11kv 3X240mm2 XLPE Power Cable
11kv 3X240mm2 XLPE Power Cable image
Get Latest Price Request a quote
Basic Info.
Product Description
Application
Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Property
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
FAQ
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China
2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;
3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS
4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.
5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.
6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.
7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.
8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.
Specification:
| 7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | 6 | 3.4 | 0.1 | 2.1 | 38.7 | 1.3 | 1.75 | 1.2 | 0.727 |
| 35 | 6.9 | 3.4 | 0.1 | 2.2 | 40.9 | 1.47 | 2.22 | 0.868 | 0.524 |
| 50 | 8.2 | 3.4 | 0.1 | 2.3 | 43.9 | 1.7 | 2.5 | 0.641 | 0.387 |
| 70 | 9.7 | 3.4 | 0.1 | 2.4 | 47.3 | 2.02 | 3.25 | 0.443 | 0.268 |
| 95 | 11.3 | 3.4 | 0.1 | 2.5 | 51 | 2.42 | 4.12 | 0.32 | 0.193 |
| 120 | 12.8 | 3.4 | 0.1 | 2.6 | 54.4 | 2.79 | 4.95 | 0.253 | 0.153 |
| 150 | 14.2 | 3.4 | 0.1 | 2.7 | 57.6 | 3.17 | 5.87 | 0.206 | 0.124 |
| 185 | 15.9 | 3.4 | 0.1 | 2.8 | 61.5 | 3.69 | 7.06 | 0.164 | 0.0991 |
| 240 | 18.3 | 3.4 | 0.1 | 2.9 | 66.9 | 4.38 | 8.82 | 0.125 | 0.0754 |
| 300 | 20.4 | 3.4 | 0.1 | 3.1 | 71.8 | 5.11 | 10.68 | 0.1 | 0.0601 |
| 400 | 23.2 | 3.4 | 0.1 | 3.3 | 78.3 | 6.24 | 13.32 | 0.0778 | 0.047 |
| 500 | 26.4 | 3.4 | 0.1 | 3.5 | 86.4 | 7.63 | 16.5 | 0.0605 | 0.0366 |
| 8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | Ω/km | Ω/km | |
| 25 | 6 | 4.5 | 0.1 | 2.3 | 43.9 | 1.57 | 2.02 | 0.927 | 0.727 |
| 35 | 6.9 | 4.5 | 0.1 | 2.4 | 46 | 1.75 | 2.38 | 0.668 | 0.524 |
| 50 | 8.2 | 4.5 | 0.1 | 2.4 | 48.8 | 2 | 2.85 | 0.4936 | 0.387 |
| 70 | 9.7 | 4.5 | 0.1 | 2.5 | 52.3 | 2.34 | 3.57 | 0.342 | 0.268 |
| 95 | 11.3 | 4.5 | 0.1 | 2.6 | 55.9 | 2.75 | 4.45 | 0.2464 | 0.193 |
| 120 | 12.8 | 4.5 | 0.1 | 2.7 | 59.4 | 3.16 | 5.32 | 0.1955 | 0.153 |
| 150 | 14.2 | 4.5 | 0.1 | 2.8 | 62.6 | 3.57 | 6.27 | 0.1587 | 0.124 |
| 185 | 15.9 | 4.5 | 0.1 | 2.9 | 66.4 | 4.07 | 7.45 | 0.1271 | 0.0991 |
| 240 | 18.3 | 4.5 | 0.1 | 3.1 | 72 | 4.82 | 9.25 | 0.0976 | 0.0754 |
| 300 | 20.4 | 4.5 | 0.1 | 3.3 | 77 | 5.71 | 11.28 | 0.0778 | 0.0601 |
| 400 | 23.2 | 4.5 | 0.1 | 3.4 | 83.2 | 6.78 | 13.86 | 0.0615 | 0.047 |
| 500 | 26.4 | 4.5 | 0.1 | 3.5 | 91.1 | 8.2 | 17.32 | 0.0487 | 0.0366 |
| 9)12/20(24)kV, 12.7/22(24)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm 2 | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | – | ||||||||
| 35 | 6.9 | 5.5 | 0.1 | 2.4 | 50.3 | 2 | 2.63 | 0.868 | 0.668 |
| 50 | 8.2 | 5.5 | 0.1 | 2.5 | 53.3 | 2.26 | 3.11 | 0.641 | 0.4936 |
| 70 | 9.7 | 5.5 | 0.1 | 2.6 | 56.8 | 2.62 | 3.85 | 0.443 | 0.342 |
| 95 | 11.3 | 5.5 | 0.1 | 2.8 | 60.6 | 3.07 | 4.77 | 0.32 | 0.2464 |
| 120 | 12.8 | 5.5 | 0.1 | 2.9 | 64.1 | 3.49 | 5.65 | 0.253 | 0.1955 |
| 150 | 14.2 | 5.5 | 0.1 | 3 | 67.3 | 3.91 | 6.61 | 0.206 | 0.1587 |
| 185 | 15.9 | 5.5 | 0.1 | 3.1 | 71.2 | 4.44 | 7.81 | 0.164 | 0.1271 |
| 240 | 18.3 | 5.5 | 0.1 | 3.3 | 76.8 | 5.21 | 9.64 | 0.125 | 0.0976 |
| 300 | 20.4 | 5.5 | 0.1 | 3.3 | 81.3 | 6.1 | 11.66 | 0.1 | 0.0778 |
| 400 | 23.2 | 5.5 | 0.1 | 3.5 | 87.7 | 7.2 | 14.28 | 0.0778 | 0.0615 |
| 500 | 26.4 | 5.5 | 0.1 | 3.8 | 96 | 9.15 | 17.8 | 0.0605 | 0.0487 |
| 10)18/30(36)kV,19/33(36)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable | |||||||||
| Normal Cross Section of Conductor | Normal Diameter of Conductor | Normal Thickness of Insulation | Normal Thickness of | Normal Thickness of Outer Sheath | Approx. | Approx. Net Weight | Max. D.C. Resistance of Conductor at 20 | ||
| Copper Tape | Overall Dia. | Al Conductor | Cu Conductor | Al Conductor | Cu Conductor | ||||
| mm 2 | mm | mm | mm | mm | mm | kg/m | kg/m | Ω/km | Ω/km |
| 25 | |||||||||
| 35 | |||||||||
| 50 | 8.2 | 8 | 0.1 | 2.9 | 64.9 | 3.02 | 3.87 | 0.641 | 0.4936 |
| 70 | 9.7 | 8 | 0.1 | 3 | 68.4 | 3.42 | 4.65 | 0.443 | 0.342 |
| 95 | 11.3 | 8 | 0.1 | 3.1 | 72 | 3.89 | 5.59 | 0.32 | 0.2464 |
| 120 | 12.8 | 8 | 0.1 | 3.3 | 75.7 | 4.39 | 6.54 | 0.253 | 0.1955 |
| 150 | 14.2 | 8 | 0.1 | 3.3 | 78.7 | 4.85 | 7.55 | 0.206 | 0.1587 |
| 185 | 15.9 | 8 | 0.1 | 3.4 | 82.6 | 5.42 | 8.79 | 0.164 | 0.1271 |
| 240 | 18.3 | 8 | 0.1 | 3.5 | 88 | 6.22 | 10.66 | 0.125 | 0.0976 |
| 300 | 20.4 | 8 | 0.1 | 3.7 | 92.9 | 7.2 | 12.77 | 0.1 | 0.0778 |
| 400 | 23.2 | 8 | 0.1 | 3.9 | 99.3 | 8.38 | 15.46 | 0.0778 | 0.0615 |
| 500 | 26.4 | 8 | 0.1 | 4.2 | 107.6 | 10.15 | 18.85 | 0.0605 | 0.0487 |
We are China 11kv 3X240mm2 XLPE Power Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 11kv 3X240mm2 XLPE Power Cable Products
Popular Cable Products
Standard Cable Overhead Aerial Bundled Cable XLPE Insulated ABC Power Cable
0.6/1kv Low Voltage Copper Core XLPE Insulate Electric Power Cable
11kv XLPE Insulated Power Cable Steel Wire Armoured Power Cable
Jgp High Voltage Three Cores Cable Cleat Hight Quantity
High Voltage PVC Insulation Power Cable Electric Wire
110kv 3 Core Steel Tape Armoured 300mm2 Al XLPE PVC Power Cable
Popular jpcable99 Products
XLPE Insulated Armoured Marine Cable
150mm2 Copper/Aluminum Conductor XLPE Insulated Power Cable
12/20kv XLPE/Swa/PVC Power Cable 1*50 1*70
Mv XLPE Insulated Unarmoured Power Cable
1.5mm2 Copper Conductor PVC Insulated Power Cable
600V Quadruplex Conductor Urd ABC Cable
Popular XLPE Cable Products
Medium Voltage N2xsy / Na2xsy XLPE Insulation PVC Sheath Power Cable
1X16+16 Overhead ABC Cable Aluminium Conductor Jinshui
19/33kV XLPE CU 1 Core 630mm2 Aluminum Wire Armoured IEC 60502-2 Power Cable
All Aluminium Conductors Type 8 PVC Insulation (AAC/PVC)
XLPE Insulated PVC Sheathed Underground Electric Wire Cable
CSA 1 Kv Aluminum/Copper 500 Mcm XLPE RW90 Rwu90 Cable
Tags: 11kv 3X240mm2 XLPE Power Cable, Cable, jpcable99, XLPE Cable