Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR
Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR image
Get Latest Price Request a quote
Quick Details
Product Details
Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR
1.Applications
Conductor(AAC,AAAC and ACSR) have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.
2.Service Performance
(1).The permissible long-time operating temperature for aerial conductor is 70oC.
(2).Under the circumstance that rare climate is occuring and ice coverage rate low in heavy ice area,the biggest stress of cable at the lowest point of the sag should not exceed 60% of the short-time destructive power.
(3).When connecting conductors,the conductor beside the connecting tube cant be prominent.Otherwise,the force on the operating conductors will be unbalanced.After connectors are install,the connecting tube should be painted by moisture-proof varnish in order to protect it from corrosion.
(4).Under installaion,the arc downing stress of all the conductors should be the same.With in the permissible distance of crossing buildings or dropping to the ground,the stress can be 10-15% higher than regular stress.
3.Material Standard
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T 17048-1997(equivalent to IEC 60889:1987).
(2).The zinc coated steel wire used for ACSR conforms to IEC 60888:1987.
(3).Production can be arranged according to customers requirements for material standard,etc.
Construction of All Aluminum Conductor and Aluminum Conductor Steel Reinforced
4.Technical details
AAC Technical Characteristics Based on Standard DIN 48201 / DIN EN50182
| Code number | Area | Number of wires | Wire diameter | Conductor diameter | Linear mass | Rated strength | D.C. resistance at 20oC |
| mm2 | No. | mm | mm | kg/km | kN | Ω/km | |
| 16 | 15.9 | 7 | 1.7 | 5.1 | 43.4 | 3.02 | 1.7986 |
| 25 | 24.2 | 7 | 2.1 | 6.3 | 66.3 | 4.36 | 1.1787 |
| 35 | 34.4 | 7 | 2.5 | 7.5 | 93.9 | 6.01 | 0.8317 |
| 50 | 49.5 | 7 | 3 | 9 | 135.2 | 8.41 | 0.5776 |
| 50 | 48.3 | 19 | 1.8 | 9 | 132.9 | 8.94 | 0.5944 |
| 70 | 65.8 | 19 | 2.1 | 10.5 | 180.9 | 11.85 | 0.4367 |
| 95 | 93.3 | 19 | 2.5 | 12.5 | 256.3 | 16.32 | 0.3081 |
| 120 | 117 | 19 | 2.8 | 14 | 321.5 | 19.89 | 0.2456 |
| 150 | 147.1 | 37 | 2.25 | 15.8 | 405.7 | 26.48 | 0.196 |
| 185 | 181.6 | 37 | 2.5 | 17.5 | 500.9 | 31.78 | 0.1588 |
| 240 | 242.5 | 61 | 2.25 | 20.3 | 671.1 | 43.66 | 0.1193 |
| 300 | 299.4 | 61 | 2.5 | 22.5 | 828.5 | 52.4 | 0.0966 |
ACSR Technical Characteristics Based on Standard BS 215-2
| Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area of aluminium | Total sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load | |
| Al | Steel | ||||||||
| mm2 | No./mm | mm2 | mm2 | mm | kg/km | Ω/km | kN | ||
| RABBIT | 50 | 6/3.35 | 1/3.35 | 52.88 | 61.7 | 10.05 | 214 | 0.5426 | 18.35 |
| DOG | 100 | 6/4.72 | 7/1.57 | 105 | 118.5 | 14.15 | 394 | 0.2733 | 32.7 |
| WOLF | 150 | 30/2.59 | 7/2.59 | 158.1 | 194.9 | 18.13 | 726 | 0.1828 | 69.2 |
| DINGO | 150 | 18/3.35 | 1/3.35 | 158.7 | 167.5 | 16.75 | 506 | 0.1815 | 35.7 |
| LYNX | 175 | 30/2.79 | 7/2.79 | 183.4 | 226.2 | 19.53 | 842 | 0.1576 | 79.8 |
| ZEBRA | 400 | 54/3.18 | 7/3.18 | 428.9 | 484.5 | 28.62 | 1621 | 0.0674 | 131.9 |
AAAC Technical Characteristics Based on Standard BS 3242
| Code name | Nominal aluminium area | Stranding and wire diameter | Sectional area | Approx. overall diameter | Approx. mass | Calculated D.C. resistance at 20oC | Calculated breaking load |
| mm2 | No./mm | mm2 | mm | kg/km | Ω/km | kN | |
| ALMOND | 25 | 7/2.34 | 30.1 | 7.02 | 82 | 1.094 | 8.44 |
| CEDAR | 30 | 7/2.54 | 35.47 | 7.62 | 97 | 0.9281 | 9.94 |
| FIR | 40 | 7/2.95 | 47.84 | 8.85 | 131 | 0.688 | 13.4 |
| HAZEL | 50 | 7/3.30 | 59.87 | 9.9 | 164 | 0.5498 | 16.8 |
| OAK | 100 | 7/4.65 | 118.9 | 13.95 | 325 | 0.2769 | 33.3 |
| ASH | 150 | 19/3.48 | 180.7 | 17.4 | 497 | 0.183 | 50.65 |
| ELM | 175 | 19/3.76 | 211 | 18.8 | 580 | 0.1568 | 59.1 |
| UPAS | 300 | 37/3.53 | 362.1 | 24.71 | 997 | 0.09155 | 101.5 |
Company Information
We are China Bare Aluminum Conductor Overhead Cable AAC AAAC ACSR manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Conductor Products
Coreopsis 1590mcm AAC All Aluminum Conductor
Factory Price AAC AAAC ACSR Aluminum Alloy Conductor ASTM IEC Standard
Made in China Factory Supply AAC AAAC ACSR Conductor 336.4 477mcm Twisted Stranded Bare Conductor
IEC ASTM BS Standard Bare AAC Conductor for Overhead
AAC All Aluminum Stranded Conductor, Overhead Bare Cable.
Popular Aluminum Conductor Products
Aluminum Conductor XLPE Insulated Low Voltage Overhead 0.6/1kv Power Cable
AAAC Wire Aluminum Conductor Overhead Cable
AAC AAAC ACSR Acar Acss Acss/Aw Bare Overhead Conductor
ACSR Conductor Aluminum Conductors Steel Reinforced for Hot Sale
Type of AAC All Aluminum Conductor Stranded
Popular Aluminum Wire Products
Copper or Aluminum Conductor PVC Insulation Electrical Wire
Tie Wire, Solid Aluminum 1350 Wire (ASTM B 609)
AAC Conductor Aluminum Stranded Conductor
PVC Coated Electric Aluminum Wire Flexible Cable
Hot Sale Electrical 6201 Aluminum Wire Rod Metal Aluminum Alloy Wire
150mm2 All Aluminum Conductor, Bare
Popular zzjinshui Products
15kv Aluminum Conductor XLPE Insulation 3 Core Power Cable 50mm2
1kv 4 Core XLPE Insulated Steel Wire Armoured Cable 70mm2
Bare Aluminum AAC Carnation Conductor
Aluminum Conductive Core IEC Standard Power Cable Sizes
Ground Cable with Aluminum Core
Low Voltage 4 Core Copper Conductor Steel Tape Armored Cable
Tags: AAC Conductor, Aluminum Conductor, Aluminum Wire, zzjinshui