Thhn/Thwn Single Core Copper Conductor Electric Cable Wire
Thhn/Thwn Single Core Copper Conductor Electric Cable Wire image
Get Latest Price Request a quote
- Overview
- Product Description
- Detailed Photos
- Packaging & Shipping
- Testing
- Our Equipments
- FAQ
Basic Info.
Packaging & Delivery
Product Description
Applications:
1.Type THHN / THWN / THW / TW Cable is intended for general purpose applications as defined by the National Electrical Code (NEC)Type THHN-THWN-2 is permitted for new construction or rewiring for 60 volt applications. Applications requiring Type THHN or THWN.
a. THHN wire: It indicates a single or stranded conductor having flame-retardant and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 90°C dry only.THHN cable may also be used for wiring of machine tools, control circuits or on certain appliances.
b. THWN wire: It Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation with a jacket of extruded nylon or equivalent material. The wire is rated 75°C wet or dry. THWN cable is typically used for installation in conduit, machine tools, controlled circuits, or other general purpose wiring.
c.THW wire- Indicates a single conductor having flame-retardant, moisture and heat-resistant thermoplastic insulation. The wire is rated 75°C wet or dry.THW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.
d.TW wire- Indicates a single conductor having flame-retardant, moisture-resistant thermoplastic insulation. The wire is rated 60°C wet or dry.TW cable and wires are used generally in building wiring, feeder and branch circuits, and internal secondary industrial distribution.
SPECIFICATIONS
| Conductor | Insulation Thickness | Jacket Thickness | Cable Dimensions | Approx. Weight | Allowable Ampacity* (Amps) 30°C Ambient | |||||||
| Size (AWG or kcmil) | # of Strands | inches | mm | inches | mm | inches | mm | lb/1000ft | kg/km | 60°C | 75°C | 90°C |
| 14 | 1 | 0.015 | 0.38 | 0.004 | 0.10 | 0.102 | 2.59 | 15 | 23 | 15 | 20 | 25 |
| 12 | 1 | 0.015 | 0.38 | 0.004 | 0.10 | 0.119 | 3.02 | 23 | 34 | 20 | 25 | 30 |
| 10 | 1 | 0.020 | 0.51 | 0.004 | 0.10 | 0.150 | 3.81 | 37 | 55 | 30 | 35 | 40 |
| 14 | 19 | 0.015 | 0.38 | 0.004 | 0.10 | 0.109 | 2.77 | 15 | 23 | 15 | 20 | 25 |
| 12 | 19 | 0.015 | 0.38 | 0.004 | 0.10 | 0.128 | 3.25 | 24 | 36 | 20 | 25 | 30 |
| 10 | 19 | 0.020 | 0.51 | 0.004 | 0.10 | 0.161 | 4.09 | 38 | 57 | 30 | 35 | 40 |
| 8 | 19 | 0.030 | 0.76 | 0.005 | 0.13 | 0.213 | 5.41 | 63 | 93 | 40 | 50 | 55 |
| 6 | 19 | 0.030 | 0.76 | 0.005 | 0.13 | 0.249 | 6.32 | 95 | 141 | 55 | 65 | 75 |
| 4 | 19 | 0.040 | 1.02 | 0.006 | 0.15 | 0.318 | 8.08 | 152 | 227 | 70 | 85 | 95 |
| 3 | 19 | 0.040 | 1.02 | 0.006 | 0.15 | 0.346 | 8.79 | 189 | 281 | 85 | 100 | 115 |
| 2 | 19 | 0.040 | 1.02 | 0.006 | 0.15 | 0.378 | 9.60 | 234 | 349 | 95 | 115 | 130 |
| 1 | 19 | 0.050 | 1.27 | 0.007 | 0.18 | 0.435 | 11.0 | 299 | 446 | 110 | 130 | 145 |
| 1/0 | 19 | 0.050 | 1.27 | 0.007 | 0.18 | 0.474 | 12.0 | 372 | 553 | 125 | 150 | 170 |
| 2/0 | 19 | 0.050 | 1.27 | 0.007 | 0.18 | 0.518 | 13.2 | 462 | 687 | 145 | 175 | 195 |
| 3/0 | 19 | 0.050 | 1.27 | 0.007 | 0.18 | 0.568 | 14.4 | 575 | 856 | 165 | 200 | 225 |
| 4/0 | 19 | 0.050 | 1.27 | 0.007 | 0.18 | 0.624 | 15.8 | 718 | 1068 | 195 | 230 | 260 |
| 250 | 37 | 0.060 | 1.52 | 0.008 | 0.20 | 0.694 | 17.6 | 851 | 1266 | 215 | 255 | 290 |
| 300 | 37 | 0.060 | 1.52 | 0.008 | 0.20 | 0.747 | 18.9 | 1012 | 1506 | 240 | 285 | 320 |
| 350 | 37 | 0.060 | 1.52 | 0.008 | 0.20 | 0.797 | 20.2 | 1174 | 1747 | 260 | 310 | 350 |
| 400 | 37 | 0.060 | 1.52 | 0.008 | 0.20 | 0.842 | 21.4 | 1334 | 1985 | 280 | 335 | 380 |
| 500 | 37 | 0.060 | 1.52 | 0.008 | 0.20 | 0.926 | 23.5 | 1655 | 2462 | 320 | 380 | 430 |
| 600 | 61 | 0.070 | 1.78 | 0.009 | 0.23 | 1.024 | 26.0 | 1987 | 2957 | 350 | 420 | 475 |
| 750 | 61 | 0.070 | 1.78 | 0.009 | 0.23 | 1.126 | 28.6 | 2464 | 3667 | 400 | 475 | 535 |
| 1000 | 61 | 0.070 | 1.78 | 0.009 | 0.23 | 1.275 | 32.4 | 3257 | 4847 | 455 | 545 | 615 |
Building Wire Construction:
Insulation: PVC (Poly Vinyl Chloride) with Secondary Nylon Jacket
Conductor: Annealed solid or stranded copper wires (copper or CCA)
Voltage Rating: 600 Volts.
Standard:
Built to CSA C22.2 No.75
THHN or THWN-2* or MTW wire (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.
Nylon Jacket PVC Building Electric Wire,THHN-THWN-THW-TW specifications(data sheet,table,full form)
1.Are you a manufacturer or trading company?
We are a professional manufacturer.We can control your order from the first
beginning to the last.
Welcome to visit us.We’ll pick you up in Zhengzhou
2. How can I get a sample to test your quality?
The samples are free for you.New clients are expected to pay for the courier
cost.
3.What’s your Minimum Order Quantity?
Normally 1000m.How ever the cable is very heavy.
You’d better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4.Can I get a discount?
It depends on your quantity,We can make a discount and afford the freight.
Pls kindly contact us.
5. Does your company accept OEM production?
Yes, could print your company name we even custom the quality card to
promote your company.
We are China Thhn/Thwn Single Core Copper Conductor Electric Cable Wire manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Copper Wire Products
4*16mm2 XLPE/PVC Insulated LV/Hv ABC Cable Aerial Bundled Overhead Cable
Transformer Cable Mv90 Mv105 5kv 8kv UL Cable Electrical Power Wire
Manufacturer Single Core 1.5mm2 Copper Electrical Cable Wire
UL Certified 600V Home Use Electric Wire Thhn
Electrical Wire Flexible Cable for Building Decoration
Popular PVC Insulated Wire 1.5mm2
Popular Electrical Wire Products
PVC Jacket and Copper Conductor Material Power Cable
Fire Resistant Electric Cable Wire PVC Insulated Electric Building Wire
IEC BS Standard 4 Core 4mm PVC Cable XLPE Power Cable for Engineering Project and Bidding Project.
Low Smoke Halogen Free Xlpo Insulation UV Resistant DC 1500V Solar Panel System Cable 240mm
4mm2/6mm2 Copper Conductor PVC Electric Wire for Building or Constrction
Popular Thhn/Thwn Single Core Copper Conductor Electric Cable Wire Products
Popular zmlcable Products
Cable Multiconductor Control Cable PVC/Swa/PVC 2.5mm2 X 19 Cores,
China Factory Manufacture 4 AWG Silicone Rubber Insulated Copper Welding Power Cable
Factory Price Galvanized Steel Wire Strand/Stay Wire
ABC Cables Service Drop Cables Aluminium Conductor XLPE Insulated Power Cable
Medium Voltage Single Core XLPE Insulated Underground Power Cable
Super Sell Electrical Wire Silicone Rubber Cable 26 24 20 18 16AWG UL3122 Fiberglass
Tags: Copper Wire, Electrical Wire, Thhn/Thwn Single Core Copper Conductor Electric Cable Wire, zmlcable