100kv AC and DC High Voltage Withstand Voltage Tester
100kv AC and DC High Voltage Withstand Voltage Tester image
Get Latest Price Request a quote
Basic Info.
Product Description
Cpmposites insulator,All nsulators are manufactured in accordance
to IEC 61952. Quality processes are implemented
as per ISO 9001:2000.
| Item description | 11 kV Silicone composite Pin insulator requirements |
| Type | Silicone composed pin insulator complete with spindle, nut and washer |
| Nominal Voltage (kV) | 11 |
| Highest System Voltage (kV) | 12 |
| Min Nominal Creepage Distance ( mm ) |
280 |
| Min failing load (kN)-Mechanical test |
10 |
| Power frequency withstand voltage (one minute) Wet (kV r.m.s) |
28 |
| Lightning impulse withstand voltage (kV) peak |
95 |
| Material of insulation | High Temperature Vulcanised silicone rubber |
| Spindle diameter (mm) | 20 mm |
| Previous Type Test Certificate/results/report including ageing test at 5000 hours as per IEC 61109 |
To be submitted together with the bid. |
| Routine test results | Tenderer shall provide routine test certificate with delivery of insulators |
| Drawings with dimensions | Tenderer shall provide drawings showing the dimensions and tolerances of Insulators offered |
| Applicable Standards for insulation and end fittings |
BS 3288 – 2 1997, IEC 61109 |
| Altitude above sea level | 1400m |
| Operating ambient temperature | -1 to 40 oC |
| Relative humidity (Maximum) | 85% |
| log embossed /printed on the insulator |
Yes |
| S/N |
Detail |
Unit |
Data |
| 1. | Description |
33kV silicon composite pin insulator for mounting on steel cross arms as per drawing ZAM-GEN-87-E-12904 below |
|
| 2. | Type |
Silicon composite pin insulators complete with spindle, washer, nut and lock nut |
|
| 3. | Rated voltage |
kV |
33 |
| 4. | Highest system voltge |
kV |
36 |
| ITE M | Technical Description | Unit | 11kV Silicon Rubber Line Post Insulator with bottom metal fittings complete with spindle for Horizontal Mounting. |
| 1 | Nominal voltage | kV | 11 |
| 2 | Highest system voltage | kV | 12 |
| 3 | Nominal specific Creepage Distance | mm/kV | 25 |
| 4 | Spindle dimensions | mm | As per figure 1.1 attached |
| 5 | Insulator dimensions | mm | As per figure 1.0 attached |
| 6 | Failing load (bend) P0 | kN | 10 |
| 7 | Failing load (Torsion) | Nm | 1.2 |
| 8 | Power frequency wet withstand voltage | kV(r.m .s) – one minute |
28 |
| 9 | Lightning impulse withstand voltage (peak) | kV | 95 |
| 10 | Max Nominal Diameter of Insulating Part | mm | 210 |
| 11 | Material of insulating part | High Temperature Vulcanised Silicon rubber |
|
| 12 | Material of metal parts | Hot dip galvanised steel | |
| 13 | Applicable Standards | BS 137 IEC 61109 ,IEC61952 ,IEC60815-3 |
|
| 14 | Altitude above sea level (m) | 1400 | |
| 15 | Operating ambient temperature (oC) | -1 to 40 | |
| 16 | Relative humidity (%) | 85 | |
| 17 | Type test certificates and results to be provided with bid | Yes/No | Yes |
| 18 | Routine test results/certificates to be provided on delivery | Yes/No | Yes |
| 19 | Drawings showing dimensions of insulators offered to be provided with bid |
Yes/No | Yes |
| 20 | log embossed /printed on the insulator |
Yes/N o |
Yes 173 |
| Item description | 11 kV Silicone composite Pin insulator requirements |
| Type | Silicone composed pin insulator complete with spindle, nut and washer |
| Nominal Voltage (kV) | 11 |
| Highest System Voltage (kV) | 12 |
| Min Nominal Creepage Distance ( mm ) |
280 |
| Min failing load (kN)-Mechanical test |
10 |
| Power frequency withstand voltage (one minute) Wet (kV r.m.s) |
28 |
| Lightning impulse withstand voltage (kV) peak |
95 |
| Material of insulation | High Temperature Vulcanised silicone rubber |
| Spindle diameter (mm) | 20 mm |
| Previous Type Test Certificate/results/report including ageing test at 5000 hours as per IEC 61109 |
To be submitted together with the bid. |
| Routine test results | Tenderer shall provide routine test certificate with delivery of insulators |
| Drawings with dimensions | Tenderer shall provide drawings showing the dimensions and tolerances of Insulators offered |
| Applicable Standards for insulation and end fittings |
BS 3288 – 2 1997, IEC 61109 |
| Altitude above sea level | 1400m |
| Operating ambient temperature | -1 to 40 oC |
| Relative humidity (Maximum) | 85% |
| log embossed /printed on the insulator |
Yes |
We are China 100kv AC and DC High Voltage Withstand Voltage Tester manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Composite Insulator Products
110kv Composite Station Post Insulator
ANSI 51-4f Line Post Insulator/ Polymer Composite Support Insulator
Xgj Suspension Clamp (1, 2, 3)
24kv Composite Silicon Rubber Pin Insulator
110kv Polymer Composite Suspension Insulator
Popular jgtrade1 Products
Terminal Connectors Bolted Type, Type SL, Group a
Pin, Long Shank - 1" Thread X 11-1/2"Length
Fuse Cutout, Drop out Fuses 24kv 300A
Popular Polymer Insulator Products
TR267 composite station post insulator
Tr210 ANSI Solid Core Station Post Insulators for Power Station
36kv Polymer Line Post Insulator for Distribution Line
High Strength Bimetal Clamp Cu-Al 6-50 25-150 mm2
70kv Silicon Pin Insulator 10kn Spr1950XP
Popular Silicone Rubber Insulator Products
Silicone Rubber Insulator for Support Cable
11kv Electrical Glass Disc Suspension Insulator
Surface Inspection on M16X300mm Bolts and Nuts:
Tags: Composite Insulator, jgtrade1, Polymer Insulator, Silicone Rubber Insulator