Copper Conductor Aluminum Armor AC (BX) Cable

China 
                Copper Conductor Aluminum Armor AC (BX) Cable
              manufacture and supplier

Copper Conductor Aluminum Armor AC (BX) Cable image

Get Latest Price Request a quote

Basic Info.

Model NO.
AC(BX) cable

Material Shape
Round Wire

Range of Application
Commercial, Industrial

Certification
ISO9001, CE, UL, CCC, RoHS, VDE

Brand
Huatong

Voltage
Low Voltage 600V, 2000V

Armored Material
Aluminum/Steel Interlock

Transport Package
Coils and Drums

Specification
12AWG to 2000KCMIL

Trademark
Renda

Origin
China

HS Code
8544492100

Production Capacity
200000m/Month

Product Description

 
 
 
APPLICATION
Type MC Cable – Isolated Ground is constructed with soft-drawn copper, Type THHN/THWN
conductors rated 90°C dry available in sizes 12 AWG and 10 AWG, and two insulated grounding conductors–one solid green and the second green with yellow stripes. The conductors are cabled together and a binder tape bearing the print legend is
wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. 

Type AC Cable BX is constructed with soft-drawn copper, Type THHN insulated conductors which are
individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.

 

Power Tray Cable Applications
  • Type MC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
    • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
 
  • Type AC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Dry locations only.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).

STANDARDS & REFERENCES

Type AC Cable meet or exceeds the following requirements
• UL 4, 83, 1581, 2556
• Federal Specification A-A59544 (formerly J-C-30B)
• National Electrical Code Article 320 Armored Cable: Type AC

Type MC Cable meets or exceeds the requirements of the following
• UL 83
• UL 1569
• UL 1685
• Federal Specification A-A59544 (formerly J-C-30B)
• FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
• NEC
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

CONSTRUCTION

Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry
available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.

Type AC Cable is constructed with soft-drawn copper, Type THHN insulated conductors which are
individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.
.

Conductor Size  Solid or Stranded  Grounding Conductor Size  Overall Diameter Weight  Ampacity (Amps)
 (AWG)   (AWG)  (inches)  (lbs./1000ft.)  60 75 90
14-2 Solid  14 0.439 77 15 15 15
14-3 Solid  14 0.464 94 15 15 15
14-4 Solid  14 0.494 112 15 15 15
12-2 Solid  12 0.527 137 20 20 20
12-3 Solid  12 0.505 129 20 20 20
12-4 Solid  12 0.539 155 20 20 20
10-2 Solid  10 0.542 150 30 30 30
10-3 Solid  10 0.58 189 30 30 30
10-4 Solid  10 0.623 229 30 30 30
 

 

We are China Copper Conductor Aluminum Armor AC (BX) Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Electric Cable Products

LV PVC Cable

0.6/1 Kv 2X25mm Aluminium Cable ASTM XLPE Insulation ABC Cable

Low Voltage XLPE Insulated PVC Aluminium Copper Conductor Electric Power Cable

PVC Insulated Electric Power Cable Wire with BS IEC Standard

11kv Overhead Cable ACSR Aluminum Conductor Steel Reinforced for Power Transmission Line

8X6mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1

Popular huatongcables Products

NMB 600V Cable 10/3 UL Standard 12/2 14/2 Thhn Power Cable

Mc-Hl 5kv Armor UL Mc Hl Mchl Ccw Armored Power Mv Cable

Super Flexible Welding Cable 50mm2 Rubber Cable Single Core Rubber Welding Cable

Factory Price PVC cUL Approved 300m Per Roll Nylon 14 T90 Wire

Stranded Photovoltaic System Rpvu Wire 600mcm Solar PV 2kv Rpvu90 Cable Rvp

Low Voltage Flexible Copper Conductor 1/0 AWG Welding Cable

Popular Mc AC Bx Cable Products

600V 1000V #8 to 750 Kcmil Type Teck 90 Aluminum Armored Cable

UL 1569 Thhn Inner Mc/AC/Bx Cable

Aia Interlocked Cable Teck90

Mc Armored Cable Mc/Bx/AC90/Acwu90/Teck90 Cable

600V Armored Cable AC90 Cable

Armor Power Cable Electric Wire Cable Teck90

Popular Type Mc Products

600V 12/2 14/2 Acwu90 Cable

cUL Power Cable Acwu90 Cable

Mc Cable 10/2 10/3 10/4 Mc Metal Clad Cable

Interlocked Aluminum Armored Teck90 Cables

cUL Listed 1000V Teck90

Canadian Building Wire Aluminum Interlocking Armored Cable AC90/Bx

Tags: , , ,