L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector
L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector image
Get Latest Price Request a quote
Quick Details
Product Details
Insulation piercing connector is mainly suitable for the connection of the overhead insulation conductor, branch connection and grounding protection, It is used for the voltage which is 20KV, 10KV and 1KV and below. Applicable for Al-Cu conductor, different diameter wire connection, and equal diameter wire butt, and is suitable for the transition of copper aluminum insulation conductor link.
Main function and features:
1.Easy installation,No need to strip the cable insulation cover,
2.Piercing connector,special nut and torque nut.To ensure good electrical connection without damage wires.
3. Resistance reduced by 30% Heat cycle curve is more stable.
4.Good Insulation,It passed the power frequency withstand voltage and underwater withstand voltage performance test without any special treatment.Sealing structure and with insulation grease.wetpoof,waterproof,anti-corrosion,extend the service life of insulated conductor and clamp.
| Type | Suitable wire(mm²) | |
| Main Line(mm²) | Branch line (mm²) |
|
| JJC-300/300 | 240~300 | 240~300 |
| JJC-240/240 | 150~240 | 150~240 |
| JJC-240/120 | 150~240 | 70~120 |
| JJC-240/50 | 150~240 | 16~50 |
| JJC-150/150 | 95~150 | 95~150 |
| JJC-150/70 | 95~150 | 35~70 |
| JJC-95/95 | 50~95 | 50~95 |
| JJC-95/50 | 50~95 | 10~50 |
| JJC-70/35 | 16~70 | 10~35 |
| JJC-95/10 | 16~95 | 1.5~10(Street Lamp Branch Line) |
| JJC-50/10 | 10~50 | 1.5~10 |
| JJCD-240~300 | 240~300 | Grounding Connector |
| JJCD-95~240 | 95~240 | Grounding Connector |
| JJCD-35~120 | 35~120 | Grounding Connector |
| JJCD-16~95 | 16~95 | Grounding Connector |
We are China L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular High Strengh Alloy Ipc Products
Jjc2 Insulating Piercing Connector Piercing Clamp
L&R High Strengh Alloy, Anti - UV Plastic Insulated Piercing Connector
L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector
L&R High Strength Alloy, Anti - UV Plastic Insulated Piercing Clamp
Popular Insulated Percing Connector Products
L&R High Strengh Alloy, Anti - UV Plastic Insulated Piercing Connector
Jjc2 Insulating Piercing Connector Piercing Clamp
Jjc2 Insulating Piercing Connector Piercing Clamp Ipc
L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector
Popular laurenceelectirc Products
LV 400A HRC Overhead Service Cut-out Transformer Fuse Cutout
Porcelain Stay Insulator for Lines
Sc 99.9 Percent Pute Copper Tube T2 and Coated with Tin Terminal Lugs
Dtl-1 Bimetallic Lug for Cable Terimination
11kv 120kn Tension Insulator, Polymer Housing
Popular Low Votage Ipc Connector Products
L&R High Strengh Alloy, Anti - UV Plastic Insulated Piercing Connector
Jjc2 Insulating Piercing Connector Piercing Clamp
L&R High Strength Anti UV Plastic Insulated Piercing Clamp
L&R 1kv Insulation Piercing Connector Ipc Power Cable Connector
Jjc2 Insulating Piercing Connector Piercing Clamp Ipc
L&R High Strength Alloy, Anti - UV Plastic Insulated Piercing Clamp
Tags: High Strengh Alloy Ipc, Insulated Percing Connector, laurenceelectirc, Low Votage Ipc Connector