Direct Manufacture PVC Insulated and Sheathed Power Cable
Direct Manufacture PVC Insulated and Sheathed Power Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
- Company Profile
Basic Info.
Packaging & Delivery
Product Description
Application:
With the characteristics of stable capability,advanced technology,broad material resources,low price, good flexible and easy to lay and maintain, the PVC Insulated and Sheathed Power Cable are suitable to be laid for distribution line with A.C.50HZ and rated voltage up to 6kV.
Property:
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Specification:
Standard:
IEC,BS,VDE,AS/NZS,ICEA,JIS and so on,designing and manufacturing special power cable according to the other standards required by the customer
1)600/1000V, Single Core, Circular Compacted Al or Cu/PVC/PVC Unarmoured or Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Unarmoured |
Armoured |
||||||||
|
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
Thickness of Bedding |
Thickness of Al Tape |
Thickness of Sheath |
Overall Dia. |
jpcable99.en. Weight |
|||||
|
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||||||
|
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
|
1.5 |
1 |
0.8 |
1.4 |
5.8 |
– |
51 |
– |
– |
– |
– |
– |
– |
|
2.5 |
1 |
0.8 |
1.4 |
6.2 |
– |
64 |
– |
– |
– |
– |
– |
– |
|
4 |
1 |
1 |
1.4 |
7.1 |
– |
88 |
– |
– |
– |
– |
– |
– |
|
6 |
7 |
1 |
1.4 |
7.8 |
78 |
114 |
– |
– |
– |
– |
– |
– |
|
10 |
7 |
1 |
1.4 |
8.6 |
96 |
159 |
1 |
0.5 |
1.8 |
13.4 |
234 |
295 |
|
16 |
7 |
1 |
1.4 |
9.6 |
123 |
222 |
1 |
0.5 |
1.8 |
14.4 |
274 |
370 |
|
25 |
7 |
1.2 |
1.4 |
11.2 |
172 |
328 |
1 |
0.5 |
1.8 |
16 |
344 |
496 |
|
35 |
7 |
1.2 |
1.4 |
12.2 |
209 |
428 |
1 |
0.5 |
1.8 |
17 |
393 |
606 |
|
50 |
19 |
1.4 |
1.4 |
13.9 |
271 |
565 |
1 |
0.5 |
1.8 |
18.7 |
478 |
764 |
|
70 |
19 |
1.4 |
1.5 |
15.9 |
356 |
818 |
1 |
0.5 |
1.8 |
20.5 |
582 |
1020 |
|
95 |
19 |
1.6 |
1.5 |
18 |
471 |
1041 |
1 |
0.5 |
1.8 |
22.6 |
717 |
1291 |
|
120 |
37 |
1.6 |
1.6 |
19.6 |
563 |
1307 |
1 |
0.5 |
1.8 |
24 |
822 |
1545 |
|
150 |
37 |
1.8 |
1.6 |
21.3 |
684 |
1592 |
1 |
0.5 |
1.8 |
25.4 |
952 |
1857 |
|
185 |
37 |
2 |
1.7 |
23.9 |
840 |
1985 |
1 |
0.5 |
1.8 |
27.9 |
1136 |
2236 |
|
240 |
61 |
2.2 |
1.8 |
27 |
1071 |
2533 |
1 |
0.5 |
1.9 |
31 |
1404 |
2877 |
|
300 |
61 |
2.4 |
1.9 |
29.6 |
1317 |
3162 |
1.2 |
0.5 |
2.1 |
34.3 |
1722 |
3551 |
|
400 |
61 |
2.6 |
2 |
33.2 |
1666 |
4120 |
1.2 |
0.5 |
2.2 |
37.6 |
2114 |
4488 |
|
500 |
61 |
2.8 |
2.2 |
37.5 |
2089 |
5163 |
1.2 |
0.5 |
2.3 |
42.1 |
2592 |
5683 |
|
630 |
61 |
2.8 |
2.3 |
41.2 |
2581 |
6447 |
1.4 |
0.5 |
2.4 |
46.3 |
3184 |
7060 |
2)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|
|
Al Conductor |
Cu Conductor |
||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
Three Cores |
3×35 |
16 |
1.2 |
1.8 |
21.9 |
601 |
1280 |
|
3×50 |
18 |
1.4 |
1.8 |
26.5 |
829 |
1732 |
|
|
3×70 |
18 |
1.4 |
1.9 |
29.2 |
1067 |
2367 |
|
|
3×95 |
36 |
1.6 |
2 |
32.9 |
1409 |
2317 |
|
|
3×120 |
36 |
1.6 |
2.1 |
36.2 |
1705 |
3983 |
|
|
3×150 |
36 |
1.8 |
2.2 |
38.8 |
2045 |
4872 |
|
|
3×185 |
36 |
2 |
2.4 |
44.8 |
2596 |
6077 |
|
|
3×240 |
60 |
2.2 |
2.6 |
51.5 |
3353 |
7953 |
|
|
3×300 |
60 |
2.4 |
2.7 |
54.9 |
6069 |
9820 |
|
|
Four Cores with Reduced Neutral |
3×35+16 |
16-7 |
1.2-1 |
1.8 |
25.5 |
764 |
1107 |
|
3×50+25 |
18-16 |
1.4-1.2 |
1.9 |
28.7 |
982 |
1410 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
2.0 |
32 |
1278 |
1733 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
2.2 |
37.8 |
1711 |
2656 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
2.3 |
40.5 |
2065 |
3137 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
2.4 |
44.8 |
2480 |
3660 |
|
|
3×185+95 |
36-36 |
2-1.6 |
2.6 |
49.7 |
3086 |
4345 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
2.8 |
56 |
3894 |
5441 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
2.9 |
60.3 |
4834 |
6494 |
|
|
Four Cores |
4×25 |
16 |
1.2 |
1.8 |
22.5 |
644 |
1286 |
|
4×35 |
16 |
1.2 |
1.8 |
24.6 |
799 |
1696 |
|
|
4×50 |
18 |
1.4 |
1.8 |
28.6 |
1071 |
2275 |
|
|
4×70 |
18 |
1.4 |
2 |
31.6 |
1387 |
3120 |
|
|
4×95 |
36 |
1.6 |
2.1 |
35.9 |
1850 |
4262 |
|
|
4×120 |
36 |
1.6 |
2.2 |
38.8 |
2209 |
5247 |
|
|
4×150 |
36 |
1.8 |
2.3 |
43.1 |
2714 |
6483 |
|
|
4×185 |
36 |
2 |
2.5 |
48.7 |
3403 |
8045 |
|
|
4×240 |
60 |
2.2 |
2.7 |
53.6 |
4290 |
10422 |
|
|
4×300 |
60 |
2.4 |
2.9 |
58.8 |
5302 |
12969 |
|
3)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Unarmoured Power Cable
|
Number of Cores |
Cross-Section of Conductor |
No. Of Wires |
Thickness of Insulation |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||
|
Al Conductor |
Cu Conductor |
|||||||
|
– |
mm2 |
– |
mm |
mm |
mm |
kg/km |
kg/km |
|
|
Three Cores |
3×10 |
7 |
1 |
1.8 |
16.6 |
281 |
465 |
|
|
3×16 |
7 |
1 |
1.8 |
18.7 |
387 |
679 |
||
|
3×25 |
7 |
1.2 |
1.8 |
22.2 |
536 |
996 |
||
|
3×35 |
7 |
1.2 |
1.8 |
24.4 |
665 |
1311 |
||
|
3×50 |
19 |
1.4 |
1.9 |
28.1 |
863 |
1729 |
||
|
3×70 |
19 |
1.4 |
2 |
32.3 |
1153 |
2480 |
||
|
3×95 |
19 |
1.6 |
2.1 |
37.1 |
1563 |
3301 |
||
|
3×120 |
37 |
1.6 |
2.3 |
40.4 |
1850 |
4040 |
||
|
3×150 |
37 |
1.8 |
2.4 |
43.9 |
2258 |
5000 |
||
|
3×185 |
37 |
2 |
2.5 |
49.2 |
2819 |
6151 |
||
|
3×240 |
61 |
2.2 |
2.8 |
55.9 |
3577 |
8040 |
||
|
3×300 |
61 |
2.4 |
3 |
62.1 |
4413 |
9955 |
||
|
3×400 |
61 |
2.6 |
3.2 |
69.3 |
5512 |
12705 |
||
|
Four Cores |
4×10 |
7 |
1 |
1.8 |
18.1 |
343 |
589 |
|
|
4×16 |
7 |
1 |
1.8 |
20.5 |
487 |
874 |
||
|
4×25 |
7 |
1.2 |
1.8 |
24.3 |
677 |
1291 |
||
|
4×35 |
7 |
1.2 |
1.8 |
26.8 |
821 |
1681 |
||
|
4×50 |
19 |
1.4 |
2 |
31.2 |
1118 |
2273 |
||
|
4×70 |
19 |
1.4 |
2.1 |
35.8 |
1494 |
3264 |
||
|
4×95 |
19 |
1.6 |
2.3 |
41.2 |
1993 |
4312 |
||
|
4×120 |
37 |
1.6 |
2.4 |
44.8 |
2370 |
5291 |
||
|
4×150 |
37 |
1.8 |
2.5 |
48.7 |
2959 |
6615 |
||
|
4×185 |
37 |
2 |
2.7 |
54.7 |
3601 |
8044 |
||
|
4×240 |
61 |
2.2 |
3 |
62.1 |
4596 |
10547 |
||
|
4×300 |
61 |
2.4 |
3.2 |
69.1 |
5614 |
13004 |
||
4)600/1000V, Multi Cores, Sectoral Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
||||||
|
STA |
SWA |
|||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
|||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
|
Three Cores |
||||||||||||||
|
3×35 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
24.7 |
28.2 |
912 |
1591 |
1447 |
2126 |
|
|
3×50 |
18 |
1.4 |
1 |
0.2 |
46/1.6 |
1.9 |
2 |
29.3 |
32.8 |
1202 |
2105 |
1842 |
2745 |
|
|
3×70 |
18 |
1.4 |
1.2 |
0.2 |
41/2.0 |
2.0 |
2.2 |
32.5 |
37.1 |
1520 |
2820 |
2475 |
3775 |
|
|
3×95 |
36 |
1.6 |
1.2 |
0.5 |
46/2.0 |
2.1 |
2.3 |
36.5 |
40.8 |
2241 |
4049 |
2989 |
4797 |
|
|
3×120 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.2 |
2.4 |
39.8 |
44.1 |
2617 |
4895 |
3435 |
5713 |
|
|
3×150 |
36 |
1.8 |
1.2 |
0.5 |
43/2.5 |
2.3 |
2.5 |
42.4 |
47.8 |
3019 |
5846 |
4258 |
7085 |
|
|
3×185 |
36 |
2 |
1.4 |
0.5 |
50/2.5 |
2.5 |
2.7 |
48.8 |
54.2 |
3783 |
7264 |
5219 |
8700 |
|
|
3×240 |
60 |
2.2 |
1.6 |
0.5 |
58/2.5 |
2.8 |
2.9 |
56 |
61.3 |
4790 |
9390 |
6444 |
11044 |
|
|
3×300 |
60 |
2.4 |
1.6 |
0.5 |
61/2.5 |
2.9 |
3.1 |
59.3 |
64.7 |
5594 |
11345 |
7458 |
13209 |
|
|
Four Cores with Reduced Neutral |
||||||||||||||
|
3×35+16 |
16-7 |
1.2-1 |
1 |
0.2 |
43/1.6 |
1.9 |
2 |
28.5 |
31.3 |
1107 |
1528 |
1705 |
2469 |
|
|
3×50+25 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
40/2.0 |
2.0 |
2.1 |
32.2 |
36.1 |
1410 |
2044 |
2326 |
3388 |
|
|
3×70+35 |
18-16 |
1.4-1.2 |
1.2 |
0.2 |
44/2.0 |
2.0 |
2.2 |
35.2 |
39.3 |
1733 |
2801 |
2762 |
4285 |
|
|
3×95+50 |
36-18 |
1.6-1.4 |
1.2 |
0.5 |
41/2.5 |
2.3 |
2.5 |
42.5 |
46.3 |
2656 |
3820 |
3816 |
5925 |
|
|
3×120+70 |
36-18 |
1.6-1.4 |
1.4 |
0.5 |
45/2.5 |
2.4 |
2.6 |
45.6 |
49.4 |
3137 |
4777 |
4391 |
7103 |
|
|
3×150+70 |
36-18 |
1.8-1.4 |
1.4 |
0.5 |
49/2.5 |
2.6 |
2.7 |
49.9 |
53.6 |
3660 |
5709 |
5043 |
8272 |
|
|
3×185+95 |
36-36 |
2-1.6 |
1.4 |
0.5 |
55/2.5 |
2.6 |
2.9 |
54.5 |
58.5 |
3445 |
7171 |
5902 |
9987 |
|
|
3×240+120 |
60-36 |
2.2-1.6 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3.1 |
61.6 |
65.3 |
5441 |
9272 |
7174 |
12552 |
|
|
3×300+150 |
60-36 |
1.4-1.8 |
1.6 |
0.5 |
67/2.5 |
3.8 |
3.2 |
65.9 |
69.6 |
6494 |
11546 |
8355 |
15067 |
|
|
Four Cores |
||||||||||||||
|
4×25 |
16 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.9 |
25.3 |
28 |
934 |
1576 |
1450 |
2092 |
|
|
4×35 |
16 |
1.2 |
1 |
0.2 |
41/1.6 |
1.8 |
1.9 |
27.4 |
30.2 |
1120 |
2017 |
1681 |
2578 |
|
|
4×50 |
18 |
1.4 |
1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.6 |
35.6 |
1454 |
2658 |
2336 |
3540 |
|
|
4×70 |
18 |
1.4 |
1.2 |
0.5 |
43/2.0 |
2.1 |
2.2 |
36.3 |
39 |
2183 |
3916 |
2840 |
4573 |
|
|
4×95 |
36 |
1.6 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.4 |
40.6 |
44.1 |
2748 |
5160 |
3545 |
5957 |
|
|
4×120 |
36 |
1.6 |
1.4 |
0.5 |
42/2.5 |
2.4 |
2.5 |
43.9 |
47.2 |
3237 |
6214 |
4334 |
7372 |
|
|
4×150 |
36 |
1.8 |
1.4 |
0.5 |
48/2.5 |
2.5 |
2.6 |
48.3 |
52 |
3853 |
7622 |
5148 |
8917 |
|
|
4×185 |
36 |
2 |
1.6 |
0.5 |
54/2.5 |
2.7 |
2.8 |
54.3 |
57.6 |
4756 |
9323 |
6132 |
10774 |
|
|
4×240 |
60 |
2.2 |
1.6 |
0.5 |
59/2.5 |
2.9 |
3 |
59.2 |
62.9 |
5774 |
11906 |
7374 |
13506 |
|
|
4×300 |
60 |
2.4 |
1.6 |
0.5 |
65/2.5 |
3 |
3.2 |
64.3 |
68.1 |
6922 |
14589 |
8624 |
16291 |
|
5)600/1000V, Multi Cores, Circular Compacted Al or Cu/PVC/PVC Armoured Power Cable
|
Cross Section of Conductor |
No. of Wires |
Thickness of Insulation |
Thickness of Inner Sheath |
Thickness of Steel Tape |
No./Dia. Of Steel Wires |
Thickness of Sheath |
Overall Diameter |
Approx. Net Weight |
|||||
|
STA |
SWA |
||||||||||||
|
STA |
SWA |
STA |
SWA |
STA |
SWA |
Al Conductor |
Cu Conductor |
Al Conductor |
Cu Conductor |
||||
|
mm2 |
– |
mm |
mm |
mm |
No./mm |
mm |
mm |
mm |
mm |
kg/km |
kg/km |
kg/km |
kg/km |
|
Three Cores |
|||||||||||||
|
3×10 |
7 |
1 |
1 |
0.2 |
35/1.25 |
1.8 |
1.8 |
19.4 |
21.5 |
494 |
679 |
988 |
1172 |
|
3×16 |
7 |
1 |
1 |
0.2 |
32/1.6 |
1.8 |
1.8 |
21.5 |
24.3 |
604 |
895 |
1051 |
1343 |
|
3×25 |
7 |
1.2 |
1 |
0.2 |
38/1.6 |
1.8 |
1.8 |
25 |
27.9 |
791 |
1252 |
1329 |
1790 |
|
3×35 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
950 |
1595 |
1551 |
2196 |
|
3×50 |
19 |
1.4 |
1.1 |
0.2 |
39/2.0 |
2 |
2.1 |
31.3 |
35.2 |
1213 |
2079 |
2128 |
2994 |
|
3×70 |
19 |
1.4 |
1.2 |
0.5 |
45/2.0 |
2.1 |
2.2 |
35.6 |
40.1 |
1567 |
2894 |
2678 |
4005 |
|
3×95 |
19 |
1.6 |
1.3 |
0.5 |
42/2.5 |
2.3 |
2.4 |
42 |
46.2 |
2449 |
4188 |
3689 |
5428 |
|
3×120 |
37 |
1.6 |
1.3 |
0.5 |
45/2.5 |
2.4 |
2.5 |
45.3 |
49.6 |
2823 |
5014 |
4174 |
6364 |
|
3×150 |
37 |
1.8 |
1.4 |
0.5 |
49/2.5 |
2.5 |
2.7 |
48.9 |
53.2 |
3327 |
6069 |
4795 |
7537 |
|
3×185 |
37 |
2 |
1.5 |
0.5 |
56/2.5 |
2.7 |
2.8 |
54.5 |
58.7 |
4038 |
7371 |
5686 |
9019 |
|
3×240 |
61 |
2.2 |
1.6 |
0.5 |
63/2.5 |
2.9 |
3.1 |
61.4 |
65.2 |
4994 |
9457 |
6862 |
11325 |
|
3×300 |
61 |
2.4 |
1.7 |
0.5 |
70/2.5 |
3.2 |
3.3 |
67.9 |
71.7 |
6022 |
11564 |
8101 |
13643 |
|
3×400 |
61 |
2.6 |
1.9 |
0.5 |
62/3.15 |
3.4 |
3.6 |
75.4 |
80.5 |
7350 |
14543 |
10535 |
17728 |
|
Four Cores |
|||||||||||||
|
4×10 |
7 |
1 |
1 |
0.2 |
39/1.25 |
1.8 |
1.8 |
20.9 |
23 |
552 |
798 |
1073 |
1319 |
|
4×16 |
7 |
1 |
1 |
0.2 |
35/1.6 |
1.8 |
1.8 |
23.3 |
26.1 |
723 |
1110 |
1213 |
1601 |
|
4×25 |
7 |
1.2 |
1 |
0.2 |
42/1.6 |
1.8 |
1.9 |
27.2 |
30.2 |
959 |
1573 |
1559 |
2173 |
|
4×35 |
7 |
1.2 |
1 |
0.2 |
37/2.0 |
1.9 |
2 |
29.7 |
33.6 |
1140 |
2000 |
2006 |
2866 |
|
4×50 |
19 |
1.4 |
1.2 |
0.2 |
44/2.0 |
2.1 |
2.2 |
34.6 |
38.4 |
1524 |
2679 |
2541 |
3696 |
|
4×70 |
19 |
1.4 |
1.2 |
0.5 |
50/2.0 |
2.3 |
2.3 |
40.5 |
43.7 |
2338 |
4107 |
3187 |
4956 |
|
4×95 |
19 |
1.6 |
1.2 |
0.5 |
46/2.5 |
2.4 |
2.6 |
45.9 |
50.2 |
2955 |
5274 |
4325 |
6644 |
|
4×120 |
37 |
1.6 |
1.4 |
0.5 |
51/2.5 |
2.6 |
2.7 |
50 |
54.2 |
3466 |
6387 |
4568 |
7888 |
|
4×150 |
37 |
1.8 |
1.4 |
0.5 |
55/2.5 |
2.7 |
2.8 |
53.8 |
58.1 |
4144 |
7800 |
5772 |
9428 |
|
4×185 |
37 |
2 |
1.6 |
0.5 |
62/2.5 |
2.9 |
3 |
60.2 |
64.5 |
4987 |
9430 |
6822 |
11266 |
|
4×240 |
61 |
2.2 |
1.6 |
0.5 |
70/2.5 |
3.1 |
3.3 |
67.7 |
71.5 |
6161 |
12111 |
8233 |
14184 |
|
4×300 |
61 |
2.4 |
1.6 |
0.5 |
61/3.15 |
3.4 |
3.5 |
74.7 |
78.8 |
7346 |
14735 |
10305 |
17694 |
We are China Direct Manufacture PVC Insulated and Sheathed Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Cable Products
PE Insulated Steel Wire Armoured Cable (4-120+1-70)
Aerial Bundle Cable ABC Cable Hot Selling
8000 Series Aluminum Alloy XLPE Insulation Concentric Cable, Electric Wire, Electric Cable
4X95mm2 Aluminimum Conductor Aerial Bundle Power Cable Specification
HS Code for Underwater 70mm2 Power Cable
Hebei Huatong Cables Supply Ht Interlocke Armor Cu XLPE Aluminum Conductor Teck90 Cable
Popular Direct Manufacture PVC Insulated and Sheathed Power Cable Products
Popular jpcable99 Products
Hot Seller Duplex Service Drop Wire
AAC Ant/Bee/Locust/Centipede All Aluminium Conducto
New ABC Cable Self-Supporting Cable
(Stranded) Galvanized Steel Wire
8.7/15kv Copper Conductor Cable XLPE Insulated Unarmoured Power Cable
Popular Power Cable Products
Hot Selling Flexible Electrical Power Cable PVC Wire
(N) Ym (ST) -J Cable with Shield Drain Wire
2021 Hot Selling XLPE Insulated Power Cable, Electric Cable
LSZH Lsoh Ls0h Lsfh Ohls XLPE Insulated Sheathed Transmission and Distribution Electric Power Cable
600V Nyy 4*25mm2 Type Cu/PVC/PVC Electrical Cable
Tags: Cable, Direct Manufacture PVC Insulated and Sheathed Power Cable, jpcable99, Power Cable