Experienced Factory for Thw Wire with Copper Conductor
Experienced Factory for Thw Wire with Copper Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
APPLICATION:
THW wire with copper conductor is generally for wiring of lighting and power – residential,
Commercial, industrial buildings in accordance with the National Electrical
Code, maximum conductor temperature of 75° C in wet or dry locations,
For circuits not exceeding 600 volts
STANDARDS:
1. Listed by UL as Type THW per Standard 83.
2. All sizes carry the VW-1 flame test designation.
3. Listed by UL as Oil Resistant I.
4. Listed by UL as Sunlight Resistant (250 kcmil and larger, black only)
5.250 kcmil and larger pass UL and IEEE-383 ribbon burner flame test
And are listed For CT Use.
6. Conforms to Federal Specification J-C-30B.
CONSTRUCTION:
Annealed uncoated copper conductor, PVC insulation, surface printed.
SPECIFICATION:
1. SCOPE
1.1 This specification describes single conductor THW wire with copper conductor, a general purpose building wire insulated with polyvinyl chloride (PVC) intended for lighting and power circuits at 600 volts or less, in residential, commercial and industrial buildings. The wire may be operated at 75° C maximum continuous conductor temperature in wet or dry locations and is listed by Underwriters Laboratories for use in accordance with Article 310 of the National Electrical Code.
2. APPLICABLE SPECIFICATIONS
2.1 The following specifications form a part of this specification to the extent specified herein:
2.1.1 Underwriters Laboratories Standard 83 for Thermoplastic Insulated Wires.
2.1. 2 Federal Specification J-C-30B.
3. CONDUCTORS
3.1 Conductors of THW wire shall be solid or Class B stranded, annealed uncoated copper per UL Standard 83.
4. INSULATION
4.1 Each conductor shall be insulated with PVC complying with the physical and electrical requirements of UL Standard 83 for Type THW. In addition, the PVC insulation shall comply with the optional Oil Resistant I listing of UL Standard 83.
4.2 The average thickness of insulation, for a given conductor size, shall be as specified in UL Standard 83 for Type THW wire. The minimum thickness at any point shall be not less than 90% of the specified average thickness.
The insulation shall be applied tightly to the conductor and shall be free-stripping.
5. IDENTIFICATION
5.1 The wire shall be identified by surface marking indicating manufacturer’s identification, conductor size and metal, voltage rating, UL Symbol, type designation and optional ratings.
6. TESTS
6.1 Wire shall be tested in accordance with the requirements of UL Standard 83 for Type THW wire and for the optional Oil Resistant listing.
7. LABELS
7.1 THW wire with copper conductor shall bear the Underwriters Laboratories label for Type THW.
NOTE:
If you want to know more details about this THW wire with copper conductor, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Ampacity in accordance with NEC for not more than these conductors in raceway, 750C conductor temperature and 300C ambient in wet or dry locations.
| Size AWG or kcmil |
No. of strands | Insulation thickness mils |
Nominal Diameter inch |
NEC Ampacity |
Approx. weight (lbs/1000ft) | |
| copper | Net | |||||
| 14 | Solid | 30 | 0.13 | 20 | 12 | 19 |
| 12 | Solid | 30 | 0.15 | 25 | 20 | 26 |
| 10 | Solid | 30 | 0.17 | 35 | 31 | 39 |
| 14 | 7 | 30 | 0.14 | 20 | 13 | 19 |
| 12 | 7 | 30 | 0.16 | 25 | 20 | 28 |
| 10 | 7 | 30 | 0.18 | 35 | 32 | 41 |
| 8 | 7 | 45 | 0.24 | 50 | 50 | 67 |
| 6 | 7 | 60 | 0.30 | 65 | 81 | 105 |
| 4 | 7 | 60 | 0.35 | 85 | 129 | 160 |
| 3 | 7 | 60 | 0.38 | 100 | 163 | 195 |
| 2 | 7 | 60 | 0.41 | 115 | 205 | 245 |
| 1 | 19 | 80 | 0.49 | 130 | 258 | 315 |
| 1/0 | 19 | 80 | 0.53 | 150 | 326 | 390 |
| 2/0 | 19 | 80 | 0.57 | 175 | 411 | 480 |
| 3/0 | 19 | 80 | 0.62 | 200 | 518 | 595 |
| 4/0 | 19 | 80 | 0.68 | 230 | 653 | 735 |
| 250 | 37 | 95 | 0.75 | 255 | 772 | 880 |
| 300 | 37 | 95 | 0.81 | 285 | 926 | 1040 |
| 350 | 37 | 95 | 0.86 | 310 | 1081 | 1205 |
| 400 | 37 | 95 | 0.90 | 335 | 1235 | 1365 |
| 500 | 37 | 95 | 0.98 | 380 | 1544 | 1685 |
| 600 | 61 | 110 | 1.09 | 420 | 1853 | 2030 |
| 750 | 61 | 110 | 1.18 | 475 | 2316 | 2510 |
| 1000 | 61 | 110 | 1.34 | 545 | 3088 | 3305 |
We are China Experienced Factory for Thw Wire with Copper Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Building Wire Products
ISO9001 Approved Copper Hebei Huatong Cables Soft Packing, or as Your Request Wire Nmd90 300V
Nylon Jacket Electrical Cable Building Wire Thhn
Thhn Wire Cable Electrical Copper Thw UL83 Standard
300/500V ISO Standard PVC Insulated Copper Electric Wire
UL Listed Mhf 2/0-2/0-1-4 Aluminum Mobile Home Feeder Cable
Electrical Cable Copper Electrical Wire Gauge 14/2 Nmd90 Cable
Popular Electric Wire Products
Copper Red Green Yellow Black Blue PVC House Wiring Electric Twist Flat Wire Cable
Energy Wire/Copper/PVC Insulated Electric Wires 450/750V
6181Y 1X25mm2 PVC Insulated and Sheathed Wiring Cable BS 6004 300/500V
All Aluminium Conductor Steel Reinforced Alloys Aluminium Conductor
Huatong Insulated Ht Cables Coils and Drums 14AWG-1000mcm Cable Rpv
Popular jytopcable Products
Flexibile Electric Wire PVC Insulated Electric Wire 2.5sq. mm
PVC Jacket Flexible Battery Cable, Electrical Wire Cable
Overhead Aluminum Conductor XLPE Insualted Aerial Bundled ABC Cable
450/750V Nya Cable H07V-U H07V-R with Ce Certificate
NF-C33-209 French Standard 3X70+54.6+2X16 mm2 ABC Bundled Cable
Overhead Transmission Lines ABC Aerial Bundled Cable
Popular Thw Wire Products
PVC Copper Wire for Household Use
Experience Factory for PVC Insulated Thw Wire
95 Degree Nylon Thhn Thwn Wire #14, #12, #8 #6, # 1/0 Electric Copper Wire
Building Electrical Cable Wire 3mm Price
UL Styles 1007 Hook up Wire 12AWG 600V
Tags: Building Wire, Electric Wire, jytopcable, Thw Wire