Top Selling Power Transmission Line Equipment MOA ZnO Lightning Arrester
Characteristics:
1. The Core column applied winding structure, Polymer Housed core pillar molded on the core column,
with almost no internal air gap, and outstanding sealing performance Simple in structure, small in size
and light in weight.
2. Polymer Housed with silicone rubber, explosion-proof ZnO varistor as the core component is large
in flow capacity.
3. International standard IEC 60099-4 and ANSI 62.22, and with high reliability. With fully insulated tops,
the product can be applied to the complete cabinet installation,
which can reduce the designing size of cabinet.
4. Products with detachment device can provide signals for quitting operation when failure occurs,
avoiding arrester explosion, and it is maintenance-free.
5. Polymer housed products with a six CTI level, creepage distance meets the requirements of IV level
in heavy pollution areas.
2. Surge Arrester Technical Parameters
| Type | YH5W5-33/88 | ||
| Rated voltage———kV | 33 | 4/10μS High current impulse kA | 65 |
| MCOV —————-kV | 27.5 | Lightning impulse withstand kV | 150 |
| Nominal Current——-kA | 5 | Power frequency voltage withstand(dry/wet)kV | 70 |
| Residual voltage of steep impulse—-at 5kA(kV) | 95 | 0.1S TOV————–kV | 39.6 |
| 8/20μS Residual voltage of lightning impulse current kV(Peak value)—–at 5kA(kV) | 88 | 1S TOV—————-kV | 37.95 |
| Residual voltage of switching impulse current kV (peak value)—-at 1kA (kV) | / | 10S TOV—————kV | 36.3 |
| 1mA D.C reference voltage (kV) | 46.7 | 1200S TOV————-kV | 33 |
| Line discharge level | 1 | Creepage distance —-mm | 1082 |
| 2mS long duration impulse current A | 250 | Material employed in series non-linear resistor | Zinc Oxide |
Working Condition:
- Environment temperature: -40–+40 degree
- altitude:<1000m
- 48HZ<Rated frequency<62HZ
- Power frequency voltage should not be more than continuous running voltage
- Max wind speed should be less than 35m/s
- Earthquake intensity should be less than 7 degree
- If used in contamination area, should be noted in advance.
We are China Top Selling Power Transmission Line Equipment Moa ZnO Lightning Arrester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular hzyddq Products
Hangzhou Low Voltage 110V 220V Surge Protector with Kema
Gray Brown Surge Protector Arrester
110kv Electrical Polymeric ZnO Surge Arrester with External Gaps
Silicone Housing Arrester Lightning for Over-Voltage Protection
MOV ZnO Resistor for Surge Arrestor
Surge Protective Device Surge Suppressor
Popular Lightning Arrester Products
Polymer Housed Gapless Surge Arrester From 3 Kv up to 36 Kv
Rated Voltage 132kv Rated Current 10ka Station Class Gapless Surge Diverter
Popular Surge Protection Products
Lightning Protection Surge Arrester
Factory Supply Lightning Surge Metal-Oxide Arrester
Low Cost 33-66kv Low Voltage Metal Oxide Surge Protective Device Arresters
High Voltage Substation Lightning Arresters
Factory Supply Metal-Oxide Surge Arrester
Rated Voltage 27kv Discharge Class 1 Lightning Arrester for Substation
Popular Surge Protective Device Products
33kv Metal Oxide Gapless Surge Arrester Station Class
66kv Metal Oxide Gapless Surge Arrester Station Class
Surge Arrester 18kv 5ka for Distribution Use
Transformer Type Medium Voltage Class1 24kv Surge Arrestor with Kema
Pararrayo EstaciÓ N Polimero De 60kv
Tags: hzyddq, Lightning Arrester, Surge Protection, Surge Protective Device