Substation Surge Protective Lightning Arrester for Lightning Protection System
Substation Surge Protective Lightning Arrester for Lightning Protection System image
Get Latest Price Request a quote
Quick Details
Product Details
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
2. Surge Arrester Technical Parameters:
| Type | YH5W5-15/33 | ||
| Rated voltage———kV | 15 | 4/10μS High current impulse kA | 65 |
| MOCV —————-kV | 12.7 | Lightning impulse withstand kV | 95 |
| Nominal Current——-kV | 5 | Power frequency voltage withstand(dry/wet)kV | 28 |
| Residual voltage of steep impulse—-at 5kA(kV) | 43.5 | 0.1S TOV————–kV | 18 |
| 8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 40 | 1S TOV—————-kV | 17.25 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 10S TOV—————kV | 16.5 |
| 1mA D.C reference voltage (kV) | 21.2 | 1200S TOV————-kV | 15 |
| Line discharge level | 1 | Creepage distance —-mm | 500 |
| 2mS long duration impulse current A | 250 | Material employed in series non-linear resistor | Zinc Oxide |
3. Surge Arrester Working Condition:
| Environment temperature: -40–+40 degree |
| altitude:<1000m |
| 48HZ<Rated frequency<62HZ |
| Power frequency voltage should not be more than continuous running voltage |
| Max wind speed should be less than 35m/s |
| Earthquake intensity should be less than 7 degree |
| If used in contamination area, should be noted in advance. |
4. Other Surge Arrester
Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. We are one of the recommended model companies for national power grid of China. Our company is the professional manufacturer of 0.22KV-500KV metal oxide surge arresters, Zinc oxide varistors, 10-220KV outdoor disconnectors, earthing switches, composite insulators and fuse cutouts.
Yongde sticks to the quality policy of "being the technical forerunner, supreme in quality, supremacy of customers, and innovative progressing", so that our products and services successfully satisfy our users. We warmly welcome friends and customers from at home and abroad to contact us for exchange and corporation. We also welcome the feedback from our users.
Production Lead Time & Quality Guarantee:
1. Sample deliery time is about 2-3 days;
big order quantity is about 30-35 days after we receive 30%~50% deposit from you.
Generally, it takes 4 working days by DHL/UPS, and 7-10 days by EMS.
2. 12 months’ warranty period. 20 years’ quality guarantee period
With ISO9001:2008approvals.
Customer Services:
Our salesmen will reply your inquiry within 24 hours. Any order is welcome. If you like to be our agent in your country, we can give you any support on the technique & other aspects.
We are China Substation Surge Protective Lightning Arrester for Lightning Protection System manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
252kv Centre Berak Two Column Ceramic Insulator Disconnector Switch
Latest Promotion Price 132kv 10ka Power Station Type Surge Arresters
High Voltage 33kv Outdoor Lightning Arrester/Lighting Surge Protector in Station
132kv Hv Silicon Rubber Surge Arresters in Hangzhou
OEM Electrical Power Systems 230kv 10ka Polymeric Housed Lightning Arrester
IEC60099-4 132kv High Voltage Metal-Oxide Lightning Surge Arrester for Substaion
Popular Lightning Protector Products
Supplies Electrical Equipment High Voltage Polymeric Porcelain Surge Arrester Discharge
Moa/Metal Oxide Lightning Arrester /Metal Oxide Surge Arrester
110kv Metal Oxide Lightning Arrester
Low Voltage Station Type Surge Protection Surge Arrester 220V
Distribution Equipment 132kv High Voltage Metal-Oxide Polymeric Ceramic Surge Arrester
Substation 33kv Types of Lightning Arrester with Disconnector
Popular Surge Arrester Products
35kv Porcelain Housed Surge Arrester
Gapless Composite 11kv Lightning Arrestor 5ka Surge Arrester
Xirui Factory Bulk 33kv/10ka Polymeric Surge Arrester
Hangzhou Gapless Type Zinc Oxide Lightning Protection Arrester 30kv
18kv High Voltage Electrical Surge Arrester for Transmission Line
Popular Surge Protector Products
Wholesale Price High Quality Transmission Line 18kv Metal-Oxide Surge Arrester
24kv Polymer ZnO Lightning Arrester/Surge Arrester
Surge Protector Gray Surge Arrester
High Voltage Composite Polymer Surge Arrester 24kv 10ka
Silicon Rubber Lighting Arrester 3kv/Professional Manufactory
220 Kv Transmission Composite Zinc Oxide Surge Arrester Lightning
Tags: hzyddq, Lightning Protector, Surge Arrester, Surge Protector