AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable
AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable image
Get Latest Price Request a quote
Quick Details
Product Details
Covered line wire
Covered line wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
Duplex service drop
To supply 120 volt aerial service for temporary service at construction sites, outdoorr or street lighting. For service at 600 volts or lower ar a conductor temperature of celsius 75 maximum.
Triplex service drop
To supply power from the utility’s lines to the consumer’s weatherhead. For service at 600 volts or less (pahse to phase) at a conductor temperature of celsius 75 maximum for polyethylene insulation or celsius 90 maximum for crosslinked insulation.
Quadruplex service drop
Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltage of 600 volts or less phase to phase and at conductor temperature no to exceed celsius 75 for polyethylene insulated conductor or celsius 90 for crosslinked polyethylene insulated conductors.
Construction
Concentric strand or compressed 1350-H19 oncductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards
ASTM B-230, B-231
ICEA S-76-474
Core* Section area mm 2 | Number of core/diameter mm | Thickness of the insulation |
The resistance of the conductor at 20°C ≤Ω/km | Reference weight kg/km | |
Main core | The fourth core | ||||
3*4+1*2.5 | 1/2.25+1/1.78 | 1.0 | 1.0 | 7.41 | 48.3 |
3*6+1*4 | 1/2.76+1/2.25 | 1.0 | 1.0 | 4.61 | 95.5 |
3*10+1*6 | 7/1.35+1/2.76 | 1.0 | 1.0 | 3.08 | 141.2 |
3*16+1*10 | 7/1.70+7/1.35 | 1.2 | 1.2 | 1.91 | 215.3 |
3*25+1*16 | 7/2.14+7/1.70 | 1.2 | 1.2 | 1.20 | 289.1 |
3*35+1*25 | 7/2.52+7/2.14 | 1.2 | 1.2 | 0.868 | 382.4 |
3*50+1*35 | 7/3.00+7/2.52 | 1.4 | 1.4 | 0.614 | 526.0 |
3*70+1*50 | 19/2.14+7/3.00 | 1.4 | 1.4 | 0.443 | 655.0 |
3*95+1*70 | 19/2.52_19/2.14 | 1.6 | 1.6 | 0.320 | 886.6 |
3*120+1*95 | 37/2.03+19/2.52 | 1.6 | 1.6 | 0.253 | 1075.7 |
3*150+1*120 | 37/2.52+37/2.03 | 1.8 | 1.8 | 0.206 | 1320.8 |
We are China AAC/ACSR/AAAC XLPE/PE Insulated Aerial Bunded Cable manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular 11kv ABC Cable Products
Quadruplex Service Drop Cable / ABC Cable / Aerial Bundled Cable
Quadruplex Service Drop Cable / ABC Cable / Aerial Bundled Cable
11kv Overhead Application ABC Cable Power Cable
6.35/11kV Aluminium Conductor AL ABC 3Cx150+50mm2 XLPE Insulated Aerial Bundled Cable
11kv ABC Cable 3 Core Aerial Bundled Cable
(ABC) 11kv Duplex/Triplex/Quadruplex Service Drop Aluminium Conductor
Popular Electirc Cable Products
Triplex Service Drop Electirc Aerial Cable
Triplex Service Drop Aerial Cable
2AWG 3core Aluminum XLPE PVC Electric Distribute Power Cable
XLPE Insulated Aerial Bundle Service Drop Cable
Overhead ABC Conductors Triplex Service Drop Cable
Quadruplex Service Drop Cable / ABC Cable / Aerial Bundled Electrical Cable
Popular Henan Cable Products
Overhead ABC Conductors Triplex Service Drop Power Cable
Triplex Service Drop Aerial Cable
Triplex Service Drop Electirc Aerial Cable
Overhead ABC Conductors Triplex Service Drop Cable
XLPE Insulated Aerial Bundle Service Drop Cable
Quadruplex Service Drop Cable / ABC Cable / Aerial Bundled Cable
Popular jsgroup Products
Copper Conductor, PVC Insulated and Sheathed Control Cable
#6 AWG ABC Cable / Duplex Drop Service
XLPE Armoured Power AC Electric Power Cable
Low Voltage Power Single Core Multi-Core XLPE Cable
0.6/1kv 4 Core Copper Conductor PVC Insulation Armoured Copper Cable
Tags: 11kv ABC Cable, Electirc Cable, Henan Cable, jsgroup