Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters
Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters image
Get Latest Price Request a quote
Quick Details
Product Details
0.28kV~500kV Surge Arresters’ Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column, with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops, the product can be applied to the complete cabinet installation, which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level in heavy pollution areas.
Technical Parameters:
| Type: |
Y5W5-108/259 |
||
| Rated voltage———kV | 108 | 4/10µS High current impulse kA | 100 |
| MCOV —————-kV | 86 | Lightning impulse withstand kV | 550 |
| Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 230 |
| Residual voltage of steep impulse—-at 5kA(kV) | 339 | 0.1S TOV————–kV | 129.6 |
| 8/20µS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 281 | 1S TOV—————-kV | 124.2 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | 220 | 10S TOV—————kV | 118.8 |
| 1mA D.C reference voltage (kV) | 157 | 1200S TOV————-kV | 108 |
| Line discharge level | 2 | Creepage distance —-mm | 3906 |
| 2mS long duration impulse current A | 600 | Material employed in series non-linear resistor | Zinc Oxide |
Working condition:
| Environment temperature: -40–+40 degree | |||||||
| altitude:<1000m | |||||||
| 48HZ<Rated frequency<62HZ | |||||||
| Power frequency voltage should not be more than continuous running voltage | |||||||
| Max wind speed should be less than 35m/s | |||||||
| Earthquake intensity should be less than 7 degree | |||||||
| If used in contamination area, should be noted in advance. |
Line discharge level from 1 to 5,
We are China Line Discharge Level 2 Substation Outdoor Ceramic Housing Arresters manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Brown Surge Protection Device Arrester
High Quality Transformer Composite Polymer Metal Oxide Surge Arrestor
Silicon Rubber Lighting Arrester 3kv/Professional Manufactory
Polymer Insulator Surge Arrester
Gw16 Hangzhou Outdoor Substation Semi Pantograph Vertical Operation Disconnector
AC System Ceramic Porcelain Gapless Metal-Oxide Lightning Surge Arrester
Popular Lightning Arrester Products
High -Voltage Isolate Switch 6kv 600A
Composite Surge Lighting Arrester Manufacturer
High Voltage Electric Silicone Porcelain Surge Arrester 36kv to 110kv
35kv Silicon Type Surge Arrester Cma1.5W-30/80
Hy10W-30, 30kv10ka Surge Arrester
Popular Surge Arrester Products
54kv High Voltage Surge Arrester for Distribution Line
Hy5wz 9kv Metal Oxide Lightning Arrester Surge Arrester
High Voltage Polymer Silicone Rubber Electrical Lightning Arrester
11kv Composite/Polymer Metal-Oxide Lightning Arrester Surge Arrester Without Gaps
Yh10W-13, Sharp Head 18kv 10ka Surge Arrester
Yh10W-48, Sharp Head 48kv 10ka Surge Arrester
Popular Surge Arresters Products
10ka Power Station Type Ceramic ZnO Surge Diverters with Silicone Housed
33kv Polymer Housed Lightning Arrester
Polymer Housed Zinc Oxide Lightning Surge Arrester
Metal Oxide Varistor for Surge Arrester
35kv-220kv Polymer Housed Zinc Oxide Surge Arrester
Electrical Product 30kv Surge Protective Device
Tags: hzyddq, Lightning Arrester, Surge Arrester, Surge Arresters