600V Thhn Wire with Nylon Jacket
600V Thhn Wire with Nylon Jacket image
Get Latest Price Request a quote
Quick Details
Product Details
APPLICATION Suitable for use as follows:
THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2;
When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90° C;
When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90° C or not to exceed 75° C when exposed to oil or coolant;
When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60° C or dry locations at temperatures not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)
Conductor temperatures not to exceed 105° C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts
STANDARDS & REFERENCE
THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.
CONSTRUCTION
THHN or THWN-2* or MTW copper conductors are annealed (soft) copper, insulated with a tough heat and moisture resistant polyvinyl chloride (PVC), over which a nylon (polyamide) or UL-listed equal jacket is applied Available in black, white, red, blue, green, yellow, brown, orange, and gray; Some colors standard, some subject to economic order quantity
Conductor sizes 2 AWG and larger listed and marked sunlight-resistant in black only
SPECIFICATION
MTW or THHN or THWN-2
Conductors shall be UL-listed Type MTW or THHN or THWN-2* gasoline and oil resistant II, suitable for operations at 600 volts as specified in the National Electrical Code. Sizes 14 through 1 AWG shall be rated VW-1, larger sizes shall be listed for CT use. Sizes 2 AWG and larger listed and marked sunlight-resistant in black only. Conductors shall be annealed copper, insulated with high-heat and moisture resistant PVC, jacketed with abrasion, moisture, gasoline, and oil resistant nylon or listed equivalent
AWM
Conductors shall be UL-listed Type THHN or THWN-2* or MTW or AWM, suitable for
Operation at 600 volts at conductor temperatures not to exceed 105° C.
We are China 600V Thhn Wire with Nylon Jacket manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular jytopcable Products
450/750V PVC Insulated Aluminum Cable
0.6/1kv N2xy Electrical Cable Low Voltage LV N2xy Electric Cable
Mv 11kv XLPE Insulated Armored Power Cable 3X95sq. mm
Middle Voltage 11kv Copper Conductor XLPE Insulated Electric Cable
Low Voltage Armoured Cable PVC Cable with CE Certificate
Popular Thhn AWG 10 Products
Popular Thhn Cable Products
8AWG Copper Conductor PVC Insulated Nylon Jacket Thhn Wire 600V
500mcm Copper Conductor PVC Insulated Nylon Jacket Thhn Wire 600V
Nylon Jacket Standard Single Core 4/0 AWG Building Wire Flexible Cable
600V UL83 Building Wire Thhn Thwn Thwn-2 Copper Electrical Cable
Copper Single Core Thhn/Thwn Electric Cable Wire
600V Copper Wire PVC Insulated Thhn Building Cable
Popular Thhn Wire Products
Thhn 500mcm Thhn 500kcmil Thwn-2 Cable
Thw Thw-2 Tw Thhn Thwn 4/0 Cable Power Electric UL Cable
UL Listed Electrical Wire 600V Thhn Wire Copper Conductor PVC Insulated Nylon Jacket Thhn Cable
UL Listed Monoconductor 600V Thhn 12AWG Copper Cable
Thhn Wire 12AWG Thhn 10 AWG Thhn 8AWG Thhn UL Wire Building Cable
Tags: jytopcable, Thhn AWG 10, Thhn Cable, Thhn Wire