Overhead Transmission Line Aerial Bundle Cables ABC Cable
Overhead Transmission Line Aerial Bundle Cables ABC Cable image
Get Latest Price Request a quote
- Overview
- Product Description
- Product Parameters
- TESTING
- Certifications
- Packaging & Shipping
- Customer Visit
- Company Profile
- FAQ
Basic Info.
Product Description
ONE-STOP SOLUTIONS FOR WIRES&CABLES – HENAN UME CABLE CO., LTD
Over 30 years of Wires and Cables manufacture experience and Export to over 50 countries.
1. Applications
They are widely used in temporary power distribution to street lighting and secondary pole-pole service cables. ABC wires feature light stranded aluminum conductors, both single-core and multi-cores, covered with XLPE/PE/PVC insulation. They are more commonly used in temporary power installations such as an on-base building. They are often referred to as bare conductors As insulated cables. These cables are installed and separated by air gaps but where sparks and shorts in the event of high winds may cause resulting bushfires in dry climates or risk nearby property.
2. Standard
ABC Cable NFC 33-209
ABC Cable BS 7870
ABC CABLE AS/NZS 3560.1
ABC Cable GB 12527
ABC Cable NFC 33-209
| No. of Conductor and Cross Section Area |
Phase Core | Neutral Core | Street Lighting Core | Complete Cable | ||||||||||
| No. and Section Area |
No. of Wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
No. and Section Area |
No. of Wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
No. and Section area |
No. of Wires | Diameter of conductor |
Insulation Thickness |
Overall Diameter (Approx.) |
Weight (Approx.) |
|
| mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km |
| 2×16 | 2×16 | 7 | 4.8 | 1.2 | – | – | – | – | – | – | – | – | 14.2 | 126 |
| 2×25 | 2×25 | 7 | 6.0 | 1.4 | – | – | – | – | – | – | – | – | 17.6 | 194 |
| 2×35 | 2×35 | 7 | 7.0 | 1.6 | – | – | – | – | – | – | – | – | 20.4 | 266 |
| 2×50 | 2×50 | 7 | 8.1 | 1.6 | – | – | – | – | – | – | – | – | 22.6 | 341 |
| 4×16 | 4×16 | 7 | 4.8 | 1.2 | – | – | – | – | – | – | – | – | 17.2 | 252 |
| 4×25 | 4×25 | 7 | 6.0 | 1.4 | – | – | – | – | – | – | – | – | 21.2 | 388 |
| 4×35 | 4×35 | 7 | 7.0 | 1.6 | – | – | – | – | – | – | – | – | 24.6 | 533 |
| 3×25+54.6 | 3×25 | 7 | 6.0 | 1.4 | 1×54.6 | 7 | 9.45 | 1.6 | – | – | – | – | 23.6 | 496 |
| 3×25+54.6+1×16 | 3×25 | 7 | 6.0 | 1.4 | 1×54.6 | 7 | 9.45 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 24.9 | 560 |
| 3×25+54.6+2×16 | 3×25 | 7 | 6.0 | 1.4 | 1×54.6 | 7 | 9.45 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 26.6 | 624 |
| 3×35+54.6 | 3×35 | 7 | 7.0 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | – | – | – | – | 26.1 | 604 |
| 3×35+54.6+1×16 | 3×35 | 7 | 7.0 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 27.2 | 668 |
| 3×35+54.6+2×16 | 3×35 | 7 | 7.0 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 28.7 | 732 |
| 3×50+54.6 | 3×50 | 7 | 8.1 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | – | – | – | – | 28.1 | 716 |
| 3×50+54.6+1×16 | 3×50 | 7 | 8.1 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 28.9 | 780 |
| 3×50+54.6+2×16 | 3×50 | 7 | 8.1 | 1.6 | 1×54.6 | 7 | 9.45 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 30.3 | 844 |
| 3×70+54.6 | 3×70 | 12 | 10.0 | 1.8 | 1×54.6 | 7 | 9.45 | 1.6 | – | – | – | – | 32.2 | 940 |
| 3×70+54.6+1×16 | 3×70 | 12 | 10.0 | 1.8 | 1×54.6 | 7 | 9.45 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 32.7 | 1004 |
| 3×70+54.6+2×16 | 3×70 | 12 | 10.0 | 1.8 | 1×54.6 | 7 | 9.45 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 33.8 | 1068 |
| 3×70+54.6+1×25 | 3×70 | 12 | 10.0 | 1.8 | 1×54.6 | 7 | 9.45 | 1.6 | 1×25 | 7 | 6.0 | 1.4 | 33.6 | 1038 |
| 3×70+54.6+2×25 | 3×70 | 12 | 10.0 | 1.8 | 1×54.6 | 7 | 9.45 | 1.6 | 2×25 | 7 | 6.0 | 1.4 | 35.5 | 1137 |
| 3×70+70 | 3×70 | 12 | 10.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | – | – | – | – | 32.1 | 970 |
| 3×70+70+1×16 | 3×70 | 12 | 10.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 1×16 | 7 | 4.8 | 1.2 | 32.5 | 1035 |
| 3×70+70+2×16 | 3×70 | 12 | 10.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 2×16 | 7 | 4.8 | 1.2 | 33.6 | 1099 |
| 3×95+70 | 3×95 | 19 | 11.7 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | – | – | – | – | 35.6 | 1212 |
| 3×95+70+1×16 | 3×95 | 19 | 11.7 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 1×16 | 7 | 4.8 | 1.2 | 35.7 | 1276 |
| 3×95+70+2×16 | 3×95 | 19 | 11.7 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 2×16 | 7 | 4.8 | 1.2 | 36.6 | 1340 |
| 3×120+70 | 3×120 | 19 | 13.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | – | – | – | – | 38.0 | 1439 |
| 3×120+70+1×16 | 3×120 | 19 | 13.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 1×16 | 7 | 4.8 | 1.2 | 37.8 | 1503 |
| 3×120+70+2×16 | 3×120 | 19 | 13.0 | 1.8 | 1×70 | 7 | 10.20 | 1.5 | 2×16 | 7 | 4.8 | 1.2 | 38.6 | 1567 |
| 3×150+70 | 3×150 | 19 | 14.4 | 1.7 | 1×70 | 7 | 10.20 | 1.5 | – | – | – | – | 40.2 | 1650 |
| 3×150+70+1×16 | 3×150 | 19 | 14.4 | 1.7 | 1×70 | 7 | 10.20 | 1.5 | 1×16 | 7 | 4.8 | 1.2 | 39.8 | 1714 |
| 3×150+70+2×16 | 3×150 | 19 | 14.4 | 1.7 | 1×70 | 7 | 10.20 | 1.5 | 2×16 | 7 | 4.8 | 1.2 | 40.4 | 1778 |
| 3×120+95 | 3×120 | 19 | 13.0 | 1.8 | 1×95 | 19 | 12.50 | 1.6 | – | – | – | – | 39.5 | 1526 |
| 3×120+95+1×16 | 3×120 | 19 | 13.0 | 1.8 | 1×95 | 19 | 12.50 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 39.5 | 1590 |
| 3×120+95+2×16 | 3×120 | 19 | 13.0 | 1.8 | 1×95 | 19 | 12.50 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 39.8 | 1654 |
| 3×150+95 | 3×150 | 19 | 14.4 | 1.7 | 1×95 | 19 | 12.50 | 1.6 | – | – | – | – | 41.7 | 1736 |
| 3×150+95+1×16 | 3×150 | 19 | 14.4 | 1.7 | 1×95 | 19 | 12.50 | 1.6 | 1×16 | 7 | 4.8 | 1.2 | 41.7 | 1800 |
| 3×150+95+2×16 | 3×150 | 19 | 14.4 | 1.7 | 1×95 | 19 | 12.50 | 1.6 | 2×16 | 7 | 4.8 | 1.2 | 41.6 | 1865 |
ABC Cable BS 7870
| No. of Core & Size |
Phase Core | Neutral Core | Complete Cable | |||||||
| No. & Section Area |
No. of wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
No. & Section Area |
No. of Wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
Overall Diameter (Approx.) |
Weight (Approx.) |
|
| mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km |
| 1×25 | 1×25 | 7 | 6.0 | 1.3 | – | – | – | – | 8.6 | 96 |
| 1×35 | 1×35 | 7 | 7.0 | 1.3 | – | – | – | – | 9.6 | 126 |
| 1×50 | 1×50 | 19 | 8.4 | 1.5 | – | – | – | – | 11.4 | 183 |
| 1×70 | 1×70 | 19 | 10.0 | 1.5 | – | – | – | – | 13.0 | 236 |
| 1×95 | 1×95 | 19 | 11.6 | 1.7 | – | – | – | – | 15.0 | 323 |
| 1×120 | 1×120 | 19 | 13.0 | 1.7 | – | – | – | – | 16.4 | 399 |
| 2×25 | 1×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 17.2 | 192 |
| 2×35 | 1×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 19.2 | 252 |
| 2×50 | 1×50 | 19 | 8.4 | 1.5 | 1×50 | 19 | 8.4 | 1.5 | 22.8 | 365 |
| 2×70 | 1×70 | 19 | 10.0 | 1.5 | 1×70 | 19 | 10.0 | 1.5 | 26.0 | 472 |
| 2×95 | 1×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 30.0 | 645 |
| 2×120 | 1×120 | 19 | 13.0 | 1.7 | 1×120 | 19 | 13.0 | 1.7 | 32.8 | 798 |
| 3×25 | 2×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 18.5 | 288 |
| 3×35 | 2×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 20.6 | 378 |
| 3×50 | 2×50 | 19 | 8.4 | 1.5 | 1×50 | 19 | 8.4 | 1.5 | 24.5 | 548 |
| 3×70 | 2×70 | 19 | 10.0 | 1.5 | 1×70 | 19 | 10.0 | 1.5 | 28.0 | 708 |
| 3×95 | 2×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 32.3 | 968 |
| 3×120 | 2×120 | 19 | 13.0 | 1.7 | 1×120 | 19 | 13.0 | 1.7 | 35.3 | 1196 |
| 4×25 | 3×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 20.7 | 384 |
| 4×35 | 3×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 23.1 | 504 |
| 4×50 | 3×50 | 19 | 8.4 | 1.5 | 1×50 | 19 | 8.4 | 1.5 | 27.5 | 731 |
| 4×70 | 3×70 | 19 | 10.0 | 1.5 | 1×70 | 19 | 10.0 | 1.5 | 31.4 | 943 |
| 4×95 | 3×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 36.2 | 1290 |
| 4×120 | 3×120 | 19 | 13.0 | 1.7 | 1×120 | 19 | 13.0 | 1.7 | 39.6 | 1595 |
| 5×25 | 4×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 23.2 | 480 |
| 5×35 | 4×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 25.9 | 630 |
| 5×50 | 4×50 | 19 | 8.4 | 1.5 | 1×50 | 19 | 8.4 | 1.5 | 30.8 | 914 |
| 5×70 | 4×70 | 19 | 10.0 | 1.5 | 1×70 | 19 | 10.0 | 1.5 | 35.1 | 1179 |
| 5×95 | 4×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 40.5 | 1613 |
| 5×120 | 4×120 | 19 | 13.0 | 1.7 | 1×120 | 19 | 13.0 | 1.7 | 44.3 | 1993 |
ABC CABLE AS/NZS 3560.1
| No. of Core & Size |
Phase Core | Neutral Core | Complete Cable | |||||||
| No. & Section Area |
No. of Wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
No. & Section Area | No. of Wire | Dia. of Conductor (Approx.) |
Insulation Thickness |
Overall Dia. (Approx.) |
Weight (Approx.) |
|
| mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | mm | kg/km |
| 2×16 | 1×16 | 7 | 4.7 | 1.3 | 1×16 | 7 | 4.7 | 1.3 | 14.6 | 132 |
| 4×16 | 3×16 | 7 | 4.7 | 1.3 | 1×16 | 7 | 4.7 | 1.3 | 17.6 | 263 |
| 2×25 | 1×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 17.2 | 189 |
| 3×25 | 2×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 18.5 | 283 |
| 4×25 | 3×25 | 7 | 6.0 | 1.3 | 1×25 | 7 | 6.0 | 1.3 | 20.8 | 378 |
| 2×35 | 1×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 19.2 | 249 |
| 3×35 | 2×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 20.7 | 373 |
| 4×35 | 3×35 | 7 | 7.0 | 1.3 | 1×35 | 7 | 7.0 | 1.3 | 23.2 | 497 |
| 2×50 | 1×50 | 7 | 8.1 | 1.5 | 1×50 | 7 | 8.1 | 1.5 | 22.2 | 334 |
| 3×50 | 2×50 | 7 | 8.1 | 1.5 | 1×50 | 7 | 8.1 | 1.5 | 23.9 | 501 |
| 4×50 | 3×50 | 7 | 8.1 | 1.5 | 1×50 | 7 | 8.1 | 1.5 | 26.8 | 668 |
| 4×70 | 3×70 | 19 | 10.0 | 1.5 | 1×70 | 19 | 10.0 | 1.5 | 31.4 | 933 |
| 2×95 | 1×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 30.0 | 638 |
| 4×95 | 3×95 | 19 | 11.6 | 1.7 | 1×95 | 19 | 11.6 | 1.7 | 36.2 | 1276 |
| 4×120 | 3×120 | 19 | 13.0 | 1.7 | 1×120 | 19 | 13.0 | 1.7 | 39.6 | 1579 |
| 4×150 | 3×150 | 19 | 14.6 | 1.7 | 1×150 | 19 | 14.6 | 1.7 | 43.5 | 1883 |
ABC Cable GB 12527
| No. of Core & Size |
Phase Core | Neutral Core | Complete Cable | ||||||
| No. and Section Area |
No. of Wire | Dia.of Conductor (Approx.) |
Insulation Thickness |
No. and Section Area |
No. of Wire | Dia. of Conductor (Approx.) |
Overall Dia. (Approx.) |
Weight (Approx.) |
|
| mm2 | mm2 | No. | mm | mm | mm2 | No. | mm | mm | kg/km |
| 1×10 | 1×10 | 7 | 4.05 | 1.0 | – | – | – | 6.1 | 43 |
| 1×16 | 1×16 | 7 | 4.80 | 1.2 | – | – | – | 7.2 | 64 |
| 1×25 | 1×25 | 7 | 6.00 | 1.2 | – | – | – | 8.4 | 92 |
| 1×35 | 1×35 | 7 | 7.00 | 1.4 | – | – | – | 9.8 | 127 |
| 1×50 | 1×50 | 7 | 8.10 | 1.4 | – | – | – | 11.1 | 165 |
| 1×70 | 1×70 | 19 | 10.00 | 1.4 | – | – | – | 12.8 | 230 |
| 1×95 | 1×95 | 19 | 11.60 | 1.6 | – | – | – | 14.8 | 315 |
| 1×120 | 1×120 | 19 | 13.00 | 1.6 | – | – | – | 16.2 | 390 |
| 1×150 | 1×150 | 19 | 14.60 | 1.8 | – | – | – | 18.2 | 476 |
| 1×185 | 1×185 | 37 | 16.20 | 2.0 | – | – | – | 20.2 | 609 |
| 2×10 | 2×10 | 7 | 4.00 | 1.0 | – | – | – | 12.2 | 85 |
| 2×16 | 2×16 | 7 | 4.80 | 1.2 | – | – | – | 14.4 | 128 |
| 2×25 | 2×25 | 7 | 6.00 | 1.2 | – | – | – | 16.8 | 184 |
| 2×35 | 2×35 | 7 | 7.00 | 1.4 | – | – | – | 19.6 | 255 |
| 2×50 | 2×50 | 7 | 8.10 | 1.4 | – | – | – | 22.2 | 329 |
| 2×70 | 2×70 | 19 | 10.00 | 1.4 | – | – | – | 25.6 | 459 |
| 3×10 | 3×10 | 7 | 4.00 | 1.0 | – | – | – | 13.1 | 128 |
| 3×16 | 3×16 | 7 | 4.80 | 1.2 | – | – | – | 17.4 | 192 |
| 3×25 | 3×25 | 7 | 6.00 | 1.2 | – | – | – | 20.3 | 276 |
| 3×35 | 3×35 | 7 | 7.00 | 1.4 | – | – | – | 21.1 | 382 |
| 3×50 | 3×50 | 7 | 8.10 | 1.4 | – | – | – | 23.9 | 494 |
| 3×70 | 3×70 | 19 | 10.00 | 1.4 | – | – | – | 27.6 | 688 |
| 3×95 | 3×95 | 19 | 11.60 | 1.6 | – | – | – | 31.9 | 943 |
| 3×120 | 3×120 | 19 | 13.00 | 1.6 | – | – | – | 34.9 | 1170 |
| 4×10 | 4×10 | 7 | 4.00 | 1.0 | – | – | – | 14.6 | 171 |
| 4×16 | 4×16 | 7 | 4.80 | 1.2 | – | – | – | 17.4 | 256 |
| 4×25 | 4×25 | 7 | 6.00 | 1.2 | – | – | – | 20.3 | 368 |
| 4×35 | 4×35 | 7 | 7.00 | 1.4 | – | – | – | 23.7 | 509 |
| 4×50 | 4×50 | 7 | 8.10 | 1.4 | – | – | – | 26.8 | 659 |
| 4×70 | 4×70 | 19 | 10.00 | 1.4 | – | – | – | 30.9 | 917 |
| 4×95 | 4×95 | 19 | 11.60 | 1.6 | – | – | – | 35.8 | 1258 |
| 4×120 | 4×120 | 19 | 13.00 | 1.6 | – | – | – | 39.1 | 1559 |
| 1×16+16 | 1×16 | 7 | 4.80 | 1.2 | 1×16 | 7 | 5.10 | 12.3 | 108 |
| 1×25+25 | 1×25 | 7 | 6.00 | 1.2 | 1×25 | 7 | 6.30 | 14.7 | 158 |
| 1×35+35 | 1×35 | 7 | 7.00 | 1.4 | 1×35 | 7 | 7.50 | 17.3 | 221 |
| 1×50+50 | 1×50 | 7 | 8.40 | 1.4 | 1×50 | 7 | 9.00 | 20.1 | 300 |
| 2×16+16 | 2×16 | 7 | 4.80 | 1.2 | 1×16 | 7 | 5.10 | 15.5 | 172 |
| 2×25+25 | 2×25 | 7 | 6.00 | 1.2 | 1×25 | 7 | 6.30 | 18.1 | 250 |
| 2×35+35 | 2×35 | 7 | 7.00 | 1.4 | 1×35 | 7 | 7.50 | 21.1 | 348 |
| 2×50+50 | 2×50 | 7 | 8.30 | 1.4 | 1×50 | 7 | 9.00 | 22.4 | 464 |
| 3×16+16 | 3×16 | 7 | 4.80 | 1.2 | 1×16 | 7 | 5.10 | 17.4 | 235 |
| 3×25+25 | 3×25 | 7 | 6.00 | 1.2 | 1×25 | 7 | 6.30 | 20.3 | 342 |
| 3×35+35 | 3×35 | 7 | 7.00 | 1.4 | 1×35 | 7 | 7.50 | 23.7 | 475 |
| 3×50+50 | 3×50 | 7 | 8.10 | 1.4 | 1×50 | 7 | 9.00 | 26.8 | 629 |
| 3×70+70 | 3×70 | 19 | 10.00 | 1.4 | 1×70 | 19 | 10.50 | 30.9 | 869 |
| 3×95+95 | 3×95 | 19 | 11.60 | 1.6 | 1×95 | 19 | 12.50 | 35.7 | 1200 |
| 3×35+16 | 3×35 | 7 | 7.00 | 1.4 | 1×16 | 7 | 4.80 | 22.2 | 445 |
| 3×50+25 | 3×50 | 7 | 8.10 | 1.4 | 1×25 | 7 | 6.00 | 24.8 | 585 |
| 3×70+35 | 3×70 | 19 | 10.00 | 1.4 | 1×35 | 7 | 7.00 | 30.9 | 815 |
| 3×95+50 | 3×95 | 19 | 11.60 | 1.6 | 1×50 | 7 | 8.10 | 35.7 | 1108 |
| 4×95+35 | 4×95 | 19 | 11.60 | 1.6 | 1×35 | 7 | 7.00 | 39.9 | 1385 |
| 3×120+70 | 3×120 | 19 | 13.00 | 1.6 | 1×70 | 19 | 10.00 | 39.1 | 1399 |
| LV Aerial Bundled Conductor (ABC) Cables | overall diameter | weight | Maxinum conductor Resistance | Minimum breaking Load | current Rating |
| No.xmm2 | mm | kg/km | Ω/Km | KN | A |
| 1×16+1×25 RM | 15.3 | 160 | 1,910 | 2,5 | 72 |
| 3×16+1×25 RM | 19 | 290 | 1,200 | 4,0 | 107 |
| 3×25+1×25 RM | 23.2 | 400 | 0,868 | 5,5 | 132 |
| 3×35+1×25 RM | 25.6 | 500 | 0,641 | 8,0 | 165 |
| 3×50+1×35 RM | 30 | 680 | 0,443 | 10,7 | 205 |
| 3×70+1×50 RM | 34.9 | 920 | 0,320 | 13,7 | 240 |
| 3×95+1×70 RM | 40.6 | 1270 | 0,253 | 18,6 | 290 |
| 3×120+1×70 RM | 44.1 | 1510 | 0,206 | 23,2 | 334 |
| 3×150+1×95 RM | 49.2 | 1870 | 0,164 | 28,7 | 389 |
| 3×185+1×120 RM | 54.9 | 2340 | 0,125 | 37,2 | 467 |
| 3×25+1×25+1×16 RM | 23.2 | 470 | 1,910 | 2,5 | 72 |
| 3×35+1×25+1×16 RM | 25.6 | 560 | 1,200 | 4,0 | 107 |
| 3×50+1×35+1×16 RM | 30 | 740 | 0,868 | 5,5 | 132 |
| 3×70+1×50+1×16 RM | 34.9 | 980 | 0,641 | 8,0 | 165 |
| 3×95+1×70+1×16 RM | 40.6 | 1330 | 0,443 | 10,7 | 205 |
| 3×120+1×70+1×16 RM | 44.1 | 1580 | 0,320 | 13,7 | 240 |
| 3×150+1×95+1×16 RM | 49.2 | 1940 | 0,206 | 23,2 | 334 |
| 3×185+1×120+1×16 RM | 54.9 | 2410 | 1,910 | 2,5 | 72 |
HENAN UME CABLE CO., LTD has a strict quality control policy in every step from the order to After-sales service!
Production:
- Raw material inspection and test
- Production process test
- Unqualified product control
- Regular test and examination
- Finished product inspection
UME Cable was founded in 1994, located in Zhengzhou Gongyi Huiguo Town, and occupies a total area of more than 200,000 square meters, with a building area of 20,000 square meters. The real capital assets are more than USD 6 million, with a total of 230 staff members, 35 of which are professional and technical experts. The land of our factory and employees numbers might not be the top scale of industry, but our highly automatic facilities and elite employees are the best in the industry will guarantee you a high yield rate achieved by strict cost and quality control, this is why we could quote better quality with the most competitive price within the market.
Q1: Are you a manufacturer?
Yes, we are the manufacturer.
Q2: What are your main products?
Our products range as follows:
1. Electrical wire/PVC Building Wires.
2. PVC/XLPE insulated Power Cables up to 110kv.
3. Overhead Aerial Bundle Cable/ABC Cables.
4. Bare Conductors, like AAC, AAAC, ACSR, ACAR, ASCR/AW, and so on.
5. Steel wire/strand-like EHS, GSW and ACS(Aluminum Clad Steel), CCS(Copper Clad Steel).
6. Rubber Cables, Mining Cables, Welding Cable, and Control Cables.
7. Concentric Cables with Copper/Aluminum/Aluminum Alloy 8000s’ Conductor.
Q3: Do you provide samples? Is it free or extra?
Yes, we could offer the samples for free
Q4: Is the quality of your products guaranteed?
We have passed ISO9001, ISO14001, ISO45001, and all our products have CE certificates.
Q5: Which markets do you involve mainly in?
Our products have been exported mainly to Africa, the Middle East, Southeast Asia, South America, Central America, North America, Europe, Australia, etc.
Q6: What is your payment term?
T/T or L/C
Q7: What about the delivery time?
Generally, it is 3-7days if the goods are in stock. Or it is 7-30days if the goods are not in stock, it is according to quantity.
We are China Overhead Transmission Line Aerial Bundle Cables ABC Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular ABC Cable Products
Hot Sale Aluminum Conductor ABC Cable and Wire
XLPE Insulated Overhead Triplex Service Drop with Bare AAC ABC Cable Patella 2*6+6AWG
0.6/1kv 4*25mm Aluminum Conductor XLPE Insulation ABC Cable
LV Aerial Bundle Cable (600/1000V) 1X16 AAC/XLPE+16mm2 AAAC
Electrical Copper Wire 4 Core Aerial Overhead ABC Cable
Quadruplex Service Drop ACSR Neutral Conductor Gelding
Popular Aerial Bundled Cable (ABC Cable) Products
ABC Cable Electric Wire Overhead Insulated 15/25/35kv Medium Voltage Aerial Bundled Cable
High Quality XLPE, PE and PVC Insulated ABC Cable Aerial Bundled Cable
Stranded Aluminum Conductor Aerial Bundled Cables ABC Cable
11kv Aerial Bundle Bare ACSR Conductor Duplex ABC Cable
Aerial Bundled Cable Duplex/Triplex/Quadruplx Service Drop Cable
Popular Overhead Transmission Line Aerial Bundle Cables ABC Cable Products
Popular umecable Products
Irrigation Control Cable PVC Insulation Flexible Copper Conductor Control Cable
DIN 48206 IEC 61089 Aluminium Alloy Conductor Steel Reinforced – Aacsr 240/40 230/30 210/50mm2
0.6/1kv Cu/Al Conductor PVC Insulated Low Voltage Power Cables
Used for Secondary of Welding Machine Welders Yh Yhf 50mm2 70mm2 Electrical Rubber Welding Cable
Bare Solid Round Wire Overhead Transmission Line Bare Copper Conductor
Tags: ABC Cable, Aerial Bundled Cable (ABC Cable), Overhead Transmission Line Aerial Bundle Cables ABC Cable, umecable