0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable
0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Rated Voltage: 0.6/1kv Conductor material: copper
Insulation material: PVC Sheath Material: PVC
Core: 1,2,3, 4,5, 3+1,3+2,4+1 Certificate: ISO, CCC,BV
Standard: GB/T12706-2002
Trademark: jytop or OEM
Installation temperature: not lower than 0°C
Operating Temperature: 70°C Max
Short-circuit Max. Conductor Temperature: 160°C
Short-circuit Max : 5s
Bending radius: not be less than 15 times of cable outer diameter
Application: Being laid indoors, in tunnels or in ducts, unable to bear mechanical external force.
Technical data of 0.6/1KV, Single core, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 1x10mm2 | RM | 1.0 | 0.2 | 1.8 | 12.9 | 3.08 |
| 1x16mm2 | RM | 1.0 | 0.2 | 1.8 | 13.9 | 1.91 |
| 1x25mm2 | RM | 1.2 | 0.2 | 1.8 | 14.3 | 1.20 |
| 1x35mm2 | RM | 1.2 | 0.2 | 1.8 | 15.5 | 0.868 |
| 1x50mm2 | RM | 1.4 | 0.2 | 1.8 | 17.2 | 0.641 |
| 1x70mm2 | RM | 1.4 | 0.2 | 1.8 | 19.0 | 0.443 |
| 1x95mm2 | RM | 1.6 | 0.2 | 1.8 | 21.3 | 0.320 |
| 1x120mm2 | RM | 1.6 | 0.2 | 1.8 | 22.9 | 0.253 |
| 1x150mm2 | RM | 1.8 | 0.2 | 1.8 | 24.9 | 0.206 |
| 1x185mm2 | RM | 2.0 | 0.2 | 1.8 | 27.1 | 0.164 |
| 1x240mm2 | RM | 2.2 | 0.2 | 1.8 | 30.2 | 0.125 |
| 1x300mm2 | RM | 2.4 | 0.5 | 2.0 | 35.2 | 0.100 |
| 1x400mm2 | RM | 2.6 | 0.5 | 2.1 | 38.8 | 0.0778 |
| 1x500mm2 | RM | 2.8 | 0.5 | 2.2 | 43.0 | 0.0605 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, two cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 2×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 12.9 | 18.1 |
| 2×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.7 | 12.1 |
| 2x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 15.5 | 7.41 |
| 2x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.5 | 4.61 |
| 2x10mm2 | RM | 1.0 | 0.2 | 1.8 | 19.1 | 3.08 |
| 2x16mm2 | RM | 1.0 | 0.2 | 1.8 | 21.2 | 1.91 |
| 2x25mm2 | SM | 1.2 | 0.2 | 1.8 | 18.6 | 1.20 |
| 2x35mm2 | SM | 1.2 | 0.2 | 1.8 | 20.1 | 0.868 |
| 2x50mm2 | SM | 1.4 | 0.2 | 1.8 | 22.4 | 0.641 |
| 2x70mm2 | SM | 1.4 | 0.5 | 2.0 | 26.9 | 0.443 |
| 2x95mm2 | SM | 1.6 | 0.5 | 2.1 | 30.3 | 0.320 |
| 2x120mm2 | SM | 1.6 | 0.5 | 2.2 | 32.6 | 0.253 |
| 2x150mm2 | SM | 1.8 | 0.5 | 2.3 | 35.5 | 0.206 |
| 2x185mm2 | SM | 2.0 | 0.5 | 2.5 | 39.1 | 0.164 |
| 2x240mm2 | SM | 2.2 | 0.5 | 2.7 | 43.6 | 0.125 |
| 2x300mm2 | SM | 2.4 | 0.5 | 2.8 | 47.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, three cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 3×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 13.4 | 18.1 |
| 3×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.3 | 12.1 |
| 3x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 16.1 | 7.41 |
| 3x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 4.61 |
| 3x10mm2 | RM | 1.0 | 0.2 | 1.8 | 20.0 | 3.08 |
| 3x16mm2 | RM | 1.0 | 0.2 | 1.8 | 22.3 | 1.91 |
| 3x25mm2 | SM | 1.2 | 0.2 | 1.8 | 21.3 | 1.20 |
| 3x35mm2 | SM | 1.2 | 0.2 | 1.8 | 23.2 | 0.868 |
| 3x50mm2 | SM | 1.4 | 0.2 | 1.9 | 26.2 | 0.641 |
| 3x70mm2 | SM | 1.4 | 0.5 | 2.0 | 31.1 | 0.443 |
| 3x95mm2 | SM | 1.6 | 0.5 | 2.2 | 35.4 | 0.320 |
| 3x120mm2 | SM | 1.6 | 0.5 | 2.3 | 38.2 | 0.253 |
| 3x150mm2 | SM | 1.8 | 0.5 | 2.4 | 41.7 | 0.206 |
| 3x185mm2 | SM | 2.0 | 0.5 | 2.6 | 46.0 | 0.164 |
| 3x240mm2 | SM | 2.2 | 0.5 | 2.8 | 51.4 | 0.125 |
| 3x300mm2 | SM | 2.4 | 0.5 | 3.0 | 56.5 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 3+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 3×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 14.9 | 12.1 | 18.1 |
| 3×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 16.7 | 7.41 | 12.1 |
| 3×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 18.2 | 4.61 | 7.41 |
| 3×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 20.8 | 3.08 | 4.61 |
| 3×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 23.5 | 1.91 | 3.08 |
| 3×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 24.2 | 1.20 | 1.91 |
| 3×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 25.9 | 0.868 | 1.91 |
| 3×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.0 | 30.5 | 0.641 | 1.20 |
| 3×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.9 | 0.443 | 0.868 |
| 3×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.3 | 38.5 | 0.320 | 0.641 |
| 3×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 41.8 | 0.253 | 0.443 |
| 3×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.5 | 45.0 | 0.206 | 0.443 |
| 3×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.7 | 49.9 | 0.164 | 0.320 |
| 3×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 2.9 | 55.5 | 0.125 | 0.253 |
| 3×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.1 | 61.0 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, four cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables
CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) | Nominal thickness of steel tape(mm) | Nominal thickness of PVC sheath(mm) | Approx. cable overall diameter (mm) | Max. D.C resistance @ 200C (Ω/km) |
| 4×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 14.2 | 18.1 |
| 4×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.1 | 12.1 |
| 4x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 17.2 | 7.41 |
| 4x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 4.61 |
| 4x10mm2 | RM | 1.0 | 0.2 | 1.8 | 21.6 | 3.08 |
| 4x16mm2 | RM | 1.0 | 0.2 | 1.8 | 24.1 | 1.91 |
| 4x25mm2 | SM | 1.2 | 0.2 | 1.8 | 23.8 | 1.20 |
| 4x35mm2 | SM | 1.2 | 0.2 | 1.8 | 25.9 | 0.868 |
| 4x50mm2 | SM | 1.4 | 0.5 | 2.0 | 31.4 | 0.641 |
| 4x70mm2 | SM | 1.4 | 0.5 | 2.1 | 35.0 | 0.443 |
| 4x95mm2 | SM | 1.6 | 0.5 | 2.3 | 39.9 | 0.320 |
| 4x120mm2 | SM | 1.6 | 0.5 | 2.4 | 43.1 | 0.253 |
| 4x150mm2 | SM | 1.8 | 0.5 | 2.6 | 47.3 | 0.206 |
| 4x185mm2 | SM | 2.0 | 0.5 | 2.8 | 52.3 | 0.164 |
| 4x240mm2 | SM | 2.2 | 0.5 | 3.0 | 58.4 | 0.125 |
| 4x300mm2 | SM | 2.4 | 0.5 | 3.2 | 64.3 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, five cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables , CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation (mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath(mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
| 5×1.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 15.0 | 18.1 |
| 5×2.5mm2 | RE or RM | 0.8 | 0.2 | 1.8 | 16.1 | 12.1 |
| 5x4mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 18.5 | 7.41 |
| 5x6mm2 | RE or RM | 1.0 | 0.2 | 1.8 | 19.8 | 4.61 |
| 5x10mm2 | RM | 1.0 | 0.2 | 1.8 | 23.3 | 3.08 |
| 5x16mm2 | RM | 1.0 | 0.2 | 1.8 | 26.2 | 1.91 |
| 5x25mm2 | SM | 1.2 | 0.2 | 1.8 | 26.1 | 1.20 |
| 5x35mm2 | SM | 1.2 | 0.5 | 2.0 | 30.7 | 0.868 |
| 5x50mm2 | SM | 1.4 | 0.5 | 2.1 | 34.6 | 0.641 |
| 5x70mm2 | SM | 1.4 | 0.5 | 2.3 | 38.9 | 0.443 |
| 5x95mm2 | SM | 1.6 | 0.5 | 2.5 | 44.4 | 0.320 |
| 5x120mm2 | SM | 1.6 | 0.5 | 2.6 | 47.9 | 0.253 |
| 5x150mm2 | SM | 1.8 | 0.5 | 2.8 | 52.6 | 0.206 |
| 5x185mm2 | SM | 2.0 | 0.5 | 2.9 | 57.9 | 0.164 |
| 5x240mm2 | SM | 2.2 | 0.5 | 3.2 | 65.0 | 0.125 |
| 5x300mm2 | SM | 2.4 | 0.5 | 3.4 | 71.6 | 0.100 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
Technical data of 0.6/1KV, 4+1 cores, Copper or Aluminum conductor, PVC insulated, double steel tape armored and PVC or PE sheath cables, CABLE CONSTRUCTION 0.6/1KV AL/PVC/DSTA/PVC or PE
| Cable size |
Conductor type |
Nominal thickness of PVC insulation(mm) |
Nominal thickness of steel tape(mm) |
Nominal thickness of PVC sheath (mm) |
Approx. cable overall diameter (mm) |
Max. D.C resistance @ 200C (Ω/km) |
|||
| Phase core |
Earth core |
Phase core |
Earth core |
Phase core |
Earth core |
||||
| 4×2.5+1.5mm2 | RE | RE | 0.8 | 0.8 | 0.2 | 1.8 | 15.9 | 12.1 | 18.1 |
| 4×4+2.5mm2 | RE | RE | 1.0 | 0.8 | 0.2 | 1.8 | 18.0 | 7.41 | 12.1 |
| 4×6+4mm2 | RE | RE | 1.0 | 1.0 | 0.2 | 1.8 | 19.6 | 4.61 | 7.41 |
| 4×10+6mm2 | RM | RE | 1.0 | 1.0 | 0.2 | 1.8 | 22.6 | 3.08 | 4.61 |
| 4×16+10mm2 | RM | RM | 1.0 | 1.0 | 0.2 | 1.8 | 25.6 | 1.91 | 3.08 |
| 4×25+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.8 | 26.6 | 1.20 | 1.91 |
| 4×35+16mm2 | SM | RM | 1.2 | 1.0 | 0.2 | 1.9 | 28.7 | 0.868 | 1.91 |
| 4×50+25mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.1 | 33.8 | 0.641 | 1.20 |
| 4×70+35mm2 | SM | SM | 1.4 | 1.2 | 0.5 | 2.3 | 37.8 | 0.443 | 0.868 |
| 4×95+50mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.4 | 42.8 | 0.320 | 0.641 |
| 4×120+70mm2 | SM | SM | 1.6 | 1.4 | 0.5 | 2.6 | 46.6 | 0.253 | 0.443 |
| 4×150+70mm2 | SM | SM | 1.8 | 1.4 | 0.5 | 2.7 | 50.4 | 0.206 | 0.443 |
| 4×185+95mm2 | SM | SM | 2.0 | 1.6 | 0.5 | 2.9 | 55.9 | 0.164 | 0.320 |
| 4×240+120mm2 | SM | SM | 2.2 | 1.6 | 0.5 | 3.1 | 62.2 | 0.125 | 0.253 |
| 4×300+150mm2 | SM | SM | 2.4 | 1.8 | 0.5 | 3.3 | 68.4 | 0.100 | 0.206 |
Note: RE= round conductor RM = stranded conductor SM=sectional conductor
We are China 0.6/1kv Copper Conductor PVC Insulated PVC Jacket Electric Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Electrical Cable Products
ACSR Conductor AAC AAAC Conductor for Overhead Line
3 Core 4 Core 5 Core 240mm XLPE Insulated Armoured 95mm2 Power Cable
0.6 / 1 Kv Cu XLPE PVC Low Voltage Power Cable at Good Price
Hot New Products PVC Rubber Insulated Welding Cable Covered Flexible Pure Copper Conductor
Popular jytopcable Products
LV and Mv Electric Cable with Three Cores, 3core Cable
Low Voltage LV 3+2 Core Copper XLPE Insulated Aluminium Steel Wire Armored Cable
Copper Conductor XLPE Insulated Power Cable for 12/20kv
Yavv Nayy Aluminum Cable PVC Insulated Cables with Aluminium Conductor
Copper Clad Wire CCA Wire Stranded
Secondary Urd Single XLPE Insulation Aluminum Conductor Underground Cable
Popular PVC Insulated Cable Products
H07V-K Copper Single Core Cable PVC for Installation 2.5mm2 Red
Nayy Aluminum Conductor PVC Sheathed Electrical Power Cable
Low Voltage XLPE Insulation Cable
1000V Aluminum XLPE Insulation Swa Power Cable
Multicores Copper Flexible Control/ Signal Cable 2.5mm
450/750V PVC Used as Electrical Power
Popular PVC Jacket Cable Products
BVVB Type Flat Twin PVC Cabling Insulation PVC Jacket Cable
PVC Jacket Flexible Battery Cable, Electrical Wire Cable
Five Cores PVC Copper Cable, PVC Jacket Cable Premium Quality 2 Years Warranty
H05V-U, H05V-K, H05V-R Single Core Copper Flexible PVC Insulated Jacket Wire and Cable
Tags: Electrical Cable, jytopcable, PVC Insulated Cable, PVC Jacket Cable