AAAC Bare Aluminum Conductor Overhead Type Cable 16mm 25mm 35mm
AAAC Bare Aluminum Conductor Overhead Type Cable 16mm 25mm 35mm image
Get Latest Price Request a quote
Basic Info.
Product Description
Applications
Used as bare overhead conductor for primary and secondary distribution.
Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics.
Aluminum alloy gives AAAC higher resistance to corrosion than ACSR.
standard
BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008
specification
ASTM B399
Code Name | Area | Size & Stranding of ACSR with Equal Diameter | No. & Diameter of wires | Overall Diameter | Weight | Nominal Breaking Load | ||
Nominal | Actual | |||||||
MCM | mm2 | AWG or MCM | Al/Steel | mm | mm | kg/km | kN | |
Akron | 30.58 | 15.48 | 6 | 6/1 | 7/1.68 | 5.04 | 42.7 | 4.92 |
Alton | 48.69 | 24.71 | 4 | 6/1 | 7/2.12 | 6.35 | 68 | 7.84 |
Ames | 77.47 | 39.22 | 2 | 6/1 | 7/2.67 | 8.02 | 108 | 12.45 |
Azusa | 123.3 | 62.38 | 1/0 | 6/1 | 7/3.37 | 10.11 | 172 | 18.97 |
Anaheim | 155.4 | 78.65 | 2/0 | 6/1 | 7/3.78 | 11.35 | 217 | 23.93 |
Amherst | 195.7 | 99.22 | 3/0 | 6/1 | 7/4.25 | 12.75 | 273 | 30.18 |
Alliance | 246.9 | 125.1 | 4/0 | 6/1 | 7/4.77 | 14.31 | 345 | 38.05 |
Butte | 312.8 | 158.6 | 266.8 | 7/26 | 19/3.26 | 16.3 | 437 | 48.76 |
Canton | 394.5 | 199.9 | 336.4 | 7/26 | 19/3.66 | 18.3 | 551 | 58.91 |
Cairo | 465.4 | 235.8 | 397.5 | 7/26 | 19/3.98 | 19.88 | 650 | 69.48 |
Darien | 559.5 | 283.5 | 477 | 7/26 | 19/4.36 | 21.79 | 781 | 83.52 |
Elgin | 652.4 | 330.6 | 556.5 | 7/26 | 19/4.71 | 23.54 | 911 | 97.42 |
Flint | 740.8 | 375.3 | 636 | 7/26 | 37/3.59 | 25.16 | 1035 | 108.21 |
Greely | 927.2 | 469.8 | 795 | 7/26 | 37/4.02 | 28.14 | 1295 | 135.47 |
IEC 61089
Code Number | A2 Conductor | A3 Conductor | Max.D.C. Resistance of Conductor at 20ºC | ||||||||
Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | Number of Wires | Diameter of Wires | Diameter of Conductor | Approx. Weight | Rated Strength | ||
mm² | – | mm | mm | kg/km | daN | – | mm | mm | kg/km | daN | Ω/km |
16 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
25 | 7 | 2.29 | 6.87 | 78.7 | 8.49 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
40 | 7 | 2.89 | 8.67 | 125.9 | 13.58 | 7 | 2.91 | 8.73 | 127.1 | 15.1 | 0.7158 |
63 | 7 | 3.63 | 10.8 | 198.3 | 21.39 | 7 | 3.65 | 10.95 | 200.2 | 23.06 | 0.4545 |
100 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 19 | 2.79 | 13.95 | 319.3 | 37.76 | 0.2877 |
125 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
160 | 19 | 3.51 | 17.55 | 506.1 | 54.32 | 19 | 3.53 | 17.65 | 511 | 58.56 | 0.1798 |
200 | 19 | 3.93 | 19.65 | 623.7 | 67.91 | 19 | 3.95 | 19.75 | 638.7 | 73.2 | 0.1439 |
250 | 19 | 4.39 | 21.95 | 790.8 | 84.68 | 19 | 4.41 | 22.05 | 798.4 | 91.5 | 0.1151 |
315 | 37 | 3.53 | 24.71 | 998.9 | 106.95 | 37 | 3.55 | 24.85 | 1008.4 | 115.29 | 0.0916 |
400 | 37 | 3.98 | 27.86 | 1268.4 | 135.81 | 37 | 4 | 28 | 1280.5 | 146.4o | 0.0721 |
450 | 37 | 4.22 | 29.54 | 1426.9 | 152.79 | 37 | 4.24 | 29.68 | 1440.5 | 164.7 | 0.0641 |
500 | 37 | 4.45 | 31.15 | 1585.5 | 169.76 | 37 | 4.47 | 31.29 | 1600.6 | 183.oo | 0.0577 |
560 | 61 | 3.67 | 33.03 | 1778.4 | 190.14 | 61 | 3.69 | 33.21 | 1795.3 | 204.95 | 0.0516 |
630 | 61 | 3.89 | 35.01 | 2000.7 | 213.9 | 61 | 3.91 | 35.19 | 2019.8 | 230.58 | 0.0458 |
710 | 61 | 4.13 | 37.17 | 2254.8 | 241.07 | 61 | 4.15 | 37.35 | 2276.2 | 259.86 | 0.0407 |
800 | 61 | 4.38 | 39.42 | 2540.6 | 271.62 | 61 | 4.4 | 39.6 | 2564.8 | 282.8 | 0.0361 |
900 | 91 | 3.81 | 41.91 | 2861.1 | 305.58 | 91 | 3.83 | 42.13 | 2888.3 | 329.4 | 0.0321 |
1000 | 91 | 4.01 | 44.11 | 3179 | 339.53 | 91 | 4.03 | 44.33 | 3209.3 | 366 | 0.0289 |
1120 | 91 | 4.25 | 46.75 | 3560.5 | 380.27 | 91 | 4.27 | 46.97 | 3594.4 | 409.92 | 0 0258 |
1250 | 91 | 4.49 | 49.39 | 3973.7 | 424.41 | – | – | – | – |
BS EN50183
Code Name | Calculated | No..Dia.of Wires | Overall Diameter | Weight | Rated Strength |
Cross Section | |||||
mm² | No./mm | mm | kg/km | kN | |
Box | 18.8 | 7/1.85 | 5.55 | 51.4 | 5.55 |
Acacia | 23.8 | 7/2.08 | 6.24 | 64.9 | 7.02 |
Almond | 30.1 | 7/2.34 | 7.02 | 82.2 | 8.88 |
Cedar | 35.5 | 7/2.54 | 7.62 | 96.8 | 10.46 |
Deodar | 42.2 | 7/2.77 | 8.31 | 115.2 | 12.44 |
Fir | 47.8 | 7/2.95 | 8.85 | 130.6 | 14.11 |
Hazel | 59.9 | 7/3.30 | 9.9 | 163.4 | 17.66 |
Pine | 71.6 | 7/3.61 | 10.8 | 195.6 | 21.14 |
Holly | 84.1 | 7/3.91 | 11.7 | 229.5 | 24.79 |
Willow | 89.7 | 7/4.04 | 12.1 | 245,0 | 26.47 |
Oak | 118.9 | 7/4.65 | 14 | 324.5 | 35.07 |
Mulberry | 150.9 | 19/3.18 | 15.9 | 414.3 | 44.52 |
Ash | 180.7 | 19/3.48 | 17.4 | 496.1 | 53.31 |
Elm | 211 | 19/3.76 | 18.8 | 579.2 | 62.24 |
Poplar | 239.4 | 37/2.87 | 20.1 | 659.4 | 70.61 |
Sycamore | 303.2 | 37/3.23 | 22.6 | 835.2 | 89.4 |
Upas | 362.1 | 37/3.53 | 24.7 | 997.5 | 106.82 |
Yew | 479 | 37/4.06 | 28.4 | 1319.6 | 141.31 |
Totara | 498.1 | 37/4.14 | 29 | 1372.1 | 146.93 |
Rubus | 586.9 | 61/3.50 | 31.5 | 1622 | 173.13 |
Sorbus | 659.4 | 61/3.71 | 33.4 | 1822.5 | 194.53 |
Araucaria | 821.1 | 61/4.14 | 37.3 | 2269.4 | 242.24 |
Redwood | 996.2 | 61/4.56 | 41 | 2753.2 | 293.88 |
Code number | Calculated area | Number of wires | Diameter of wire | Overall diameter of conductor | Linear mass | Rated tensile strength | Max. DC resistance at 20ºC |
mm2 | mm2 | mm | mm | kg/km | daN | Ω/km | |
16 | 15.89 | 7 | 1.7 | 5.1 | 43 | 444 | 2.091 |
25 | 24.25 | 7 | 2.1 | 6.3 | 66 | 677 | 1.3703 |
35 | 34.36 | 7 | 2.5 | 7.5 | 94 | 960 | 0.9669 |
50 | 49.48 | 7 | 3 | 9 | 135 | 1382 | 0.6714 |
50 | 48.35 | 19 | 1.8 | 9 | 133 | 1350 | 0.6905 |
70 | 65.81 | 19 | 2.1 | 10.5 | 181 | 1838 | 0.5073 |
95 | 93.27 | 19 | 2.5 | 12.5 | 256 | 2605 | 0.3579 |
120 | 116.99 | 19 | 2.8 | 14 | 322 | 3268 | 0.2854 |
150 | 147.11 | 37 | 2.25 | 15.8 | 406 | 4109 | 0.2274 |
185 | 181.62 | 37 | 2.5 | 17.5 | 500 | 5073 | 0.1842 |
240 | 242.54 | 61 | 2.25 | 20.3 | 670 | 6774 | 0.1383 |
300 | 299.43 | 61 | 2.5 | 22.5 | 827 | 8363 | 0.112 |
400 | 400.14 | 61 | 2.89 | 26 | 1104 | 11176 | 0.0838 |
500 | 499.63 | 61 | 3.23 | 29.1 | 1379 | 13960 | 0.06709 |
625 | 626.2 | 91 | 2.96 | 32.6 | 1732 | 17490 | 0.054 |
800 | 802.09 | 91 | 3.35 | 36.9 | 2218 | 22402 | 0.0418 |
1000 | 999.71 | 91 | 3.74 | 41.1 | 2767 | 27922 | 0.0335 |
We are China AAAC Bare Aluminum Conductor Overhead Type Cable 16mm 25mm 35mm manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAAC Bare Aluminum Conductor Overhead Type Cable 16mm 25mm 35mm Products
Popular All Aluminum Alloy Conductor Products
Overhead 30mm 50mm 75mm AAC/AAAC/ACSR/Hda/Sca Bare Aluminum Conductor Wire Price
Aluminium Conductor Steel Reinforced/All Aluminum Alloy Conductor (ACSR AAAC AAC)
ASTM 6201 All Aluminum Alloy Conductor AAAC Cable Bare Aluminum Conductor Power Cable
Ampacity of 795 AAC Conductor Cable Bare Conductor Aluminum Conductor
Hot Sale ACSR AAC AAAC Conductor Aluminum Cable for Overhead Power Transmission Line
BS DIN IEC Standard Overhead Stranded Transmission Line AAAC AAC
Popular Bare Cable Products
Overhead Bare Aluminum Conductor Cable AAC AAAC ACSR Conductor
AAAC All Aluminium Alloy Conductor Overhead Bare Cable
ASTM Standard 477mcm 795mcm Overhead Bare Conductor, ACSR, AAC, AAAC, Aasc Conductor
AAAC Aluminum Alloy Cable 150mm 240mm Bare Aluminum Conductor
Overhead Electrical AAC Aluminum Conductor
Popular kingyear Products
400kv Low Price High Voltage 240mm XLPE Insulated PVC Sheathed Power Cable
Low Price 5205 Aluminum Plate/Sheet/Coil/Strip Full Size Available
7core Heat Resistance Silicon Rubber Cable 16AWG 22AWG General Purpose Rubber Sheathed Cable
Bright Finish AA7050 Aluminum Plate Price Per Ton
1/0AWG 2/0 AWG 3/0 AWG 4/0AWG Duplex Triplex Quadruplex Aluminum ABC Cable
Tags: AAAC Bare Aluminum Conductor Overhead Type Cable 16mm 25mm 35mm, All Aluminum Alloy Conductor, Bare Cable, kingyear