Outdoor High Voltage on Load Break Switch
Outdoor High Voltage on Load Break Switch image
Get Latest Price Request a quote
Basic Info.
Product Description
FW1-12/24/36
Service environment
a)Air temperature: Maximum temperature: +75ºC ; Minimum temperature:-45ºC
b)Humidity: Monthly average humidity 95%; Daily average humidity 90% .
c)Altitude above sea level: Maximum installation altitude: 2500m
d)Ambient air not apparently polluted by corrosive and flflammable gas, vapor etc.
e)No frequent violent shake
Features and benefifits
•Compact design
•All steel parts either in stainless steel or hot-dip galvanized
•Solid and stable base frame
•Main contact with icing protection
•Insulators available in porcelain or alternatively in silicone
•Minimal sag for the line-connection thanks to the two fifixed terminals
•Completely maintenance antirust AL alloy -Arc chamber
•Switching-off procedure without external arc
•Short circuit making capacity under specifific conditions possible
•Fixing on the supporting structure either by clamping (free setting) or screwing (holes in the base frame)
•Easy on-site installation and setting
•High reliability: up to 1’000 cycles (depending on the making current)
•All conducting parts either silver, nickel or tin-plated
•Practically maintenance-free
| No | Item | Unit | Date | |||
| 1 | Rated voltage | Kv | 12 | 24 | 36 | |
| 2 | Rated frequency | Hz | 50/60 | |||
| 3 | Rated current | A | 200/400/630 | |||
| 4 | Rated short circuit withstand current |
KA |
20 | |||
| 5 | Rated peak withstand current | KA | 50 | |||
| 6 | Rated making current | KA | 31.5-50 | |||
| 7 |
Rated insulation level(HV) |
lighting impulse |
KV |
75/85 | 125/145 | 170/195 |
| Power frequency withstand | 45 | 55/75 | 75/100 | |||
| 8 |
for active circuits |
20 breakings | A | 630 | 630 | 400 |
| 30 breakings | 400 | 400 | 300 | |||
| 40 breakings | 300 | 300 | 250 | |||
| 50 breakings | 250 | 250 | 170 | |||
| 75 breakings | 170 | 170 | 160 | |||
| 120 breakings | 110 | 110 | 110 | |||
| 200 breakings | 65 | 65 | 65 | |||
| 280 breakings | 50 | 50 | 50 | |||
| 9 | For ring circuits breaking capacity | 630 | 400 | 250 | ||
| 10 | Rated breaking capacity of transformer | 50 | 50 | 50 | ||
| 11 | Rated breaking capacity of cable charging | 11 | 11 | 11 | ||
| 12 | Rated breaking capacity of earthing fault | 56 | 56 | 56 | ||
We are China Outdoor High Voltage on Load Break Switch manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular High Voltage on Load Break Switch Products
Popular Outdoor High Voltage Load Break Switch Products
12kv Outdoor High Voltage on Load Break Switch
24kv Outdoor High Voltage on Load Break Switch
36kv Outdoor High Voltage on Load Break Switch
Popular Outdoor on Load Break Switch Products
Popular people Products
66kv /120kn Polymeric Suspension Long Rod Insulator
Power Fitting Al Alloy -Arc Chamber
24kv 5kn Polymer Line Horizontal Post Insulator
12kv High Quality Overhead Transmission Line Composite Post Insulator
54kv Polymeric Housed Metal Oxide Surge Arrester
15kv 100A/200A Polymer Expulsion Fuse Cutout
Tags: High Voltage on Load Break Switch, Outdoor High Voltage Load Break Switch, Outdoor on Load Break Switch, people