AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable
AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Covered line wire
Covered line wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Duplex service drop
To supply 120 volt aerial service for temporary service at construction sites, outdoorr or street lighting. For service at 600 volts or lower ar a conductor temperature of celsius 75 maximum.
Triplex service drop
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (pahse to phase) at a conductor temperature of celsius 75 maximum for polyethylene insulation or celsius 90 maximum for crosslinked insulation.
Quadruplex service drop
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltage of 600 volts or less phase to phase and at conductor temperature no to exceed celsius 75 for polyethylene insulated conductor or celsius 90 for crosslinked polyethylene insulated conductors.
Construction
Concentric strand or compressed 1350-H19 oncductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards
ASTM B-230, B-231
ICEA S-76-474
| Core* Section area mm 2 | Number of core/diameter mm | Thickness of the insulation |
The resistance of the conductor at 20°C ≤Ω/km | Reference weight kg/km | |
| Main core | The fourth core | ||||
| 3*4+1*2.5 | 1/2.25+1/1.78 | 1.0 | 1.0 | 7.41 | 48.3 |
| 3*6+1*4 | 1/2.76+1/2.25 | 1.0 | 1.0 | 4.61 | 95.5 |
| 3*10+1*6 | 7/1.35+1/2.76 | 1.0 | 1.0 | 3.08 | 141.2 |
| 3*16+1*10 | 7/1.70+7/1.35 | 1.2 | 1.2 | 1.91 | 215.3 |
| 3*25+1*16 | 7/2.14+7/1.70 | 1.2 | 1.2 | 1.20 | 289.1 |
| 3*35+1*25 | 7/2.52+7/2.14 | 1.2 | 1.2 | 0.868 | 382.4 |
| 3*50+1*35 | 7/3.00+7/2.52 | 1.4 | 1.4 | 0.614 | 526.0 |
| 3*70+1*50 | 19/2.14+7/3.00 | 1.4 | 1.4 | 0.443 | 655.0 |
| 3*95+1*70 | 19/2.52_19/2.14 | 1.6 | 1.6 | 0.320 | 886.6 |
| 3*120+1*95 | 37/2.03+19/2.52 | 1.6 | 1.6 | 0.253 | 1075.7 |
| 3*150+1*120 | 37/2.52+37/2.03 | 1.8 | 1.8 | 0.206 | 1320.8 |
We are China AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 11kv ABC Cable Products
11kv ABC Cable Aerial Bundled Cable with IEC60502 Standard
High Voltage Al/XLPE 11kv ABC Cable, Malemute
Aluminum Alloy Strand Conductor AAC/ACSR Conductor Twisted ABC Cable
11kv ABC Aluminium Overhead Cable by Manumfactory of Henan Jinshui Cable
11kv ABC Cable/Service Drop Wire
Triplex Service Drop Aerial Cable
Popular Electirc Cable Products
Overhead ABC Conductors Triplex Service Drop Power Cable
Triplex Service Drop Aerial Cable
Triplex Service Drop Electirc Aerial Cable
Aluminum Alloy XLPE Insulation Service Entrance Cable 6 AWG Aluminum Concentric Cable 2X6mm2 Price
2AWG 3core Aluminum XLPE PVC Electric Distribute Power Cable
Popular Henan Cable Products
Overhead ABC Conductors Triplex Service Drop Cable
0.6/1kv Aluminium XLPE Insulated Aerial Bundle Service Drop Cables
Overhead ABC Conductors Triplex Service Drop Power Cable
Triplex Service Drop Electirc Aerial Cable
Quadruplex Service Drop Cable / ABC Cable / Aerial Bundled Cable
Quadruplex Service Drop Cable Aluminum Conductor Aerial Bundled Overhead Cables
Popular jsgroup Products
Uesd for Overhead Service Application for Street Linghting
0.6/1kv Overhead Aluminum Conductor PE Insulated Power Cables
AAC Conductor XLPE/PE Insulated Cable Drum Packing
PVC Rubber Insulated Water Cooled Welding Cable
All Aluminum Bare Conductor AAC 400m2 Price Overhead Line Conductor
Tags: 11kv ABC Cable, Electirc Cable, Henan Cable, jsgroup