AAC Conductor All Aluminium Bare Conductor
AAC Conductor All Aluminium Bare Conductor image
Get Latest Price Request a quote
Quick Details
Product Details
AAC Conductor All Aluminium Conductor overhead cable Construction :
AAC is stranded concentrically by aluminium wires with same nominal diameter.
AAC Conductor All Aluminium Conductor overhead cable Application :
The AAC is suitable for power transmission and distribution for short span, such as low voltage lines, linking bridges between the deadend clamps of the high voltage lines, high voltage busbars at substations.
AAC Conductor All Aluminium Conductor overhead cable Operating Temperature:
Max permissible continuous operating temperature of conductor shall not exceed 80°C.
AAC Conductor All Aluminium Conductor overhead cable Standard:
ASTM B231, BS 215, DIN 48201, IEC 61089, GB/T 1179 or other standards required by customers
AAC Conductor All Aluminium Conductor overhead cable Technical Data:
Numbers of Wires | Final Modules of Elasticity | Coeficient of linear Expansion | ||
AL | Kg/mm2 | lb/in2 | 1/Co | 1/Fo |
7 | 6000 | 8.5 x106 | 23.0 x10-6 | 112.8 x10-6 |
19 | 5700 | 8.1 x106 | 23.0 x10-6 | 112.8 x10-6 |
37 | 5700 | 8.1 x106 | 23.0 x10-6 | 112.8 x10-6 |
61 | 5500 | 7.8 x106 | 23.0 x10-6 | 112.8 x10-6 |
91 | 5500 | 7.8 x106 | 23.0 x10-6 | 112.8 x10-6 |
AAC British Standard BS 215 – Part 1
Code | Nominal Area | Stranding | Overall Diameter | Weight | Rated Strength | Electrical Resistance | Current Rating | |
Nominal | theoretical | |||||||
mm2 | mm2 | No.×mm | mm | kg/km | KN | Ω/Km | A | |
Gnat | 25 | 26.9 | 7/2.21 | 6.63 | 73 | 4.83 | 1.0643 | 115 |
Mosquito | 35 | 36.9 | 7/2.59 | 7.77 | 101 | 6.27 | 0.7749 | 140 |
Ladybird | 40 | 42.8 | 7/2.79 | 8.37 | 117 | 7.28 | 0.6678 | 154 |
Bluebottle | 70 | 73.6 | 7/3.66 | 10.98 | 201 | 11.78 | 0.388 | 215 |
Earwig | 75 | 78.6 | 7/3.78 | 11.34 | 215 | 12.57 | 0.3638 | 223 |
Grasshopper | 80 | 84.1 | 7/3.91 | 11.73 | 230 | 13.45 | 0.34 | 233 |
Clegg | 90 | 95.6 | 7/4.17 | 12.51 | 261 | 15.3 | 0.2989 | 252 |
Beetle | 100 | 106.4 | 19/2.67 | 13.35 | 292 | 18.08 | 0.2701 | 269 |
Bee | 120 | 132 | 7/4.90 | 14.7 | 361 | 21.12 | 0.2165 | 307 |
Caterpillar | 180 | 185.9 | 19/3.53 | 17.65 | 511 | 29.75 | 0.1546 | 379 |
Spider | 220 | 237.6 | 19/3.99 | 19.95 | 653 | 38.01 | 0.121 | 440 |
Moth | 350 | 373.1 | 19/5.00 | 25 | 1025 | 59.69 | 0.077 | 579 |
Drone | 350 | 372.4 | 37/3.58 | 25.06 | 1027 | 59.59 | 0.0774 | 577 |
Maybug | 450 | 486.1 | 37/4.09 | 28.63 | 1341 | 77.78 | 0.0593 | 677 |
Scorpion | 500 | 529.8 | 37/4.27 | 29.89 | 1461 | 84.77 | 0.0544 | 713 |
Cicada | 600 | 628.3 | 37/4.65 | 32.55 | 1733 | 100.54 | 0.0459 | 788 |
Note: *The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.
AS 1531 Australia Standard
Code Name | Stranding and wire diameter | Cross- sectional area | Approximate mass | Calculated breaking load (CBL) | Equiv. aluminium area | DC resist. at 20°C |
mm | mm2 | kg/km | kN | mm2 | Ω/km | |
Leo | 7.5 | 34.36 | 94.3 | 5.71 | 33.9 | 0.833 |
Leonids | 8.25 | 41.58 | 113 | 6.72 | 41.1 | 0.689 |
Libra | 9.0 | 49.48 | 135 | 7.98 | 48.9 | 0.579 |
Mars | 11.3 | 77.28 | 211 | 11.8 | 76.3 | 0.370 |
Mercury | 13.5 | 111.3 | 304 | 16.9 | 110 | 0.258 |
Moon | 14.3 | 124.0 | 339 | 18.9 | 122 | 0.232 |
Neptune | 16.3 | 157.6 | 433 | 24.7 | 154 | 0.183 |
Orion | 17.5 | 182.8 | 503 | 28.7 | 180 | 0.157 |
Pluto | 18.8 | 209.8 | 576 | 31.9 | 206 | 0.137 |
Saturn | 21.0 | 261.6 | 721 | 42.2 | 256 | 0.110 |
Sirius | 22.8 | 307.0 | 845 | 48.2 | 301 | 0.094 |
Taurus | 23.8 | 336.7 | 924 | 51.3 | 331 | 0.0857 |
Triton | 26.3 | 408.5 | 1120 | 62.2 | 400 | 0.0706 |
Uranus | 29.3 | 506.1 | 1400 | 75.2 | 495 | 0.0572 |
Ursula | 31.5 | 586.9 | 1620 | 87.3 | 574 | 0.0493 |
Venus | 33.8 | 673.4 | 1860 | 97.2 | 659 | 0.0429 |
We are China AAC Conductor All Aluminium Bare Conductor manufacture and supplier,You can get more details with Email,you will get cheap price or factory price.
Get Latest Price Request a quote
Popular AAC Products
All Aluminum Conductor (AAC) &Aluminum Conductor Steel Reinforced (ACSR)
ASTM B399 Standard AAAC AAC ACSR Cable Conductor
Almelec Cable Flint 750mcm ASTM B399
AAC Conductor DIN ASTM IEC BS Standard
Overhead Transmission Line Aluminium Stranded Conductor AAC
ASTM Standard AWG Size Bare Aluminium Conductor AAC
Popular Aluminium Conductors Products
Aluminium Conductors AAC ACSR AAAC Acar Bare Conductor
Overhead Power Line Conductor AAC Cable Lupine 91/4.21mm
AAC AAAC ACSR Overhead Transmission Line Bare Aluminium Conductors
ACSR Aluminium Conductor Galvanized Steel Reinforced Overhead Conductor
Popular Conductors Products
ACSR ASTM Standard of AAC/AAAC/ACSR/Aacsr/ Bare Conductor
Bare Aluminum Conductor Steel Reinforced Swan 4AWG
ACSR Conductor Aluminium Conductors Steel Reinforced Cable
Power Transmission Lines AAC/AAAC/ACSR/Aacsr/ Bare Conductor
ACSR Conductor with ASTM Standard 1200mcm
Popular jinlingcable Products
Secondary Circuit Cable 450/750V to ADP Airport Cable
Nayy Aluminum Conductor XLPE Insulated PVC Electric Wire Power Cable
5kv 8kv XLPE Insulation 100% 133% Aia Armored Mv90 Medium Voltage Power Cable Interlock Cables
Ptta 600V Flexible Low Voltage Control and Power Cables
600V Airport Pavement Cable Airfield Lighting Nylon Cables
Nyby PVC Insulated Steel Tape Armored Control Cable
Tags: AAC, Aluminium Conductors, Conductors, jinlingcable