABC Cable (Aerial Bundled Conductors)
Overhead Compact AAAC Conductor All Aluminum Alloy Conductorfor Power Transmission
High Voltage 300mm2 Aluminum Conductor XLPE Insulated Power Cable
Popular XLPE Cable Products
Low Voltage Power Cable 3X6+1X6 mm2 Flame Retardant PVC
Armored XLPE Power Cable / Steel Wire
ATA Armour Cable 11kV 12kV 33kV 400 Sqmm 630 Sqmm Single Copper Cable for Nepal
4 Core 70mm2 95mm2 240mm2 Nyy Power Cable
LV Cable Al/XLPE/PVC IRAM 2178 Standard 3X150/70mm2 0.6/1kV
XLPE /PVC Insulated Electric Power Cable
Tags: Aluminum Conductor Cable, Power Cable, renmincable, XLPE Cable