AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable
AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Product Description
AAAC All Aluminum Alloy Conductor Aerial Bundle Cable
1. Specification
| JL All Aluminum Conductor Basic parameter | ||
| Specification | Outer Diameter of Cable | Approximate weight |
| 10 | 4.05 | 27.95 |
| 16 | 5.13 | 45.00 |
| 25 | 6.39 | 69.59 |
| 35 | 7.50 | 96.14 |
| 40 | 8.10 | 112.08 |
| 50 | 9.00 | 138.35 |
| 63 | 10.20 | 176.64 |
| 70 | 10.80 | 199.28 |
| 95 | 12.50 | 265.80 |
| 100 | 13.0 | 279.49 |
| 120 | 14.3 | 338.18 |
| 125 | 14.5 | 349.36 |
| 150 | 15.8 | 413.65 |
| 160 | 16.4 | 447.18 |
| 185 | 17.5 | 511.47 |
| 200 | 18.3 | 558.98 |
| 210 | 18.8 | 586.93 |
| 240 | 20.0 | 667.98 |
| 250 | 20.5 | 698.73 |
| 300 | 22.4 | 832.88 |
| 315 | 23.0 | 880.39 |
| 400 | 26.0 | 1117.96 |
| 450 | 27.6 | 1260.50 |
| 500 | 29.1 | 1405.84 |
| 560 | 30.7 | 1565.15 |
| 630 | 32.7 | 1763.58 |
| 710 | 34.7 | 1984.38 |
| 800 | 36.8 | 2238.72 |
| JL/G1A JL/G2A JL/G3A JL1/G1A JL1/G2A JL1/G3A JL2/G1A JL2/G2A JL2/G3A &JL3/G1A JL3/G2A JL3/G3A Aluminum Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.68 | 240/30 | 21.6 | 932.18 |
| 16/3 | 5.55 | 66.23 | 240/40 | 21.7 | 975.04 |
| 25/4 | 6.90 | 102.35 | 240/55 | 22.4 | 1117.98 |
| 35/6 | 8.16 | 143.40 | 250/25 | 21.5 | 892.12 |
| 40/6 | 8.73 | 164.01 | 250/40 | 22.2 | 1020.00 |
| 50/8 | 9.60 | 198.46 | 300/15 | 23.0 | 950.86 |
| 50/30 | 11.6 | 375.35 | 300/20 | 23.1 | 995.25 |
| 65/10 | 11.0 | 259.24 | 300/25 | 23.8 | 1069.16 |
| 70/10 | 11.4 | 279.25 | 300/40 | 23.9 | 1145.53 |
| 70/40 | 13.6 | 516.07 | 300/50 | 24.3 | 1223.68 |
| 95/15 | 13.6 | 384.61 | 300/70 | 25.2 | 1415.26 |
| 95/20 | 13.9 | 414.19 | 315/22 | 23.9 | 1055.27 |
| 95/55 | 16.0 | 714.12 | 400/20 | 26.9 | 1299.71 |
| 100/17 | 13.8 | 411.31 | 400/25 | 26.6 | 1309.52 |
| 120/7 | 14.5 | 384.69 | 400/35 | 26.8 | 1364.35 |
| 120/20 | 15.1 | 472.61 | 400/50 | 27.6 | 1526.85 |
| 120/25 | 15.7 | 532.00 | 400/65 | 28.0 | 1629.04 |
| 120/70 | 18.0 | 903.79 | 400/95 | 29.1 | 1876.79 |
| 125/7 | 14.9 | 404.07 | 450/30 | 28.6 | 1503.20 |
| 125/20 | 15.6 | 588.54 | 450/60 | 29.3 | 1721.49 |
| 150/8 | 16.0 | 468.73 | 500/35 | 30.1 | 1670.57 |
| 150/20 | 16.7 | 556.46 | 500/45 | 30.0 | 1706.92 |
| 150/25 | 17.1 | 607.47 | 500/65 | 30.9 | 1905.37 |
| 150/35 | 17.5 | 682.39 | 560/40 | 31.8 | 1869.84 |
| 160/9 | 16.8 | 517.20 | 560/70 | 32.7 | 2122.01 |
| 185/10 | 18.0 | 591.98 | 630/45 | 33.8 | 2100.58 |
| 185/25 | 18.9 | 713.67 | 630/55 | 34.3 | 2233.15 |
| 185/30 | 18.9 | 739.53 | 630/80 | 34.7 | 2386.32 |
| 185/45 | 19.6 | 857.27 | 710/50 | 35.9 | 2369.95 |
| 200/11 | 18.8 | 646.60 | 710/90 | 36.8 | 2688.85 |
| 210/10 | 19.0 | 659.36 | 720/50 | 36.2 | 2421.77 |
| 210/25 | 20.0 | 798.05 | 800/55 | 38.4 | 2719.46 |
| 210/35 | 20.4 | 864.06 | 800/70 | 38.6 | 2821.09 |
| 210/50 | 20.9 | 969.34 | 800/100 | 39.1 | 3038.27 |
| All Aluminum Alloy Conductor Basic parameter | |||||
| JLHA1 JLHA2 | JLHA3 JLHA4 | ||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 16 | 5.13 | 45.11 | 25 | 6.39 | 69.77 |
| 20 | 5.49 | 51.56 | 35 | 7.50 | 96.39 |
| 25 | 6.39 | 69.77 | 40 | 8.10 | 112.37 |
| 30 | 6.87 | 80.70 | 50 | 9.00 | 138.71 |
| 35 | 7.56 | 97.79 | 70 | 10.8 | 199.79 |
| 45 | 8.67 | 128.62 | 95 | 12.5 | 266.48 |
| 50 | 9.06 | 140.39 | 100 | 13.0 | 280.21 |
| 70 | 10.7 | 196.43 | 120 | 14.3 | 339.06 |
| 75 | 10.9 | 202.87 | 125 | 14.5 | 350.27 |
| 95 | 12.5 | 266.48 | 150 | 15.8 | 414.72 |
| 120 | 13.9 | 322.25 | 185 | 17.5 | 512.79 |
| 145 | 15.5 | 400.71 | 200 | 18.3 | 560.43 |
| 150 | 15.9 | 420.32 | 210 | 18.8 | 588.45 |
| 185 | 17.6 | 515.59 | 240 | 20.0 | 669.71 |
| 210 | 18.8 | 588.45 | 250 | 20.5 | 700.54 |
| 230 | 19.7 | 644.49 | 275 | 21.6 | 773.39 |
| 240 | 20.1 | 672.51 | 280 | 21.7 | 781.80 |
| 300 | 22.5 | 837.84 | 300 | 22.4 | 835.04 |
| 360 | 24.7 | 1014.37 | 315 | 23.0 | 882.67 |
| 400 | 26.0 | 1120.86 | 335 | 23.8 | 941.52 |
| 465 | 27.9 | 1288.98 | 340 | 23.9 | 952.73 |
| 500 | 29.1 | 1401.07 | 400 | 26.0 | 1120.86 |
| 520 | 29.5 | 1451.51 | 425 | 26.8 | 1193.71 |
| 580 | 31.2 | 1611.23 | 450 | 27.6 | 1263.77 |
| 630 | 32.7 | 1768.15 | 500 | 29.1 | 1409.48 |
| 650 | 33.0 | 1807.38 | 530 | 30.0 | 1487.94 |
| 720 | 35.0 | 2031.55 | 560 | 30.7 | 1569.20 |
| 800 | 36.8 | 2244.51 | 630 | 32.7 | 1768.15 |
| 675 | 33.8 | 1888.64 | |||
| 710 | 34.7 | 1989.52 | |||
| 800 | 36.8 | 2244.51 | |||
| JL(JL1,JL2,JL3)/LHA1 Aluminum Conductor Alloy Reinforced Basic parameter |
||
| Specification | Outer Diameter of Cable | Approximate weight |
| 25/20 | 8.34 | 118.92 |
| 40/30 | 10.5 | 187.47 |
| 60/45 | 13.2 | 297.71 |
| 80/50 | 14.9 | 368.16 |
| 105/60 | 16.8 | 470.27 |
| 130/140 | 21.4 | 758.42 |
| 135/80 | 18.9 | 593.36 |
| 135/140 | 21.6 | 772.42 |
| 135/145 | 21.7 | 780.81 |
| 165/170 | 23.8 | 940.34 |
| 165/175 | 23.9 | 951.53 |
| 170/95 | 21.1 | 739.68 |
| 210/220 | 26.8 | 1192.21 |
| 210/230 | 27.6 | 1262.18 |
| 235/250 | 28.7 | 1368.52 |
| 260/275 | 30.2 | 1516.85 |
| 265/60 | 23.4 | 906.83 |
| 270/420 | 34.2 | 1937.11 |
| 307/470 | 36.3 | 2177.85 |
| 335/80 | 26.4 | 1155.14 |
| 345/530 | 38.5 | 2454.98 |
| 365/165 | 30.0 | 1485.29 |
| 375/85 | 27.9 | 1293.28 |
| 415/95 | 29.5 | 1441.20 |
| 455/205 | 33.5 | 1854.52 |
| 465/110 | 31.2 | 1616.24 |
| 465/210 | 33.8 | 1885.28 |
| 505/65 | 31.1 | 1594.69 |
| 515/230 | 35.6 | 2092.27 |
| 535/240 | 36.2 | 2159.39 |
| 570/390 | 40.3 | 2677.54 |
| 580/260 | 37.7 | 2352.41 |
| 630/430 | 42.5 | 2979.70 |
| 650/295 | 40.0 | 2640.52 |
| 665/300 | 40.5 | 2710.44 |
| 705/485 | 45.0 | 3343.43 |
| 745/335 | 42.8 | 3029.31 |
| 790/540 | 47.5 | 3732.32 |
| 800/550 | 47.9 | 3785.48 |
| JLHA3/G1A (G2A ,G3A)&JLHA4/G1A (G2A ,G3A) Aluminum Alloy Conductor Steel Reinforced Basic parameter |
|||||
| Specification | Outer Diameter of Cable | Approximate weight | Specification | Outer Diameter of Cable | Approximate weight |
| 10/2 | 4.50 | 43.75 | 240/40 | 21.7 | 976.77 |
| 16/3 | 5.55 | 66.35 | 240/55 | 22.4 | 1119.73 |
| 35/6 | 8.16 | 143.66 | 300/15 | 23.0 | 953.01 |
| 50/8 | 9.60 | 198.81 | 300/20 | 23.4 | 1014.02 |
| 50/30 | 11.6 | 375.72 | 300/25 | 23.8 | 1071.37 |
| 70/10 | 11.4 | 279.74 | 300/40 | 23.9 | 1147.70 |
| 70/40 | 13.6 | 516.58 | 300/50 | 24.3 | 1225.85 |
| 95/15 | 13.6 | 385.29 | 300/70 | 25.2 | 1417.47 |
| 95/20 | 13.9 | 414.88 | 400/20 | 26.9 | 1302.65 |
| 95/55 | 16.0 | 714.82 | 400/25 | 26.6 | 1312.36 |
| 120/7 | 14.5 | 385.63 | 400/35 | 26.8 | 1367.18 |
| 120/20 | 15.1 | 473.45 | 400/50 | 27.6 | 1529.74 |
| 120/25 | 15.7 | 532.89 | 400/65 | 28.0 | 1631.93 |
| 120/70 | 18.0 | 904.67 | 400/95 | 29.1 | 1879.75 |
| 150/8 | 16.0 | 469.77 | 460/60 | 29.8 | 1778.19 |
| 150/20 | 16.7 | 557.51 | 500/35 | 30.1 | 1674.19 |
| 150/25 | 17.1 | 608.54 | 500/45 | 30.0 | 1710.46 |
| 150/35 | 17.5 | 683.45 | 500/65 | 31.0 | 1920.55 |
| 185/10 | 18.0 | 593.31 | 630/45 | 33.8 | 2105.13 |
| 185/25 | 18.9 | 715.03 | 630/55 | 34.3 | 2237.78 |
| 185/30 | 18.9 | 740.84 | 630/80 | 34.5 | 2365.74 |
| 185/45 | 19.6 | 858.61 | 710/50 | 35.9 | 2375.08 |
| 210/10 | 19.0 | 660.83 | 710/90 | 36.8 | 2693.98 |
| 210/25 | 20.0 | 799.56 | 720/50 | 36.2 | 2427.02 |
| 210/35 | 20.4 | 865.59 | 800/55 | 38.2 | 2688.92 |
| 210/50 | 20.9 | 970.85 | 800/70 | 38.6 | 2826.94 |
| 240/30 | 21.6 | 933.95 | 800/100 | 39.1 | 3041.69 |
2. Our Factory
3. Our Honor
4. Contact Details
Jessica Wang | Taifeng Cable Co., Ltd.
Add.: Heda Center, No.177 Tailiu Road, Shibei District, Qingdao, China
Factory Add.: No.1 Taifeng Road, Dacaozhuang Administrative Zone, Xingtai City, Hebei Province, China
Tel: 0086 532 85611663
Phone: 0086 15192706553
Website: taifengcable.en.
We are China AAAC All Aluminum Alloy Conductor Overhead Power Aerial Bundle Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular Aerial Bundle Cable Products
PVC XLPE Insulated Duplex, Triplex, Quadruplex Cable Overhead ABC Cable
ABC Cable Aluminum Conductor Overhead Power Cable
All Kinds ABC Cable Sizes Aerial Bunched Cable with Bare Neutral Messenger
Aerial Bundle Cable 50mm2 70mm2 95mm2 Hot Sale
Distriution Overhead Aerial Bundle Aluminium Conudctor Low Voltage XLPE Cable
XLPE Cable 0.6/1kv Power Electrical Cable ABC Cable Aerial Bundle Cable ABC
Popular taifengcable Products
Kyjv Kyjvp Kyjvp2 Kyjv22 Kyjv32 Kyjvp2-22 Kyjvp22 Control Cable
Multicore XLPE Insulated PVC Sheathed Braid Shielded Copper Control Cable
Electrical Power Cable /Nyy/N2xby/Nyfgby/N2xh /U1000 R02V/N2xy/Liycy
Zr-BV Nh-BV Byj Building Wire Cable Home Use Flame Retardancy Electrical Wire
Popular Triplex Cable Products
ANSI/Icea S-76-474 600V Aluminum XLPE Insulation Triplex Service Drop ABC Clam Cable
IEC XLPE or PE Insulation 10mm2 ABC Aluminum Cable
Low Voltage Aerial Bundled Cable Triplex ABC Cable for Overhead Transmission
ABC Cable for Electric Power Transmission
Bundle Cable (JKYJ(ABC CABLE))
ACSR Conductor XLPE Insulation Triplex Aerial Bundled Cable
Popular Twisted Aluminum Cable Products
0.6/1kv Triplex Power Cable Aluminum Conductor Low Voltage Aerial Bundled Overhead Cable
NFC Cable Aerial Bundled Cable with Insulation PE/XLPE
Three Cores Twisted Aluminum Cable
Jlha1 Jlha2 Jlha3 Jlha4 AAAC All Aluminum Alloy Conductor Aerial Bundle Cable
1kv Aluminum Conductor Overhead Cable with Insulation PE/XLPE
Three Cores Twisted Service Drop Aluminum Electric Cable ABC Cable
Tags: Aerial Bundle Cable, taifengcable, Triplex Cable, Twisted Aluminum Cable
