Strain Clamps for Insulated Cable
Strain Clamps for Insulated Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Bolts and nuts,use for the transmission line and distribution line
| Product | D Bracket | ||||||
| Test Items | Test Content | Test Result | |||||
| Sample 1 |
Sample 2 |
Sample 3 |
Sample 4 |
Sample 5 |
Remarks | ||
| Visual Inspection | Crack | √ | √ | √ | √ | √ | 1) Passed Mark"√" 2) Not Passed Mark"×" Test Conclusion: |
| Stoma Trachoma | √ | √ | √ | √ | √ | ||
| Fins | √ | √ | √ | √ | √ | ||
| Burr | √ | √ | √ | √ | √ | ||
| Galvanizing thickness | μm | √ | √ | √ | √ | √ | 1) Passed Mark"√" 2) Not Passed Mark"×": Test Conclusion: |
| Mechanical Characteristics | Mechanical Load | √ | √ | √ | √ | √ | 1)Passed Mark"√" 2)Not Passed Mark"×" Test Conclusion: |
| Inspector | Date: 02. March,2011 Approved: | ||||||
TECHNICAL SPECIFICATION
1. SCOPE
This specification covers the design and construction of Tension of Tension Clamps to be used for the termination of aluminium-conductors at terminal poles and section poles.
The Clamps are suitable for used in Tropical zone, with a maximum ambient temperature of approximately 40ºC and a mean annual temperature of approximately 28ºC with high humidity and heavy rainfall.
2. STANDARD
this specification is make reference to and comply with the requirements of following standard:
BS 3288:1973 – Insulator and Conductor fitting for
Overhead Power Lines
BS 729 – Hot dip Galvanised
3. ELECTRICAL SYSTEM
The Clamps will be designed for use on a 3 phase,3 wires, 33/22/11/6.6kv,50 Hz, primary distribution system with the star-point of the source-end transformer earthed through an Earthing Resistor.
4. DESIGN AND CONSTRUCTION
The Clamps are manufactured from material which is not cause chemical corrosion when in constant contact with aluminium conductor. They are have a tensile strength that the breaking strength that are not less than the breaking strength of the conductors to be connected.
The Clamps are properly designed such that will not cause any unnecessary strain and abrasion on the surface of conductors.
5. SIZE OF CLAMPS
The Clamps aredesigned to accommodate the following sizes of Aluminium conductors:
a. 50mm2 Alu. Conductor
b. 100 – 150mm2 Alu. Conductor
6. MARKINGS
The Tension Clamps will be indelibly marked as Customer Requirment.
7. INSPECTION AND TESTS
For evaluation purposes, we will supply the following items to our cusotmer
a. A sample of the Tension Clamp complete with all accessories.
b. A copy of the test report on tests conducted in accordance to BS 3288 and BS 729
Material grade 300w steel to SANS 143
Finish: hot dip galvanized
With cut threads(cut before galvanizing)
Supplied complete with on Hex nut and one round flat washer
Thread pitch. 2.0(before galvanizing)
Washer outside diameter: 29.2-30.0mm bolt Hole 18.0-18 5mm, thickness:2.4-3.6mm
Materials Speciification:SANS 1431
Corrossion Specification:ISO1461
| DIMENSIONS | |
| A | 26.17mm-27.70mm |
| B | 23.16mm-24.00mm |
| C | 9.55mm-10.45mm |
| D | 15.30mm-16.70mm |
| E | 300mm |
| F | 150mm |
Recommended for You
Not exactly what you want?
Post Sourcing Request
Hot Searches
Standard Bolt
Fastener Nut Bolt
Bolt Screw
Hardware Nut
Stainless Bolt
We are China Strain Clamps for Insulated Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Bolt Products
ADSS Suspension Clamp Fitting Galvanized Steel Bolt on The Pole
Lag Screw for Pole Line Fitting
Pole Line Hardware Straight Angle Thimble Eye Anchor Rod Bolt
Pole Line Hardware Fitting Thimble Anchor Rod Pigtail Metal Clamp Eye Bolt
Popular Bolts and Nuts Products
Thimbles and M16X600mm Bolt &Nut
Lightning Protection Pillar Insulator (Piercing / Non-piercing)
Popular jgtrade1 Products
Load Break Switch Fuse Disconnector 45kv 200A
Fuse Cutout, Drop out Fuse 11-38kv
Flexible Terminal Connectors for Tubular Bus-Bar Type Mds, Group C
Aluminum Pg Clamp / Parallel Groove Clamp / Electrical Wire Clamp
Yh10W-100, 100kv 10ka Surge Arrester
Popular Screw Products
Lightning Protection Pillar Insulator (Piercing / Non-piercing)
Terminal Connectors Bolted Type, Type SL, Group a
Strain Clamps for Aacsr Hydraulic Compression Type
Strain Clamps for Lhaj Hydraulic Compression Type
Suspension Clamps for Twin Jumper Conductors
Tags: Bolt, Bolts and Nuts, jgtrade1, Screw