En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables
En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables image
Get Latest Price Request a quote
Basic Info.
Product Description
APPLICATION
En50228-7 LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas.
The galvanized steel wire armour provides excellent protection. Generally, the cables are used within industrial
process manufacturing plants for communication, data and voice transmission signals and services. Also used for
the interconnection of electrical equipmentand instruments, the LSZH sheath can reduce toxic smoke and fume
emission.
STANDARDS
Basic design to EN 50288-7
FIRE PERFORMANCE
| Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
| Reduced Fire Propagation(Vertically-mounted bundled wires & cable test)*** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
| Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;CEI 20-37/2-1 ; BS 6425-1* |
| No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;CEI 20-37/2-2 ; BS 6425-2* |
| Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
| No Toxic gases | NES 02-713; NF C 20-454 |
| Sunlight Resistance | UL 1581 section 1200 |
| Oil Resistance** | ICEA S-73-532 |
Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.
VOLTAGE RATING
500V
Construction:
1. Conductor Cu conductor of the category 1 according to IEC 60228
2. Insulation XLPE
3. Cable core cores are twisted in pairs, pairs are laid up into cable core
4. Bedding none
5. Screening wrapping by Al/PET foil + CuSn drain wire
6. Sheath fire retardant halogen-free polymer compound
Mechanical and Electrical Properties
Rated voltage: 500 V AC
Testing voltage between cores: 2000 V
Testing voltage between core and screening: 750 V
Insulation resistance: > 1000 MΩ.km
Surrounding temperatures (fixed placement): – 40°C up to + 90°C
Surrounding temperatures (during installation): -5°C up to +50°C
Minimum bending radius (fixed placement): 10D
Cable Design Parameters
| RE-2X(St)H PiMF | ||||
| No. of Pairs x2xCross Section | Nominal Insulation Thickness | Nominal Outer Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
| No.x2xmm2 | mm | mm | mm | kg/km |
| 0.5mm2, Multipair | ||||
| 2x2x0.5 | 0.35 | 0.9 | 8.7 | 85 |
| 4x2x0.5 | 0.35 | 1.0 | 10.2 | 120 |
| 5x2x0.5 | 0.35 | 1.0 | 11.2 | 145 |
| 6x2x0.5 | 0.35 | 1.0 | 12.1 | 170 |
| 8x2x0.5 | 0.35 | 1.1 | 13.1 | 214 |
| 10x2x0.5 | 0.35 | 1.2 | 15.1 | 265 |
| 12x2x0.5 | 0.35 | 1.2 | 15.7 | 286 |
| 16x2x0.5 | 0.35 | 1.2 | 17.8 | 380 |
| 20x2x0.5 | 0.35 | 1.3 | 19.7 | 475 |
| 24x2x0.5 | 0.35 | 1.4 | 21.5 | 561 |
| 0.75mm2, Multipair | ||||
| 2x2x0.75 | 0.38 | 1.0 | 9.7 | 101 |
| 3x2x0.75 | 0.38 | 1.0 | 11.2 | 159 |
| 4x2x0.75 | 0.38 | 1.1 | 12.5 | 183 |
| 5x2x0.75 | 0.38 | 1.1 | 13.6 | 215 |
| 8x2x0.75 | 0.38 | 1.1 | 14.4 | 272 |
| 10x2x0.75 | 0.38 | 1.2 | 16.6 | 333 |
| 12x2x0.75 | 0.38 | 1.2 | 17.4 | 383 |
| 16x2x0.75 | 0.38 | 1.3 | 19.8 | 492 |
| 20x2x0.75 | 0.38 | 1.4 | 22.0 | 603 |
| 24x2x0.75 | 0.38 | 1.5 | 24.0 | 704 |
| 1.0mm2, Multipair | ||||
| 2x2x1.0 | 0.4 | 1.0 | 10.4 | 112 |
| 3x2x1.0 | 0.4 | 1.0 | 12.1 | 179 |
| 4x2x1.0 | 0.4 | 1.1 | 13.5 | 220 |
| 5x2x1.0 | 0.4 | 1.1 | 14.7 | 256 |
| 8x2x1.0 | 0.4 | 1.2 | 15.8 | 323 |
| 10x2x1.0 | 0.4 | 1.2 | 18.0 | 401 |
| 12x2x1.0 | 0.4 | 1.3 | 19.0 | 454 |
| 16x2x1.0 | 0.4 | 1.3 | 21.5 | 601 |
| 20x2x1.0 | 0.4 | 1.4 | 23.9 | 719 |
| 24x2x1.0 | 0.4 | 1.5 | 26.1 | 884 |
| 1.3mm2, Multipair | ||||
| 2x2x1.3 | 0.45 | 1.0 | 11.4 | 153 |
| 3x2x1.3 | 0.45 | 1.1 | 13.4 | 208 |
| 4x2x1.3 | 0.45 | 1.1 | 14.8 | 263 |
| 5x2x1.3 | 0.45 | 1.2 | 16.3 | 318 |
| 8x2x1.3 | 0.45 | 1.3 | 17.6 | 406 |
| 10x2x1.3 | 0.45 | 1.3 | 20.0 | 501 |
| 12x2x1.3 | 0.45 | 1.4 | 21.1 | 552 |
| 16x2x1.3 | 0.45 | 1.5 | 24.1 | 728 |
| 20x2x1.3 | 0.45 | 1.6 | 26.8 | 892 |
| 24x2x1.3 | 0.45 | 1.7 | 29.2 | 1067 |
| 1.5mm2, Multipair | ||||
| 2x2x1.5 | 0.45 | 1.0 | 11.8 | 164 |
| 3x2x1.5 | 0.45 | 1.1 | 13.9 | 235 |
| 4x2x1.5 | 0.45 | 1.2 | 15.5 | 289 |
| 5x2x1.5 | 0.45 | 1.2 | 16.9 | 366 |
| 8x2x1.5 | 0.45 | 1.3 | 18.2 | 446 |
| 10x2x1.5 | 0.45 | 1.4 | 21.0 | 565 |
| 12x2x1.5 | 0.45 | 1.4 | 21.9 | 637 |
| 16x2x1.5 | 0.45 | 1.5 | 25.1 | 828 |
| 20x2x1.5 | 0.45 | 1.6 | 27.8 | 1024 |
| 24x2x1.5 | 0.45 | 1.7 | 30.4 | 1219 |
Note : Other conductor sizes & core configurations are available upon request
Packing shipping
We are China En50228-7 LSZH Twisted Pair Individual & Overall Screened Instrumentation Cables manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular En50228-7 Products
Popular En50228-7 Instrumentation Cables Products
Popular En50228-7 LSZH Products
Popular zzhongdacable Products
Low Voltage Cu XLPE PVC Insulated 3X2.5mm 3 Core 2.5mm2 U1000 RO2V Copper Wire Cable
AAC/AAAC/ACSR Greased Conductors for Overhead Transmission
Copper 3 Core 150mm2 240mm XLPE Power Cable
Low Voltage 0.6/1kv Aluminum XLPE Insulated Na2xy Power Cable
PVC Insulation 7 Wire Stranded Copper Conductor Wire Cable Thw 4 AWG 600V
Medium Voltage 11kv 240mm2 Copper XLPE Insulated Steel Wire Armored Power Cable
Tags: En50228-7, En50228-7 Instrumentation Cables, En50228-7 LSZH, zzhongdacable