36kv 5kn Polymer Line Horizontal Post Insulator
36kv 5kn Polymer Line Horizontal Post Insulator image
Get Latest Price Request a quote
Basic Info.
Product Description
Composite Line Post Insulator
General
1.Ratings : up to 36kV.
2.Application : for lines suspending and insulation of power transmission & distribution system.
3.Standard: IEC 61109:2008,IEC 61952:2003,ANSI,etc.
Features:
Secure and reliable operation on high mechanical strength. Compact design and light in weight which is convenient for transportation. Good anti-vibration capability. Good anti-moisture capability. Good electric performances Strong anti-pollution falshover ability. High anti-aging performances which is perfect for utilization under conditions of high altitude. Easy for maintenance.
Product range:
Long rod Composite insulators up to 500kV.
Pin Composite insulator up to 36kV.
Post Composite insulator up to 252kV.
Line post Composite insulator up to 36kV.
Technology characteristics:
1)The silicone rubber housing taken shape by whole injection has good hydrophobicity, drophobicity migration and soil resistance, as well as excellent electrical insulation roperties and aging resistance, which could prevent effectively those accidents of pollution flashovers so as to ensure the safe running of high voltage transmission lines.
2)The modified ECR fiberglass reinforced epoxy resin rod is used as it has good resistance to high temperature, stress corrosion &acid attack, as well as fine damping action, high tensile strength( >1200Mpa ) and resistance to creep and fatigue failure, which effectively ensure the internal insulation quality and mechanical strength of insulators.
3)End fittings are crimped onto fiberglass rod with voice-operated displacement type crimper , The insulators with this crimping technique have high mechanical strength and small dispersion.
4)The connection location between end fittings & rods is fused with sheds housing by the overall high tempera- ture vulcanized silicone rubber injection molding as it could minimize the interface.
5)The internal radial multi-seal structure effectively guarantees a long-term reliability of seal around the connection between end fittings & rods.
Note:
1 Applicable stardand:IEC,ANSI,GB and other international standard
2 Normal colour of the composite insulator:red,gray and white.
3 Special design according customer’s requirement.
Working Condition
1.Ambient air temperature: -50ºC ~+50ºC
3.Altitude : <=3000m
3.Frequency:<=100Hz
| Main Technical Parameter | |||||||
| Model | Rated voltage (KV) | Specified mechanical load(kN) | Spacing H (mm) | Arcing distance (>mm) | Minimum creepage distance (>=mm) | Lightening impulse residual voltage under nominal discharge current (<=KVp) | Wet power frequency Withstand voltage(>=kVr.m.s.) |
| FPS-12/5 | 12 | 5 | 510 | 215 | 450 | 100 | 45 |
| FPS-12/10 | 12 | 10 | 540 | 215 | 400 | 100 | 45 |
| FPS-24/5 | 24 | 5 | 555 | 240 | 480 | 120 | 50 |
| FPS-36/5 | 36 | 5 | 635 | 325 | 1015 | 180 | 75 |
| FPS-36/10 | 36 | 10 | 675 | 350 | 1000 | 180 | 75 |
We are China 36kv 5kn Polymer Line Horizontal Post Insulator manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 36kv Horizontal Post Insulator Products
36kv Composite Line Horizontal Post Insulator for Distribution Line
36kv 5kn Polymer Line Horizontal Post Insulator for Distribution Line
36kv 10kn Polymer Line Horizontal Post Insulator for Distribution Line
36kv 10kn Polymer Line Horizontal Post Insulator
36kv Polymer Line Horizontal Post Insulator for Distribution Line
Popular 36kv Polymer Insulator Products
36kv 10kn Polymer Line Horizontal Post Insulator for Distribution Line
36kv High Voltage Polymer Insulator for Substation
36kv Silicone Rubber Polymer Insulator for Support Wire
12kv Silicone Rubber Polymer Insulator for Support Wire
36kv High Quality Polymer Insulator for Substation
36kv 5kn Polymer Line Horizontal Post Insulator for Distribution Line
Popular 36kv Polymer Post Insulator Products
36kv 5kn Polymer Line Horizontal Post Insulator for Distribution Line
36kv 10kn Polymer Line Horizontal Post Insulator for Distribution Line
36kv Polymer Line Horizontal Post Insulator for Distribution Line
36kv 10kn Polymer Line Horizontal Post Insulator
Popular people Products
6kv High Quality Surge Arrester for Distribution Line
Tension Clamps Four Core Collecting Dead End Clamp
Polymer Housed Metal Oxide Lightning Arrester Without Gaps
Polymeric Suspension Long Rod Insulator 145kv 120kn
11kv High Quality Breaking Overcurrent Fuse Cutout
18kv High Voltage Polymer Insulator for Transmission
Tags: 36kv Horizontal Post Insulator, 36kv Polymer Insulator, 36kv Polymer Post Insulator, people