Quick Details

AAAC Conductor Amelec 34.4mm, 54.6mm, 75.5mm; , , 96.6mm, 107mm with French Standard

Zhonghua

ISO9001, CE, CCC, Kema

Round Wire

Aluminum

Overhead

Stranded

Bare

ZHONGHUA

Drum

1100*1100mm

China

8544609000

Product Details

ACSR Cable Features:
Simple structure / Easy installation and maintenance / Low circuit cost / Large transmission capacity / Good conductive performance / Sufficient mechanical strength / High tensile strength

ACSR Cable Advantage:
1. Convenient for laying across special geographical conditions such as rivers and valleys
2.The tower distance can be enlarged

ACSR Cable Application:
Widely used in overhead power transmission lines of various voltage levels

AAAC Cable Applications
AAAC Aluminum Alloy Conductor is Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high-strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. Aluminum alloy gives higher resistance to corrosion than ACSR.

Standard
 BS EN50183,IEC 61089, ASTM B399,BS 3242, DIN 48204,GB/T1179-2008

Specification
Physical contents of aluminum alloy :- 
1. Resistivity – 0.0326 Ohms mm2/m at 20°C 
2. Density – 2.70 kgm/dm3 at 20°C 
3. Coefficient of Linear Expansion – 23 x 10-6 / °C 
4. Constant Mass Temperature Coefficient (a) – 0.00360/ °C 
5. Material – Heat treated Al. Mg. Si. Alloy 
– Approximately 0.5% Mg & 0.5% Si 
 
ASTM B399

Code Name Area Size & Stranding of ACSR with Equal Diameter No. & Diameter of wires Overall Diameter Weight Nominal Breaking Load
Nominal Actual
MCM mm2 AWG or MCM Al/Steel mm mm kg/km kN
Akron 30.58 15.48 6 6/1 7/1.68 5.04 42.7 4.92
Alton 48.69 24.71 4 6/1 7/2.12 6.35 68.0 7.84
Ames 77.47 39.22 2 6/1 7/2.67 8.02 108 12.45
Azusa 123.3 62.38 1/0 6/1 7/3.37 10.11 172 18.97
Anaheim 155.4 78.65 2/0 6/1 7/3.78 11.35 217 23.93
Amherst 195.7 99.22 3/0 6/1 7/4.25 12.75 273 30.18
Alliance 246.9 125.1 4/0 6/1 7/4.77 14.31 345 38.05
Butte 312.8 158.6 266.8 26/7 19/3.26 16.30 437 48.76
Canton 394.5 199.9 336.4 26/7 19/3.66 18.30 551 58.91
Cairo 465.4 235.8 397.5 26/7 19/3.98 19.88 650 69.48
Darien 559.5 283.5 477.0 26/7 19/4.36 21.79 781 83.52
Elgin 652.4 330.6 556.5 26/7 19/4.71 23.54 911 97.42
Flint 740.8 375.3 636.0 26/7 37/3.59 25.16 1035 108.21
Greely 927.2 469.8 795.0 26/7 37/4.02 28.14 1295 135.47

 
IEC 61089

Code Number A2 Conductor A3 Conductor  Max.D.C. Resistance of Conductor at 20ºC
Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength Number of Wires  Diameter of Wires Diameter of Conductor Approx. Weight Rated Strength
mm² mm mm kg/km daN mm mm kg/km daN Ω/km
16 7 1.83 5.49 50.4 5.43 7 1.84 5.52 50.8 6.04 1.7896
25 7 2.29 6.87 78.7 8.49 7 2.30 6.9 79.5 9.44 1.1453
40 7 2.89 8.67 125.9 13.58 7 2.91 8.73 127.1 15.1 0.7158
63 7 3.63 10.8 198.3 21.39 7 3.65 10.95 200.2 23.06 0.4545
100 19 2.78 13.9 316.3 33.95 19 2.79 13.95 319.3 37.76 0.2877
125 19 3.10 15.5 395.4 42.44 19 3.12 15.6 399.2 47.20 0.2302
160 19 3.51 17.55 506.1 54.32 19 3.53 17.65 511.0 58.56 0.1798
200 19 3.93 19.65 623.7 67.91 19 3.95 19.75 638.7 73.20 0.1439
250 19 4.39 21.95 790.8 84.68 19 4.41 22.05 798.4 91.50 0.1151
315 37 3.53 24.71 998.9 106.95 37 3.55 24.85 1008.4 115.29 0.0916
400 37 3.98 27.86 1268.4 135.81 37 4.0 28 1280.5 146.4o 0.0721
450 37 4.22 29.54 1426.9 152.79 37 4.24 29.68 1440.5 164.70 0.0641
500 37 4.45 31.15 1585.5 169.76 37 4.47 31.29 1600.6 183.oo 0.0577
560 61 3.67 33.03 1778.4 190.14 61 3.69 33.21 1795.3 204.95 0.0516
630 61 3.89 35.01 2000.7 213.90 61 3.91 35.19 2019.8 230.58 0.0458
710 61 4.13 37.17 2254.8 241.07 61 4.15 37.35 2276.2 259.86 0.0407
800 61 4.38 39.42 2540.6 271.62 61 4.4 39.6 2564.8 282.80 0.0361
900 91 3.81 41.91 2861.1 305.58 91 3.83 42.13 2888.3 329.40 0.0321
1000 91 4.01 44.11 3179.0 339.53 91 4.03 44.33 3209.3 366.00 0.0289
1120 91 4.25 46.75 3560.5 380.27 91 4.27 46.97 3594.4 409.92 0 0258
1250 91 4.49 49.39 3973.7 424.41    

 
BS EN50183

Code Name  Calculated
Cross Section
No..Dia.of Wires  Overall Diameter Weight Rated Strength
  mm² No./mm mm kg/km kN
Box 18.8 7/1.85 5.55 51.4 5.55
Acacia 23.8 7/2.08 6.24 64.9 7.02
Almond 30.1 7/2.34 7.02 82.2 8.88
Cedar 35.5 7/2.54 7.62 96.8 10.46
Deodar 42.2 7/2.77 8.31 115.2 12.44
Fir 47.8 7/2.95 8.85 130.6 14.11
Hazel 59.9 7/3.30 9.90 163.4 17.66
Pine 71.6 7/3.61 10.8 195.6 21.14
Holly 84.1 7/3.91 11.7 229.5 24.79
Willow 89.7 7/4.04 12.1 245,0 26.47
Oak 118.9 7/4.65 14.0 324.5 35.07
Mulberry 150.9 19/3.18 15.9 414.3 44.52
Ash 180.7 19/3.48 17.4 496.1 53.31
Elm 211.0 19/3.76 18.8 579.2 62.24
Poplar 239.4 37/2.87 20.1 659.4 70.61
Sycamore 303.2 37/3.23 22.6 835.2 89.40
Upas 362.1 37/3.53 24.7 997.5 106.82
Yew 479.0 37/4.06 28.4 1319.6 141.31
Totara 498.1 37/4.14 29.0 1372.1 146.93
Rubus 586.9 61/3.50 31.5 1622.0 173.13
Sorbus 659.4 61/3.71 33.4 1822.5 194.53
Araucaria 821.1 61/4.14 37.3 2269.4 242.24
Redwood 996.2 61/4.56 41.0 2753.2 293.88

 
Din 48201

Code number Calculated area Number of wires Diameter of wire Overall diameter of conductor Linear mass Rated tensile strength Max. DC resistance at 20ºC
mm2 mm2   mm mm kg/km daN Ω/km
16 15.89 7 1.70 5.1 43 444 2.0910
25 24.25 7 2.10 6.3 66 677 1.3703
35 34.36 7 2.50 7.5 94 960 0.9669
50 49.48 7 3.00 9.0 135 1382 0.6714
50 48.35 19 1.80 9.0 133 1350 0.6905
70 65.81 19 2.10 10.5 181 1838 0.5073
95 93.27 19 2.50 12.5 256 2605 0.3579
120 116.99 19 2.80 14.0 322 3268 0.2854
150 147.11 37 2.25 15.8 406 4109 0.2274
185 181.62 37 2.50 17.5 500 5073 0.1842
240 242.54 61 2.25 20.3 670 6774 0.1383
300 299.43 61 2.50 22.5 827 8363 0.1120
400 400.14 61 2.89 26.0 1104 11176 0.0838
500 499.63 61 3.23 29.1 1379 13960 0.06709
625 626.20 91 2.96 32.6 1732 17490 0.0540
800 802.09 91 3.35 36.9 2218 22402 0.0418
1000 999.71 91 3.74 41.1 2767 27922 0.0335

We are China AAAC Conductor Amelec 34.4mm, 54.6mm, 75.5mm; , , 96.6mm, 107mm with French Standard manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.

Get Latest Price Request a quote

Popular AAAC Products

AAAC Bare Conductor Overhead Transmission Line Cable AAAC

Overhead Bare Aluminum Conductor AAAC 6201 to ASTM BS399

Manufacturer Supply Power Cable Bare Conductor Stranded AAAC Conductor

All Aluminium Alloy Stranded Conductor/ Bare Conductor

AAAC Tansmission and Distribution Cable Bare Conductor and AAAC

Aster Cable Almelec Conductor NFC 34 125

Popular AAAC Conductor Products

BS Standard 175mm2 Aluminum Alloy Conductor AAAC Elm Conductor

AAAC Greely 927.2mcm Bare Overhead Conductor/Overhead Transmission Line

AAC Conductor 50mm2 - Bare Aluminum Conductor

AAAC Conductor ASTM B399 Bare Aluminium Alloy 6201-T81 6AWG

AAAC Conductor (All Aluminium Alloy Conductor) Overhead Line Conductor

2AWG 6201 AAAC Aluminum Alloy Conductor

Popular Bare Conductor Products

ACAR 1200 MCM Aluminium Alloy Greased Conductor for 500kV Transmission Line

Overhead ACSR Duck Conductor Steel Wire Reinforced Electric Cable for Power Transmission

Bare Conductor Aluminium Tinned Copper Clad Strand Steel Wire

Popular Aluminum AAC AAAC Hard Drawn Standard Bare Steel Reinforced Overhead ACSR Conductor

AAC Bare Conductor 250sqmm 315sqmm 400sqmm All Aluminium Stranded Power Conductor

ACSR Wolf 150mm2 Bare Conductor 30/2.59+7/2.59mm BS EN 50182

Popular wuhancable Products

PVC Insulated Copper Wire Kvv22 Kvvp Control Cable

Copper Core All-Weather Resistance Cable for Wind Power

All Aluminium Conductor / AAC Overhead Conductor

IEC, ASTM, BS Standard AAC Conductor From Factory

Transmission and Distribution Low Voltage 0.6/1kv Aerial Bundle Cable ABC

XLPE/PVC Copper Insulated Power Cable

Tags: , , ,

FAST AND RELIABLE SERVICE FOR YOUR PROJECT

Contact our trained experts today to find your perfect power solution.

ASK A QUESTION