High Voltage Equipments 220kv Polymer Lightning Arrester

China 
                        High Voltage Equipments 220kv Polymer Lightning Arrester
                      manufacture and supplier

High Voltage Equipments 220kv Polymer Lightning Arrester image

Get Latest Price Request a quote

Quick Details

High Voltage Equipments 220kv Polymer Lightning Arrester

Y10W5-220

Kema Type Test Report

High Voltage Equipments

Light Duty, Heavy Duty

IEC60099-4

Silicone, Polymer, Porcelain, Ceramic

Shipped in 30 Days After Payment

Over-Voltage Protection

Bracket,Insulating Cap,Cooper Lead,Insulator,Hoop

Brown, Gray

Power Distribution System

YONGDE

Wooden Case

Zhejiang, China (Mainland)

853310000

Product Details

High Voltage Equipments 220kV Polymer Lightning Arrester

specification

1. Lightning Arrester for 35~220kv alternating system 

    Main features:

  • It adopts double sealing structure, the core encapsulates by molded silicone rubber which completely solves the sealing problem of porcelain housed products.
  • It has a two-way pressure release structure.
  • Its core component ZnO varistor has good pressure ratio, consistency, large flow capacity and high reliability.
  • E creepage distance of porcelain housed products is wide which is suitable for IV level heavy pollution areas.

 

2. Technical Parameters

Type: Y10W5-198/499    
Rated voltage———kV 198 4/10μS High current impulse kA  100
MCOV  —————-kV 158 Lightning impulse withstand kV 950
Nominal Current——-kA 10 Power frequency voltage withstand(dry/wet)kV 395
Residual voltage of steep impulse—-at 5kA(kV) 618 0.1S TOV————–kV 237.6
8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) 514 1S TOV—————-kV 227.7
Residual voltage of switching impulse current kV (peak value)—-at 1kA  (kV) 402 10S TOV—————kV 217.8
1mA D.C reference voltage (kV) 288 1200S TOV————-kV 198
Line discharge level 2 Creepage distance —-mm 7812
2mS long duration impulse current A 800 Material employed in series non-linear resistor Zinc Oxide

3. Lightning Arrester Working Condition: 

Environment temperature: -40–+40 degree
altitude:<1000m
48HZ<Rated frequency<62HZ
Power frequency voltage should not be more than continuous running voltage
Max wind speed should be less than 35m/s
Earthquake intensity should be less than 7 degree
If used in contamination area, should be noted in advance.

 

 

4. MOA Production Process:

 

 

 

We are China High Voltage Equipments 220kv Polymer Lightning Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Arrester Products

Sbstation Surge Protector 18kv/Ploymer Lightning Arrester

Supply Oxide Gapless Lightning 11kv Polymeric Surge Arrester

Xirui New-Designed 10kv Polymer Lightning Arrester/Surge Arrester

Lightning Arrester, Polymer Metal Oxide Surge Arrester 3-132kv, 10ka

15kv Polymeric Surge Arrester for Substation

Metal Oxide Gapless Surge Arrester

Popular hzyddq Products

High Quality Surge Arrester Protector

Polymer Housed Transformer Protector Arrestor Lightning

500kv Outdoor Substation Ceramic Housing Zinc-Oxide Surge Arrester Without Gaps

RJ45 Network Lightning Surge Protector

Medium-Voltage Sort of Surge Arrester/Low Voltage Protector

500kv Substation 9kv to 33kv Polymer Composite Type Surge Diverter

Popular Lightning Arrester Products

Yh10W-216.216kv 10ka Surge Arrester

Surge Protective Device Surge Suppressor

Bolt and Nut M20X450

Lightning Protector Surge

Hangzhou OEM Lightning Protection Systems 30-220kv ZnO Surge Arrestor

3kv~220kv Surge Arrester Lighting Arrester

Popular Protectors Products

Power Equipment 6-9kv Electrical Surge Arrester Low Voltage

11kv Silicon D Fuse, Fuse Cutout, Drop-Outfuse, Fuse Cut out, Fuse Cutout

Fuse Cutout, Dropout Fuse, Porcelain & Polymer Isolator Possible, 12kv, 24kv, 36kv

35kv Porcelain Housed Surge Arrester

RW2-15 High Voltage Dropout Fuse Cutout

Lighting Protector Low Voltage Rated Voltage 12kv/Hangzhou Arrestor

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION