Factory Direct Sales 6/10 Kv 12/20 Kv 18/30 Kv Medium Voltage Cable Single Core Cables to IEC 60502

China 
                Factory Direct Sales 6/10 Kv 12/20 Kv 18/30 Kv Medium Voltage Cable Single Core Cables to IEC 60502
              manufacture and supplier

Factory Direct Sales 6/10 Kv 12/20 Kv 18/30 Kv Medium Voltage Cable Single Core Cables to IEC 60502 image

Get Latest Price Request a quote

Basic Info.

Model NO.
MV cable

Wire Core Material
Bare Copper Wire

Certification
ISO, CCC

Model
Mv Cable

Brand
Yifang

Standard
IEC60502-2

Transport Package
Steel Wooden Drum

Specification
25mm2 to 400m2

Trademark
yifang

Origin
China

HS Code
8544492100

Production Capacity
10000m Per Week

Product Description

Medium Voltage Cable Single Core Cables to IEC 60502

APPLICATIONS

The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV and frequency 50Hz.

They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

STANDARD

  • IEC 60502 Part 1(1.8/3KV)
  • IEC 60502 Part 2(3.6/6KV to 18/30KV)
Conductor Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2.
Conductor Screen The conductor screen consists of an extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation to exclude all air voids. The conductor screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables.
Insulation Insulation is of polyvinyl chloride (PVC) intended for 1.8/3KV and 3.6/6KV cables, cross-linked polyethylene compound (XLPE) or ethylene propylene rubber (EPR/HEPR).

Table 1. Insulation Thickness of XLPE or EPR/HEPR Insulation

Nom. Cross Section Area Insulation Thickness at Nominal Voltage
1.8/3KV (Um=3.6KV) 3.6/6KV (Um=7.2KV) 6/10KV (Um=12KV) 8.7/15KV (Um=17.5KV) 12/20KV (Um=24KV) 18/30KV (Um=36KV) 21/35KV (Um=42KV) 26/35KV (Um=42KV)
mm^2 mm mm mm mm mm mm mm mm
  XLPE/EPR XLPE EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR XLPE/EPR
Unscreened Screened
10 2.0 2.5 3.0 2.5
16 2.0 2.5 3.0 2.5 3.4
25 2.0 2.5 3.0 2.5 3.4 4.5
35 2.0 2.5 3.0 2.5 3.4 4.5 5.5
50 – 185 2.0 2.5 3.0 2.5 3.4 4.5 5.5 8.0 9.3 10.5
240 2.0 2.6 3.0 2.6 3.4 4.5 5.5 8.0 9.3 10.5
300 2.0 2.8 3.0 2.8 3.4 4.5 5.5 8.0 9.3 10.5
400 2.0 3.0 3.0 3.0 3.4 4.5 5.5 8.0 9.3 10.5
500 – 1600 2.2-2.8 3.2 3.2 3.2 3.4 4.5 5.5 8.0 9.3 10.5

*Insulation Thickness of PVC is 3.4mm (1- 1600mm sq) for 3.6/6KV cables.

Insulaton Screen The insulation screen consists of an extruded layer of non metallic, semiconducting compound extruded over the insulation. The extruded semi-conducting layer shall consist of bonded or cold strippable semi-conducting compound capable of removal for jointing or terminating. As an option, a semi-conducting tape may be applied over the extruded semi-conducting layer as a bedding for the metallic layer. The minimum thickness is 0.3 mm and the maximum resistivity is 500 Ohm-m at 90°C. The screen is tightly fitted to the insulation to exclude all air voids and can be easily hand stripped on site. The insulation screen is not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables. The screen may be covered by semi-conductive water blocking swellable tape to ensure longitudinal watertightness.
Metallic Layer The metallic layer may be applied over the individual cores or the core assembly collectively.

 

The following types of metallic layers are provided:

1) Metallic Screen
2) Concentric Conductor
3) Metallic Sheath
4) Metallic armour

The metallic screen shall consist of either copper tapes or a concentric layer of copper wires or a combination of tapes and wires to provide an earth fault current path. The concentric conductor is applied directly either over the insulation, or over the insulation screen or over an inner covering. The metallic sheath consists of lead or lead alloy applied as a tightly fitting seamless tube. The metallic armour consists of either flat wire armour, round wire armour, and double tape armour.

Table 2. Minimum Total Cross Section of Metallic Screen

Nom. Cross-Section Area of Cable Min. Cross-Section of Metallic Screen DC Resistance of the Copper Wire Screen
mm^2 mm^2 mm
up to 120 16 1.06
150-300 25 0.72
400-630 35 0.51
800-1000 50 0.35

 

Separation Sheath (for armoured cable) The separation sheath comprises a layer of extruded PVC, PE or LSZH, applied under the armour. The nominal thickness is calculated by 0.02Du + 0.6mm where Du is the fictitious diameter under the sheath in mm. For cables without a lead sheath, the nominal separation sheath thickness shall not be less than 1.2mm. For cables where the separation sheath is applied over the lead sheath, the nominal separation sheath thickness shall not be less than 1.0mm.
Lapped Bedding (for armoured lead sheathed cable) The lapped bedding consists of either impregnated/synthetic compounded paper tapes or a combination of two layers of these paper tapes followed by a few layers of compounded fabulous materials. The thickness is around 1.5mm.
Armour (for armoured cable) The armour consists of round aluminium wire armour applied helically over an extruded separation sheath.

Table 3. Round Armour Wire Diameter

Fictitious Diameter under the Armour Armour Wire Diameter
mm mm
> <  
10 0.8
10 15 1.25
15 25 1.6
25 35 2.0
35 60 2.5
60 3.15

 

Over Sheath Overall sheath comprises a layer of extruded thermoplastic compound (PVC, PE or LSZH can be offered as an option.) or elastomeric compound (polychlorprene CSP or chlorosulfonated PE). The nominal over sheath thickness is calculated by 0.035D+1 where D is the fictitiuous diameter immediately under the over sheath in mm. For unarmoured cables and cables with the over sheath not applied over the armour, metallic screen or concentric conductor, the nominal over sheath thickness shall not be less than 1.4mm. And for cables with over sheath applied over the armour, metallic screen or concentric conductor, the nominal over sheath thickness shall not be less than 1.8mm.

PHYSICAL PROPERTIES

Operating Temperature up to 70°C (PVC insulation); up to 90°C (XLPE or EPR insulation)
Temperature Range -5°C ( PVC or LSZH sheath ); -20°C ( PE sheath )
Short Circuit Temperature( 5 seconds maximum duration ) 140-160°C (PVC insulation) ; 250°C (XLPE or EPR insulation)
Bending Radius 12 x OD

Table 4. Nominal /Operating /Testing Voltages

Rated Voltage Uo/U Operating Voltage (Um) Testing Voltage (rms)
1.8/3KV 3.6KV 6.5KV
3.6/6KV 7.2KV 12.5KV
6/10KV 12KV 21KV
8.7/15KV 17.5KV 30.5KV
12/20KV 24KV 42KV
18/30KV 36KV 63KV
21/35KV 42KV 73.5(53)*KV
26/35KV 42KV 91(65)*KV

*21/35KV and 26/35KV power frequency voltage test can be made under the following conditions: 2.5Uo x 30mins or 3.0Uo x 15mins.

Numbers in brackets refer to the test values for 3.0Uo x 1.5mins.

Single Core 1.8/3KV (Um=3.6KV)

Our company

Yifang Electric group mainly specialized in wire&cables,including designment,production and sale.

Products are mainly covering low,medium,high voltage(1KV to 220KV) XLPE Insulated power cable,PVC insulated power cable,ABC cable,building cable control cable,rubber cable welding cable Etc.

Our XLPE cable can be manufactured according to the company’s specification which is equivalent to IEC 60502,IEC60332,IEC60754. Some indexes are superior to above international standard.

Our certificate


FAQ
1.Q:Are you a factory or trading company? 
 A: Manufacturing base in Henan ,China, with more than 500 workers.

2.Q:How can I visit there? 
 A: Sure,If you need,we will arrange the driver to pick you up. 

3.Q:How can I get some samples? 
 A: Contact me on below,Determin sample and address for shipping.  

4.Q:Have you ever supplied cables to our country? 
 A: Yifang Cables have been sold to over 100 countries and regions in the world. can you contact me for details.

5.Q:What is your MOQ? 
A: MOQ Normally 500 meters for big diameter cables.Please contact me for detail info if you have specific cable requirement. 

6. Q:When can I get the price? 
A: Usually quote within 6 hours after we get your inquiry. 

7.Q:How long is your delivery time?
 A: According to your order’s quantity.Usually our lead time is 3 – 20 working days.
 

We are China Factory Direct Sales 6/10 Kv 12/20 Kv 18/30 Kv Medium Voltage Cable Single Core Cables to IEC 60502 manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular Factory Direct Sales 6/10 Kv 12/20 Kv 18/30 Kv Medium Voltage Cable Single Core Cables to IEC 60502 Products

  • No related articles
  • Popular Medium Voltage Cable Products

    Mv 105 Cable Trxlpe 100% Insulation Concentric Neutral Power Urd Cable

    35kv Single Core 1000mcm Aluminum Tr-XLPE Cws LLDPE Mv90 Cable

    1/0 2/0 AWG XLPE 15kv 25kv 35kv Medium Voltage Urd Mv105 Cable Mv90

    High Tension 20kv 35kv 3 Core Aluminum XLPE Armoured Cable

    12/20kv Submarine Cable 3X185mm2

    3 Core Copper Conductor Medium Voltage Armoured XLPE Insulated Power Cable

    Popular Single Core Cable Products

    600V Single Conductor Urd Power Cable

    4mm Single Core Cable 500mm Cable

    Single Core Electrical Copper Wire Cable 1.5mm 2.5mm 4mm 6mm Electric Wire

    Split Concentric Cable 16mm2 10mm2 Aluminium Conductor

    16mm Split Concentric Cable Price Aluminium XLPE Insulation LLDPE Sheath

    LV Single Core Aluminum Conductor PE/XLPE Insulation Overhead Cable

    Popular yifangcable Products

    0.6/1kv Power Cable Cu/XLPE/Swa/PVC

    Aluminum Conductor Shepherd XLPE Insulation Twisted Overhead Cable Duplex ABC Cable

    Copper Tape Screen Wrapped Middle Voltage PVC/PE Sheathed XLPE Insulated Cable Copper Cable

    ABC XLPE Cable 0.6/1kv 3X70+54.6+2X16

    Type SHD-GC Three-Conductor Portable Power Cable, CPE Sheath 8kV Cable

    Triplex (2+1) Service Drop Aluminum Conductor Cable

    Tags: , , ,

    FAST AND RELIABLE SERVICE FOR YOUR PROJECT

    Contact our trained experts today to find your perfect power solution.

    ASK A QUESTION